1sda054007r1  t4n 250 pr222ds/p-lsig in=160 3 pole abb mccb

1sda054007r1 t4n 250 pr222ds/p-lsig in=160 3 pole abb mccb

ABB 1SDA054007R1 SACE Tmax T4N 250 moulded case circuit breaker with PR222DS/P-LSIG electronic trip unit, 160 A rated current and fixed three-pole front terminal configuration for industrial low voltage power distribution.

SKU: 1SDA054007R1Alt SKU: T4N 250 PR222DS/P-LSIG In=160 3p F FMPN: 1SDA054007R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA054007R1 Tmax T4N 250 MCCB?

The ABB 1SDA054007R1 is a high-performance Tmax T4N moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage electrical distribution systems. As part of the trusted ABB SACE Tmax T series, this breaker combines robust construction with an advanced electronic trip unit, making it ideal for industrial switchboards, commercial installations and OEM machinery.

This model is fitted with the PR222DS/P-LSIG electronic trip unit, providing adjustable long-time, short-time, instantaneous and ground fault protection. These advanced protection functions improve system selectivity, minimise unnecessary downtime and help safeguard valuable electrical assets.

With a 160 A rated current, T4N 250 frame size and a 36 kA breaking capacity at 415 V AC, the ABB 1SDA054007R1 is ideally suited to feeder protection, motor control centres, industrial machinery and commercial power distribution applications requiring comprehensive circuit protection.

Key Advantages

  • High quality ABB SACE Tmax T4N moulded case circuit breaker.
  • 160 A rated current for industrial and commercial distribution.
  • PR222DS/P-LSIG electronic trip unit with advanced protection.
  • Ground fault protection improves electrical safety.
  • Three-pole fixed breaker with front terminals.
  • Designed for demanding low voltage power distribution systems.

Key Features

  • ABB SACE Tmax T series.
  • T4N 250 frame size.
  • 160 A rated current.
  • PR222DS/P-LSIG electronic trip unit.
  • LSIG protection functions.
  • Three-pole fixed configuration.
  • Front terminal connection.
  • Designed to IEC 60947 standards.

Advanced Protection for Critical Power Distribution

The ABB Tmax T4N range is engineered to interrupt overloads and fault currents rapidly while maintaining reliable operation of low voltage electrical systems. The integrated PR222DS/P-LSIG electronic release provides flexible protection settings together with ground fault protection, helping improve system reliability and electrical safety.

Whether protecting industrial switchboards, machinery, motor control centres or commercial infrastructure, the ABB 1SDA054007R1 delivers dependable performance, accurate protection and the long-term reliability expected from ABB circuit protection products.

Typical Applications

  • Industrial switchboards.
  • Commercial electrical distribution.
  • Motor control centres.
  • Machine control panels.
  • OEM electrical equipment.
  • Infrastructure and utility installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 160 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T4N 250 PR222DS/P-LSIG
SKU 1SDA054007R1
EAN 8015644550936
Product type Moulded Case Circuit Breaker (MCCB)
Rated current (In) 160 A
Frame size T4N 250
Trip unit PR222DS/P-LSIG electronic release
Protection functions Long-time, Short-time, Instantaneous and Ground fault (LSIG)
Number of poles 3
Mounting type Fixed
Terminal type Front terminals
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated service breaking capacity (Ics) 36 kA at 415 V AC
Rated ultimate breaking capacity (Icu) 36 kA at 415 V AC
Dimensions (W × H × D) Approx. 105 × 205 × 103.5 mm
Weight Approx. 3.5 kg
Protection rating IP20
Standard IEC 60947

Frequently Asked Questions

What is the ABB 1SDA054007R1 used for?

It protects low voltage electrical systems against overloads, short circuits and ground faults in industrial and commercial installations.

What is the rated current of this MCCB?

The ABB 1SDA054007R1 has a 160 A rated current.

What trip unit is fitted?

This breaker uses an ABB PR222DS/P-LSIG electronic trip unit with long-time, short-time, instantaneous and ground fault protection.

How many poles does this breaker have?

This model is supplied as a fixed three-pole moulded case circuit breaker.

Where is this MCCB typically installed?

It is commonly installed in industrial switchboards, distribution panels, motor control centres and commercial electrical systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted worldwide by panel builders, electrical contractors and industrial engineers for dependable protection, advanced electronic trip technology and long-term reliability.