MERSEN FUSE NH 000 63A 500V GG-3PCS NH000GG50V63/3

MERSEN FUSE NH 000 63A 500V GG-3PCS NH000GG50V63/3

Mersen NH000GG50V63/3 pack of three DIN NH000 gG fuse-links, each rated 63 A, 500 V AC and 250 V DC, with double indicators and live gripping tags.

SKU: NH000GG50V63/3Alt SKU: NH000GG50V63/3MPN: E213996C
Price
List Price £4.93 ex VAT
Your Price (ex VAT) Save 40%
£2.96 40% OFF
You save £1.97 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2.96
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 3

£2.96

Why Choose the Mersen NH000GG50V63/3 NH Fuse-Link Pack?

The Mersen NH000GG50V63/3 is a convenient pack of three DIN NH gG low voltage fuse-links designed to provide full-range overload and short-circuit protection for cables, conductors and electrical equipment. Each compact NH000 fuse-link is rated at 63 A, making the pack suitable for three-phase installations, replacement stock and industrial maintenance requirements.

Part of the established Mersen NH gG 500 V AC fuse-link range, each fuse incorporates a double blown-fuse indicator and live gripping tags. These features enable qualified electrical professionals to identify an operated fuse quickly and replace it using an appropriate NH fuse-link replacement device.

Each NH000GG50V63 fuse-link is rated for 500 V AC and 250 V DC operation. The gG full-range characteristic provides protection against both sustained overload currents and high prospective short-circuit currents, making this three-pack suitable for switchgear, distribution boards, control panels and OEM electrical equipment.

Key Advantages

  • Convenient pack containing three NH000 gG fuse-links.
  • 63 A rated current per fuse-link.
  • 500 V AC and 250 V DC operating ratings.
  • Provides full-range overload and short-circuit protection.
  • Suitable for coordinated protection of three-phase circuits.
  • Double indicator supports rapid fuse-status identification.
  • Live gripping tags permit handling with the correct NH replacement device.
  • Compact construction for space-conscious switchgear installations.

Key Features

  • Mersen NH gG 500 V AC fuse-link series.
  • Catalogue number: NH000GG50V63/3.
  • Item number: E213996C.
  • Package quantity: Three fuse-links.
  • NH000 fuse size.
  • 63 A rated current per fuse-link.
  • 500 V AC / 250 V DC rated voltage.
  • gG full-range operating characteristic.
  • Double blown-fuse indication.
  • Live gripping tags and ceramic fuse body.

Reliable Protection for Electrical Distribution Systems

gG fuse-links provide full-range protection, allowing them to respond to both overload currents and severe short-circuit faults. Their current-limiting operation helps reduce the thermal and mechanical stresses imposed on cables, switchgear and connected equipment during electrical fault conditions.

The Mersen NH000GG50V63/3 pack supplies three matching fuse-links for use in compatible NH000 fuse bases. This makes it a practical option for three-phase distribution systems, scheduled maintenance and facilities that require readily available replacement fuse-links.

Typical Applications

  • Three-phase electrical distribution systems.
  • Industrial switchgear assemblies.
  • Electrical distribution boards.
  • Cable and conductor protection.
  • Motor control centres.
  • Industrial control panels.
  • OEM machinery and electrical equipment.
  • Commercial and industrial maintenance stock.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Dual indicator
Current 63 A
Voltage 500 V
Device Type Fuse link
Fuse Type NH (DIN)
Fuse Size NH000
Fuse Class gG
Manufacturer Mersen
Series NH gG 500 V AC Fuse-Links
Model NH000GG50V63/3
Item number E213996C
Product type DIN NH gG fuse-link pack
Package quantity 3 fuse-links
Fuse size NH000
Rated current 63 A per fuse-link
Rated AC voltage 500 V AC
Rated DC voltage 250 V DC
Operating characteristic gG
Body width 21 mm per fuse-link
Indicator Double indicator
Gripping tags Live gripping tags
Mounting system NH plug-in fuse system
Body material Ceramic
Compliance RoHS compliant
HS Code 85361050
Country of Manufacture Hungary

Frequently Asked Questions

What is the Mersen NH000GG50V63/3 used for?

This product provides overload and short-circuit protection for cables, conductors and electrical equipment in low voltage distribution systems.

What does the /3 designation mean?

The /3 designation indicates that the product is supplied as a pack of three identical NH000 fuse-links.

What is the rated current of each fuse-link?

Each fuse-link in the pack has a rated current of 63 A.

What voltage ratings do these fuse-links have?

Each fuse-link is rated for operation at up to 500 V AC and 250 V DC.

What does the gG characteristic mean?

The gG characteristic identifies a full-range fuse-link designed to protect cables and general electrical installations against both overload and short-circuit currents.

Trusted by Electrical Professionals Worldwide

Mersen NH fuse-links are widely specified by electrical engineers, panel builders and OEM manufacturers for dependable circuit protection, robust construction and reliable performance in low voltage power distribution systems.