1sda053998r1  t4n 250 pr221ds-ls/i in=160 3 pole abb mccb

1sda053998r1 t4n 250 pr221ds-ls/i in=160 3 pole abb mccb

ABB 1SDA053998R1 SACE Tmax T4N 250 moulded case circuit breaker with PR221DS-LS/I electronic release, 160 A rated current, three-pole fixed configuration and front terminals for low voltage power distribution.

SKU: 1SDA053998R1Alt SKU: T4N 250 PR221DS-LS/I In=160 3p F FMPN: 1SDA053998R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA053998R1 SACE Tmax T4N MCCB?

The ABB 1SDA053998R1 is a reliable SACE Tmax T4N moulded case circuit breaker (MCCB) designed for overload and short-circuit protection in low voltage electrical distribution systems. As part of ABB’s trusted Tmax T circuit breaker range, this fixed three-pole breaker provides dependable electronic protection for industrial, commercial and panel building applications.

This MCCB is fitted with a PR221DS-LS/I solid-state electronic release, offering long-time, short-time and instantaneous protection functions for improved selectivity and circuit coordination. Its fixed design with front terminals supports straightforward installation in switchboards, distribution boards, control panels and low voltage power assemblies.

With a rated current of 160 A, a 690 V AC rated operational voltage and an ABB Tmax T4N frame, the ABB 1SDA053998R1 is well suited to installations requiring compact, robust and accurate circuit protection.

Key Advantages

  • Reliable ABB SACE Tmax T4N moulded case circuit breaker.
  • 160 A rated current for protected low voltage distribution circuits.
  • Three-pole fixed configuration for three-phase applications.
  • PR221DS-LS/I electronic trip unit for long-time, short-time and instantaneous protection.
  • Front terminal connection for straightforward panel installation.
  • Compact T4 frame design for efficient switchboard integration.

Key Features

  • ABB SACE Tmax T series.
  • T4N 250 frame moulded case circuit breaker.
  • 160 A rated current.
  • Three-pole fixed breaker.
  • PR221DS-LS/I solid-state electronic release.
  • 690 V AC rated operational voltage.
  • Front terminal connection.
  • Designed for industrial and commercial low voltage power distribution.

Electronic Protection for Low Voltage Distribution

Moulded case circuit breakers such as the ABB 1SDA053998R1 are used to disconnect electrical circuits during overload or fault conditions, helping protect cables, switchgear, machinery and downstream equipment from damage. The T4N frame provides dependable fault interruption performance in a compact breaker format.

The PR221DS-LS/I electronic release supports long-time, short-time and instantaneous protection, helping engineers improve selectivity and coordination across low voltage distribution systems. This makes the breaker suitable for installations where protection accuracy, compact panel design and reliable operation are essential.

Typical Applications

  • Industrial low voltage switchboards.
  • Commercial power distribution panels.
  • Electrical control panels and feeder circuits.
  • Motor control centres and machinery panels.
  • Building services electrical installations.
  • Transformer, generator and distribution circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 160 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T4N 250 PR221DS-LS/I In=160 3p F F
SKU 1SDA053998R1
EAN 8015644550646
Product type Moulded case circuit breaker
Frame size T4
Sub-type T4N
Rated current 160 A
Rated uninterrupted current 250 A
Number of poles 3
Trip unit PR221DS-LS/I
Release type Electronic / solid-state
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated frequency 50 / 60 Hz
Breaking capacity 36 kA at 415 V AC
Terminal type Front terminals
Mounting version Fixed
Standard IEC 60947
Dimensions (H × W × D) 205 × 105 × 103.5 mm
Weight approx. 3.5 kg

Frequently Asked Questions

What is the ABB 1SDA053998R1 used for?

The ABB 1SDA053998R1 is used to protect low voltage electrical circuits against overloads and short circuits in industrial and commercial power distribution systems.

What current rating does this MCCB have?

This ABB Tmax T4N MCCB has a rated current of 160 A.

How many poles does the ABB 1SDA053998R1 have?

The ABB 1SDA053998R1 is a three-pole fixed moulded case circuit breaker.

What type of trip unit is fitted?

This breaker is fitted with a PR221DS-LS/I electronic trip unit, providing long-time, short-time and instantaneous protection functions.

Where is this MCCB typically installed?

It is typically installed in low voltage switchboards, distribution panels, electrical control panels and industrial power assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by panel builders, electrical engineers and industrial maintenance teams for reliable protection, compact installation and dependable low voltage power distribution performance.