Mersen NH42GTR160KVA-8 DIN NH4A gTr transformer protection fuse link rated at 231 A and 400 V AC for 160 kVA distribution transformers with live gripping lugs and a top-mounted indicator.

SKU: NH42GTR160KVA-8Alt SKU: NH42GTR160KVA-8MPN: N1030481
Price
List Price £178.53 ex VAT
Your Price (ex VAT) Save 40%
£107.12 40% OFF
You save £71.41 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £107.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£107.12

Why Choose the Mersen NH42GTR160KVA-8 Transformer Protection Fuse Link?

The Mersen NH42GTR160KVA-8 is a high-performance DIN NH gTr fuse link engineered specifically for protecting low-voltage distribution transformers. Designed with a dedicated gTr operating characteristic, it delivers dependable overload and short-circuit protection while allowing the high magnetising inrush currents that occur during normal transformer energisation.

As part of the trusted Mersen NH gTr 400 V AC fuse-link range, this NH4A fuse link features a robust ceramic body, live gripping lugs and a top-mounted blown-fuse indicator. These features simplify maintenance while ensuring reliable performance in demanding industrial and commercial power distribution systems.

With a 160 kVA transformer rating, 231 A rated current and a 400 V AC operating voltage, the NH42GTR160KVA-8 is ideally suited to transformer feeders, industrial switchboards, commercial electrical installations and low-voltage substations requiring dependable transformer protection.

Key Advantages

  • Purpose-designed DIN NH4A gTr transformer protection fuse link.
  • Suitable for 160 kVA distribution transformers.
  • 231 A rated current.
  • 400 V AC rated voltage.
  • gTr characteristic optimised for transformer protection.
  • Top-mounted blown-fuse indicator for rapid maintenance.
  • Live gripping lugs for safer fuse replacement.

Key Features

  • Mersen NH gTr transformer fuse-link range.
  • NH4A fuse size.
  • 160 kVA transformer rating.
  • 231 A rated current.
  • 400 V AC rated operating voltage.
  • gTr transformer protection characteristic.
  • Top-mounted blown-fuse indicator.
  • Live gripping lugs.
  • 73 mm body width.
  • Heavy-duty ceramic body with DIN NH blade contacts.

Reliable Protection for Distribution Transformers

Mersen gTr fuse links are specifically engineered to protect distribution transformers by matching their operating characteristics. They permit normal transformer energisation currents while rapidly interrupting overloads and short-circuit faults, helping protect transformer windings and associated electrical equipment.

The NH42GTR160KVA-8 is widely used in transformer incomers, industrial switchboards, commercial buildings and low-voltage substations where dependable transformer protection and coordinated fault clearance are essential.

Typical Applications

  • 160 kVA distribution transformers.
  • Transformer incomers and feeders.
  • Industrial switchboards.
  • Commercial power distribution.
  • Low-voltage substations.
  • Industrial control panels.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Visual indicator
Current 231 A
Voltage 400 V
Device Type Fuse link
Fuse Type NH (DIN)
Fuse Size NH4a
Fuse Class gTr
Manufacturer Mersen
Series NH gTr 400 V AC Fuse Links
Model NH42GTR160KVA-8
Manufacturer part number N1030481
Product type NH transformer protection fuse link
Fuse characteristic gTr
Fuse size NH4A
Transformer rating 160 kVA
Rated current 231 A
Rated operating voltage 400 V AC
Current type AC
Body width 73 mm
Indicator Top indicator
Gripping lugs Live gripping lugs
Weight Approx. 2.2 kg
EAN 3605340535075
RoHS compliant Yes

Frequently Asked Questions

What is the Mersen NH42GTR160KVA-8 used for?

This fuse link is designed specifically to protect 160 kVA low-voltage distribution transformers against overload and short-circuit faults.

What transformer size is this fuse designed for?

The NH42GTR160KVA-8 is intended for transformers with a nominal rating of 160 kVA.

What is the rated current of this fuse?

The NH42GTR160KVA-8 has a 231 A rated current.

What does the gTr characteristic provide?

The gTr characteristic is optimised for transformer protection, allowing normal energisation currents while providing dependable protection against overloads and short circuits.

What type of indicator does this fuse link have?

This fuse incorporates a top-mounted blown-fuse indicator to simplify inspection and maintenance.

Trusted by Electrical Professionals Worldwide

Mersen NH gTr transformer fuse links are trusted by utilities, OEMs, panel builders and industrial electrical engineers for reliable transformer protection across demanding low-voltage power distribution systems.