MERSEN FUSE NH 000 50A 500V GG-3PCS NH000GG50V50/3

MERSEN FUSE NH 000 50A 500V GG-3PCS NH000GG50V50/3

Mersen NH000GG50V50/3 DIN NH Size 000 gG fuse link with 50 A rating, 500 V AC and 250 V DC operation, double indicator and live gripping lugs, supplied as a pack of 3 for industrial circuit protection.

SKU: NH000GG50V50/3Alt SKU: NH000GG50V50/3MPN: T212974C
Price
List Price £4.93 ex VAT
Your Price (ex VAT) Save 40%
£2.96 40% OFF
You save £1.97 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2.96
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 3

£2.96

Why Choose the Mersen NH000GG50V50/3 NH Fuse Link?

The Mersen NH000GG50V50/3 is a high-performance DIN NH gG fuse link designed to provide dependable protection against overloads and short circuits in low voltage electrical distribution systems. Manufactured by Mersen, a global leader in electrical protection solutions, this NH fuse is engineered to safeguard switchgear, distribution panels and industrial power installations.

Designed in accordance with IEC standards, the NH000GG50V50/3 features a 50 A current rating, 500 V AC and 250 V DC operation, making it suitable for protecting cables, motors, transformers and general electrical equipment. The live gripping lugs with a double indicator enable safer handling and fast visual identification of fuse operation.

Supplied as a pack of 3, this NH Size 000 fuse link offers reliable circuit protection in demanding industrial and commercial environments while maintaining excellent breaking capacity and long service life.

Key Advantages

  • High-quality DIN NH gG fuse link for industrial circuit protection.
  • 50 A current rating for reliable overload and short circuit protection.
  • 500 V AC / 250 V DC operating voltage.
  • Suitable for protecting cables, motors, transformers and distribution equipment.
  • Double indicator enables quick fuse status identification.
  • Live gripping lugs simplify installation and replacement by qualified personnel.
  • Supplied in a convenient pack of 3.

Key Features

  • Mersen NH fuse-link gG series.
  • NH Size 000.
  • 50 A rated current.
  • 500 V AC / 250 V DC rated voltage.
  • General purpose gG utilisation category.
  • Double indicator with live gripping lugs.
  • Body width approximately 21 mm.
  • Designed to IEC / DIN NH standards.

Reliable Protection for Low Voltage Distribution

NH fuse links are designed to protect electrical circuits from overload and short circuit faults before damage occurs to connected equipment. The Mersen NH000GG50V50/3 delivers fast and dependable fault clearance, helping minimise downtime and improving the safety of industrial electrical installations.

Its robust construction and compliance with international standards make it suitable for use in switchboards, panel building, industrial machinery and commercial power distribution systems where dependable overcurrent protection is essential.

Typical Applications

  • Industrial switchgear.
  • Low voltage power distribution panels.
  • Motor protection circuits.
  • Cable and conductor protection.
  • Transformer protection.
  • Commercial and industrial electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Dual indicator
Current 50 A
Voltage 500 V
Device Type Fuse link
Fuse Type NH (DIN)
Fuse Size NH000
Fuse Class gG
Manufacturer Mersen
Series NH Fuse-links gG 500 VAC
Model NH000GG50V50/3
Product type NH fuse link
Fuse size NH000
Rated current 50 A
Rated voltage AC 500 V AC
Rated voltage DC 250 V DC
Utilisation category gG
AC/DC AC/DC
Body width Approx. 21 mm
Weight Approx. 0.13 kg
Indicator Double indicator
Pack quantity 3
HS Code 85361050
Country of Manufacture Hungary

Frequently Asked Questions

What is the Mersen NH000GG50V50/3 used for?

It provides overload and short circuit protection for low voltage electrical distribution systems, motors, cables and industrial equipment.

What is the current rating of this fuse?

The fuse has a 50 A rated current.

What voltage is the fuse rated for?

The NH000GG50V50/3 is rated for 500 V AC and 250 V DC operation.

What does the gG classification mean?

The gG utilisation category indicates a general purpose full-range fuse suitable for protecting cables and electrical equipment against overloads and short circuits.

What does "/3" mean in the part number?

The "/3" designation indicates the product is supplied as a pack of three fuse links.

Trusted for Industrial Electrical Protection

Mersen NH fuse links are trusted worldwide by panel builders, maintenance engineers and industrial electrical professionals for delivering dependable circuit protection and long-term reliability in demanding power distribution applications.