Mersen NH4A2GTR1000KVA NH4a gTr transformer protection fuse-link rated at 1443 A and 400 V AC for transformer applications around 1000 kVA, with a centre indicator and 100 kA breaking capacity.
£129.75
The Mersen NH4A2GTR1000KVA is a heavy-duty NH4a gTr fuse-link developed specifically for the protection of low-voltage distribution transformers. Its transformer-matched time-current characteristic provides dependable protection against overloads and short-circuit faults while accommodating the temporary magnetising inrush current produced when a transformer is energised.
Designed for transformer applications rated at approximately 1000 kVA, this fuse-link has a rated current of 1443 A and an operating voltage of 400 V AC. The gTr characteristic supports effective selectivity with downstream gG fuse-links, helping isolate faults at the correct point while reducing unnecessary interruption to the wider electrical installation.
The NH4A2GTR1000KVA combines a durable ceramic body with silver-plated copper blade contacts, live gripping lugs and a centre-mounted visual indicator. Its 100 kA AC breaking capacity provides reliable interruption of high prospective fault currents in industrial switchboards, transformer substations and commercial power distribution systems.
Transformers can draw a substantial magnetising current for a short period when first energised. A conventional fuse selected only according to normal operating current may operate unnecessarily during this inrush period. The gTr characteristic of the Mersen NH4A2GTR1000KVA is specifically adapted to transformer behaviour, helping it withstand permissible temporary current peaks while still responding accurately to sustained overloads.
The fuse-link also provides high current limitation and effective coordination with downstream protection. When a significant fault occurs, its high breaking capacity allows it to safely interrupt the circuit, helping protect transformers, cables, switchgear and other valuable distribution equipment.
Tick the specs you need, then view products that match.
| Current | 1443 A | |
|---|---|---|
| Voltage | 400 V | |
| Device Type | Fuse link | |
| Fuse Type | NH (DIN) | |
| Fuse Size | NH4a | |
| Fuse Class | gTr | |
| Manufacturer | Mersen | |
| Series | NH Fuse-Links gTr 400 V AC | |
| Model | NH4A2GTR1000KVA | |
| Manufacturer part number | L1030525 | |
| Product type | Transformer protection fuse-link | |
| Operating class | gTr | |
| Fuse size | NH4a | |
| Nominal transformer application | 1000 kVA | |
| Rated current | 1443 A | |
| Rated voltage | 400 V AC | |
| Current type | AC | |
| Maximum AC breaking capacity | 100 kA | |
| Indicator system | Yes | |
| Indicator type | Centre indicator | |
| Gripping lug design | Live tags | |
| Terminal type | Plain blades | |
| Terminal material | Silver-plated copper | |
| Body material | Ceramic | |
| Mounting type | Clip / NH fuse-base mounting | |
| Body width | 98 mm | |
| Dimensions (L × W × H) | approx. 200 × 98 × 122 mm | |
| Power dissipation at rated current | 108 W | |
| Product weight | approx. 2.2 kg | |
| EAN / UPC | 3605340535587 | |
| RoHS compliant | Yes | |
| HS Code | 85361090 | |
| Country of Manufacture | Hungary |
The NH4A2GTR1000KVA is a gTr fuse-link designed to protect low-voltage distribution transformers against overloads and short-circuit faults.
This model is intended for transformer applications rated at approximately 1000 kVA.
The Mersen NH4A2GTR1000KVA has a rated current of 1443 A, a rated voltage of 400 V AC and a maximum AC breaking capacity of 100 kA.
gTr identifies a full-range fuse-link with a time-current characteristic specifically adapted to transformer protection. It helps tolerate normal transformer energisation currents while providing protection against overloads and short circuits.
Yes. It incorporates a centre-mounted visual indicator that helps identify when the fuse-link has operated.
Mersen NH gTr fuse-links are widely specified by electrical engineers, panel builders and industrial operators for reliable transformer protection, high fault interruption performance and coordinated operation within low-voltage power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.