MERSEN FUSE IEC Switch 315A 3p R side op. M315E30S

MERSEN FUSE IEC Switch 315A 3p R side op. M315E30S

Mersen M315E30S 315 A three-pole IEC non-fused load break switch featuring a 3+0 configuration and right-hand side operation for industrial power distribution and electrical isolation.

SKU: M315E30SMPN: M315E30S
Price
List Price £459.08 ex VAT
Your Price (ex VAT) Save 25%
£344.31 25% OFF
You save £114.77 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £344.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£344.31

Why Choose the Mersen M315E30S IEC Load Break Switch?

The Mersen M315E30S is a heavy-duty 315 A three-pole IEC non-fused load break switch designed for dependable switching and electrical isolation in low-voltage industrial power distribution systems. Featuring a 3+0 pole configuration with a right-hand side-operated mechanism, it provides reliable load-making and load-breaking performance for demanding switchboard and machinery applications.

Designed for industrial control panels, power distribution assemblies and OEM equipment, the M315E30S combines robust construction with compact dimensions, making it ideal where dependable manual isolation and flexible side-operated switching are required. As a non-fused switch, it enables engineers to select separate overcurrent protection devices that match the electrical installation.

With a rated operational current of 315 A, the M315E30S is suitable for incoming supplies, feeder circuits, motor control centres and industrial process equipment. Its three-pole design simultaneously disconnects all phase conductors, creating a clearly defined isolation point before maintenance or servicing.

Key Advantages

  • Heavy-duty 315 A IEC load break switch.
  • Three-pole 3+0 configuration for three-phase installations.
  • Right-hand side-operated mechanism for flexible enclosure layouts.
  • Reliable load switching and electrical isolation.
  • Non-fused design allows application-specific overcurrent protection.
  • Suitable for industrial switchboards, machinery and power distribution systems.

Key Features

  • Mersen IEC non-fused load break switch.
  • 315 A rated operational current.
  • Three switched power poles.
  • 3+0 pole arrangement.
  • Right-hand side-operated mechanism.
  • Load-making, load-breaking and isolation capability.
  • Heavy-duty industrial construction.
  • Designed for switchboard and panel mounting.

Reliable Side-Operated Isolation for Industrial Systems

The Mersen M315E30S provides a dependable means of switching and isolating three-phase electrical circuits under normal operating conditions. By disconnecting all three phases simultaneously, it creates a safe isolation point for maintenance, inspection and servicing of industrial electrical equipment.

Its right-hand side-operated design is ideal for customised switchboards and machinery where side access to the operating mechanism is preferred. As a non-fused device, the M315E30S should be installed alongside suitable fuse or circuit-breaker protection selected to suit the application.

Typical Applications

  • Industrial switchboards.
  • Power distribution panels.
  • Motor control centres.
  • Incoming and outgoing feeder circuits.
  • Industrial machinery.
  • OEM electrical assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Current 315 A
Phase Three Phase
Poles 3-pole
Device Type Fuse link
Manufacturer Mersen
Model M315E30S
Product type IEC non-fused load break switch
Rated operational current 315 A
Rated operating voltage Up to 1000 V AC (application dependent)
Frequency 50 / 60 Hz
Number of poles 3
Pole configuration 3+0
Operation Right-hand side operated
Fuse protection Non-fused
Mounting type Base mounted
Applicable standard IEC 60947-3

Frequently Asked Questions

What is the Mersen M315E30S used for?

The M315E30S is used to switch and isolate three-phase electrical circuits in industrial switchboards, machinery and low-voltage power distribution systems.

What is the current rating of the M315E30S?

The Mersen M315E30S has a rated operational current of 315 A.

What does the 3+0 pole configuration mean?

The 3+0 configuration indicates that the switch has three switched phase poles with no switched neutral pole.

Is the M315E30S a fused load break switch?

No. The M315E30S is a non-fused IEC load break switch and requires suitable external overcurrent protection.

What is the benefit of the right-hand side-operated design?

The side-operated mechanism provides greater flexibility for switchboard layouts where the operating handle is positioned on the side of the enclosure.

Trusted by Industrial Power Engineers

Mersen IEC load break switches are trusted by switchboard manufacturers, OEMs and industrial electrical engineers for dependable circuit isolation, robust switching performance and long-term reliability in demanding industrial power distribution systems.