1SDA054097R1 ABB T4V250 PR221DS-I 160A 3P Fixed Front Circuit Breaker

1SDA054097R1 ABB T4V250 PR221DS-I 160A 3P Fixed Front Circuit Breaker

ABB 1SDA054097R1 is a fixed three-pole 160 A SACE Tmax T4V250 moulded case circuit breaker with a PR221DS-I electronic trip unit providing instantaneous short-circuit protection.

SKU: 1SDA054097R1MPN: 1SDA054097R1
Price
List Price £2,717.73 ex VAT
Your Price (ex VAT) Save 25%
£2,038.30 25% OFF
You save £679.43 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,038.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,038.30

Why Choose the ABB 1SDA054097R1 T4V250 PR221DS-I Circuit Breaker?

The ABB 1SDA054097R1 is a SACE Tmax T4V250 moulded case circuit breaker designed for switching and short-circuit protection in demanding low-voltage power distribution systems. ABB identifies this configuration as T4V250PR221DS-IIn=1603pFF, combining the high-performance T4V frame with a rated current of 160 A and three-pole construction.

The breaker is equipped with an ABB PR221DS-I electronic trip unit, providing instantaneous short-circuit protection. The I protection function is intended to respond rapidly to severe fault currents, making this configuration suitable for applications where instantaneous protection is required and overload protection is coordinated separately.

Configured as a fixed breaker with front terminals, the 1SDA054097R1 provides a practical format for permanent installation in switchboards, distribution panels and OEM assemblies. Its T4V performance level, 160 A rating and electronic instantaneous protection make it suitable for professional industrial and commercial distribution applications.

Key Advantages

  • 160 A rated current for low-voltage distribution applications.
  • PR221DS-I electronic trip unit for instantaneous short-circuit protection.
  • High-performance T4V250 breaker platform.
  • Three-pole construction for suitable three-phase circuits.
  • Fixed execution for permanent switchboard installation.
  • Front terminals provide accessible main-circuit connections.
  • Original ABB SACE Tmax breaker for professional power distribution systems.

Key Features

  • ABB SACE Tmax T4V250 moulded case circuit breaker.
  • Rated current of 160 A.
  • 3-pole construction.
  • PR221DS-I electronic trip unit.
  • Instantaneous (I) protection function.
  • Fixed breaker execution.
  • Front main-circuit terminals.
  • Designed for low-voltage switching and short-circuit protection.
  • Original ABB order code 1SDA054097R1.

Electronic Instantaneous Protection for High Fault Currents

The PR221DS-I trip unit provides electronic instantaneous protection designed to trip the circuit breaker rapidly when current reaches a severe short-circuit level. This protection characteristic helps limit the duration of high fault currents in correctly engineered low-voltage distribution systems.

The ABB 1SDA054097R1 combines this protection function with the T4V250 breaker platform and a 160 A rated current. Its fixed three-pole construction and front connections support straightforward integration into compatible switchboards and power distribution assemblies.

Typical Applications

  • Industrial low-voltage power distribution.
  • Three-phase feeder circuits.
  • Main and sub-distribution switchboards.
  • Circuits requiring instantaneous short-circuit protection.
  • Industrial machinery and electrical panels.
  • Commercial electrical distribution systems.
  • OEM switchgear and power distribution assemblies.

Technical Specifications

Product family SACE Tmax
Frame / performance level T4V250
ABB order code 1SDA054097R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 160 A
Number of poles 3
Trip unit PR221DS-I
Protection function I
Instantaneous protection (I) Yes
Installation Fixed
Terminal arrangement Front
Product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the rated current of the ABB 1SDA054097R1?

The ABB 1SDA054097R1 has a rated current of 160 A.

Which trip unit is fitted to the ABB 1SDA054097R1?

The circuit breaker is equipped with an ABB PR221DS-I electronic trip unit.

What protection does the ABB 1SDA054097R1 provide?

The PR221DS-I configuration provides instantaneous (I) short-circuit protection for rapid response to high fault currents.

How many poles does the ABB 1SDA054097R1 have?

The ABB 1SDA054097R1 is a three-pole moulded case circuit breaker for suitable three-phase applications.

What installation configuration does the ABB 1SDA054097R1 use?

The ABB designation specifies a fixed breaker with front terminals, making it suitable for permanent installation in compatible switchboards.

Trusted ABB Low-Voltage Circuit Protection

ABB SACE Tmax moulded case circuit breakers combine compact construction, dependable switching and electronic protection technology for professional low-voltage power distribution and industrial switchgear applications.