MERSEN FUSE KIT External CT 150A NH00 3P MZ003SW150

MERSEN FUSE KIT External CT 150A NH00 3P MZ003SW150

3-pole external current transformer with 150/5A ratio and Class 1 accuracy, compatible with NH00 fuse bases for precise industrial current measurement.

SKU: D1024607Alt SKU: MZ003SW150MPN: D1024607
Price
List Price £214.15 ex VAT
Your Price (ex VAT) Save 40%
£128.49 40% OFF
You save £85.66 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £128.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£128.49

Why Choose the Mersen D1024607 MZ003SW150 External Current Transformer Kit?

The Mersen D1024607 is a three-phase external current transformer kit designed for accurate current measurement in conjunction with NH00 MULTIVERT® fuse-switch disconnectors. Also identified by catalogue number MZ003SW150, this kit provides a 150/5 A transformation ratio with Class 1 accuracy, making it suitable for energy monitoring, metering and protection applications in industrial low-voltage power distribution systems.

The kit is installed on the rear of compatible NH00 fuse-switch disconnectors, between the busbar and the MULTIVERT® device. It includes three external current transformers together with distance tubes for level adjustment, allowing a neat installation while maintaining a uniform assembly profile.

Designed specifically for triple-pole measurement, the D1024607 enables accurate monitoring of three-phase electrical systems without requiring integrated current transformers, making it an ideal accessory for industrial switchboards, OEM machinery and commercial electrical distribution equipment.

Key Advantages

  • Provides accurate 150/5 A current measurement.
  • Class 1 accuracy for reliable metering applications.
  • Designed for NH00 MULTIVERT® fuse-switch disconnectors.
  • Supports triple-pole (three-phase) measurement.
  • Rear-mounted installation between busbar and fuse-switch disconnector.
  • Supplied as a complete kit with three current transformers.
  • Includes distance tubes for level adjustment.
  • RoHS compliant construction.

Key Features

  • Mersen External Current Transformer series.
  • External current transformer kit.
  • 150/5 A transformation ratio.
  • Class 1 accuracy.
  • Designed for NH00 fuse-switch disconnectors.
  • Three-pole measurement.
  • Three current transformers included.
  • Distance tubes pre-installed for level adjustment.
  • Rear installation behind MULTIVERT® devices.
  • RoHS compliant.

Accurate Three-Phase Current Monitoring

The Mersen D1024607 enables accurate current measurement for three-phase installations by mounting directly between the busbar and compatible NH00 MULTIVERT® fuse-switch disconnectors. This arrangement provides dependable metering while maintaining a compact switchboard layout.

Supplied as a complete three-piece kit with integrated distance tubes, the MZ003SW150 simplifies installation and helps maintain a consistent installation height across the distribution assembly, making it suitable for professional panel builders and industrial electrical contractors.

Typical Applications

  • Industrial switchboards.
  • Energy monitoring systems.
  • Power metering installations.
  • NH00 MULTIVERT® fuse-switch disconnectors.
  • OEM electrical panels.
  • Motor control centres.
  • Commercial power distribution.
  • Industrial automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current 150 A
Phase Three Phase
Poles 3-pole
Fuse Type NH (DIN)
Fuse Size NH00
Item number D1024607
Catalogue No MZ003SW150
Description Kit External Current transformer 150/5A NH00 3P class 1
EAN/UPC Code 4027597023690
RoHS Compliant Yes
Fuse Size NH00
Design Details current transformer up to 150/5A for triple pole measurement between bus bar and MULTIVERT®, class 1, set = 3 pieces current transformer with distance tubes for level adjustment, 3 pieces installed in the current transformer
Number of Poles 3-Pole
Sell Pack Quantity 1 EA
Sell Pack Weight 0.822 kg
Sell Pack Width 140 mm
Sell Pack Length 120 mm
Sell Pack Height 40 mm
Product group Measurement and monitoring
Product Weight 0.822 kg
HS Code 85363090
Country of Manufacture Hungary

Frequently Asked Questions

What is the Mersen D1024607 used for?

The D1024607 is an external current transformer kit designed to provide accurate three-phase current measurement for NH00 MULTIVERT® fuse-switch disconnectors.

What current ratio does this transformer provide?

The kit has a 150/5 A transformation ratio.

How many current transformers are included?

The kit contains three current transformers for triple-pole measurement together with distance tubes for level adjustment.

What accuracy class is the transformer?

The Mersen D1024607 is manufactured to Class 1 accuracy.

Which fuse-switch disconnectors is it compatible with?

It is designed for installation with NH00 MULTIVERT® fuse-switch disconnectors.

Trusted Current Measurement for Industrial Power Distribution

Mersen external current transformer kits provide reliable and accurate current monitoring for industrial switchboards, helping engineers and panel builders integrate precision metering into modern low-voltage power distribution systems.