MERSEN FUSE H 2409P GEN PURPOSE 442-78/16 45DG240V16P

MERSEN FUSE H 2409P GEN PURPOSE 442-78/16 45DG240V16P

Mersen F1000160 Limitor-G high-voltage DIN general-purpose fuse rated at 24 kV AC and 16 A, with a 40 kA breaking capacity and integrated 80 N striker for transformer protection.

SKU: F1000160Alt SKU: 45DG240V16PMPN: F1000160
Price
List Price £232.99 ex VAT
Your Price (ex VAT) Save 30%
£163.09 30% OFF
You save £69.90 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £163.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£163.09

Why Choose the Mersen F1000160 High-Voltage General-Purpose Fuse?

The Mersen F1000160, catalogue reference 45DG240V16P, is a high-voltage DIN general-purpose fuse-link designed to protect distribution transformers and medium-voltage electrical systems against short-circuit currents and low overcurrents. As part of the Mersen Limitor®-G series, it provides broader protection than a conventional back-up fuse and is suitable for coordinated transformer protection applications.

Rated at 24 kV AC and 16 A, the F1000160 is engineered for use in high-voltage switchgear, controlgear and transformer feeder systems. Its current-limiting operation helps reduce the thermal and mechanical energy passed into protected equipment during electrical fault conditions.

The fuse-link is manufactured with a durable ceramic insulating body, pure silver fuse elements and silver-plated copper terminals. An integrated 80 N striker provides clear operation indication and can activate compatible switchgear mechanisms when the fuse operates.

Key Advantages

  • High-voltage general-purpose fuse for transformer protection.
  • 24 kV AC rated voltage for medium-voltage systems.
  • 16 A rated current.
  • Protects against short-circuit currents and low overcurrents.
  • 40 kA breaking capacity for dependable fault interruption.
  • Integrated 80 N striker for indication and switchgear operation.
  • Current-limiting performance reduces fault energy and equipment stress.
  • Robust ceramic body with high-quality silver conductive components.

Key Features

  • Mersen Limitor®-G general-purpose fuse series.
  • Manufacturer item number F1000160.
  • Catalogue number 45DG240V16P.
  • 24 kV AC IEC rated voltage.
  • 16 A rated current.
  • 40 kA maximum breaking capacity.
  • Total clearing I²t of 14 kA²s at rated voltage.
  • Power dissipation of approximately 21 W at rated current.
  • Integrated striker indication system.
  • Clip-mounted cylindrical DIN construction.
  • Silver-plated copper terminals.
  • Designed in accordance with IEC general-purpose fuse requirements.

Reliable Protection for Medium-Voltage Transformers

The Mersen F1000160 is designed to protect transformers against both severe short-circuit currents and lower-level overcurrents within its specified operating range. Its current-limiting action restricts the peak fault current and let-through energy, helping minimise damage to transformer windings, conductors and switchgear.

As a general-purpose fuse-link, the F1000160 offers a wider protective operating range than a back-up fuse. Correct selection should still consider transformer rating, magnetising inrush current, prospective fault level, ambient temperature and the requirements of the associated switchgear.

Typical Applications

  • Medium-voltage distribution transformer protection.
  • Industrial electrical substations.
  • Air-insulated switchgear systems.
  • Gas-insulated switchgear systems.
  • Ring main units and transformer feeders.
  • Utility power distribution networks.
  • Commercial and infrastructure power systems.
  • Renewable-energy transformer installations.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Striker
Voltage 240 V
Device Type Fuse link
Fuse Type High voltage
Current 16 A
Manufacturer Mersen
Series Limitor®-G
Item number F1000160
Catalogue number 45DG240V16P
Product type High-voltage DIN general-purpose fuse-link
Application Distribution transformer protection
Rated voltage 24 kV AC
Rated current 16 A
Maximum breaking capacity 40 kA
Total clearing I²t at rated voltage 14 kA²s
Power dissipation at rated current 21 W
Current type AC
Fuse operating class General purpose
Striker force 80 N
Indication system Integrated striker
Mounting method Clip mounting
Fuse size Ø78 × 442 mm
Product diameter 78 mm
DIN contact length 442 mm
Overall product length 508 mm
Body material Ceramic
Terminal material Silver-plated copper
Terminal type Cylindrical
Product weight Approximately 4.1 kg
EAN / UPC 3605340453331
Product group High-voltage IEC fuses
Applicable standard IEC 60282-1
RoHS compliant Yes
HS Code 85351000
Country of Manufacture Hungary

Frequently Asked Questions

What is the Mersen F1000160 used for?

The Mersen F1000160 is a high-voltage general-purpose fuse-link used to protect medium-voltage distribution transformers against short-circuit currents and low overcurrents.

What are the voltage and current ratings of the F1000160?

The fuse is rated at 24 kV AC with a nominal current rating of 16 A.

What is the breaking capacity of the Mersen F1000160?

The F1000160 has a maximum AC breaking capacity of 40 kA.

Is the F1000160 a back-up fuse?

No. It is a general-purpose fuse designed to protect against short-circuit currents and lower overcurrents within its specified operating range.

Does the Mersen F1000160 include a striker?

Yes. It includes an integrated 80 N striker for operation indication and activation of compatible switchgear mechanisms.

What are the dimensions of the F1000160?

The fuse has a diameter of approximately 78 mm, a DIN contact length of 442 mm and an overall length of 508 mm.

Trusted High-Voltage Transformer Protection

Mersen Limitor®-G fuse-links are used in medium-voltage transformer and switchgear installations where dependable current limitation, general-purpose protection and robust construction are essential.