MERSEN FUSE H 1209P BCKUP 292-56/10 E1209PIB-D1292/10

MERSEN FUSE H 1209P BCKUP 292-56/10 E1209PIB-D1292/10

Mersen G209306 Limitor-P high-voltage DIN back-up transformer fuse rated at 12 kV AC and 10 A with a standard 80 N striker.

SKU: G209306Alt SKU: 45DB120V10PMPN: G209306
Price
List Price £87.29 ex VAT
Your Price (ex VAT) Save 30%
£61.10 30% OFF
You save £26.19 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £61.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£61.10

Why Choose the Mersen G209306 High-Voltage Fuse?

The Mersen G209306, catalogue number 45DB120V10P, is a high-voltage DIN back-up fuse-link engineered to provide dependable protection for medium-voltage transformers against damaging short-circuit currents. As part of the proven Mersen Limitor®-P range, it delivers reliable current-limiting performance for high-voltage switchgear, transformer feeders and electrical distribution systems.

Rated at 12 kV AC and 10 A, the G209306 rapidly interrupts high fault currents, helping to minimise thermal and mechanical stress on transformers, busbars, cables and associated switchgear. Its robust construction ensures long service life in demanding industrial and utility environments.

Manufactured with a durable ceramic body, pure silver fuse elements and silver-coated copper end caps, the fuse incorporates a standard 80 N striker for operation of compatible switchgear mechanisms or fuse indication. The DIN-format fuse measures approximately 56 mm in diameter and 292 mm in length.

Key Advantages

  • Purpose-designed high-voltage back-up fuse for transformer protection.
  • 12 kV AC rated voltage for medium-voltage installations.
  • 10 A rated current.
  • 63 kA breaking capacity for dependable fault interruption.
  • Current-limiting operation helps minimise equipment damage.
  • Integrated 80 N striker for switchgear tripping or indication.
  • Manufactured using premium ceramic, silver and copper materials.

Key Features

  • Mersen Limitor®-P back-up fuse series.
  • DIN high-voltage transformer fuse-link.
  • 12 kV AC IEC rated voltage.
  • 10 A rated current.
  • 63 kA maximum breaking capacity.
  • 42 A minimum breaking current.
  • 3 kA²s clearing I²t.
  • 16 W power dissipation at rated current.
  • 56 mm fuse diameter.
  • 292 mm fuse length.
  • 80 N standard striker.
  • Pure silver fuse elements with ceramic insulating body.

Reliable Protection for Medium-Voltage Transformers

The Mersen G209306 is a back-up current-limiting fuse developed specifically for transformer protection. It rapidly interrupts high fault currents before they reach their maximum value, reducing the energy released into the protected installation and helping extend the service life of transformers and associated switchgear.

Its integrated striker allows compatible switchgear to respond automatically when the fuse operates, improving operational safety while reducing downtime following electrical faults.

Typical Applications

  • Medium-voltage transformer protection.
  • High-voltage switchgear.
  • Transformer feeder panels.
  • Fuse-switch combination units.
  • Industrial electrical distribution systems.
  • Utility substations.
  • Commercial infrastructure power networks.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Fuse link
Fuse Type High voltage
Current 10 A
Voltage 12000 V
Manufacturer Mersen
Series Limitor®-P
Item number G209306
Catalogue number 45DB120V10P
Product type High-voltage DIN back-up fuse-link
Primary application Medium-voltage transformer protection
Rated voltage 12 kV AC
Rated current 10 A
Current type AC
Maximum breaking capacity 63 kA
Minimum breaking current 42 A
Clearing I²t 3 kA²s
Power dissipation 16 W
Fuse diameter 56 mm
Fuse length 292 mm
Striker force 80 N
Fuse element material Pure silver
End-cap material Silver-coated copper
Body material Ceramic
Applicable standard IEC 60282-1
Weight Approximately 1.7 kg
EAN / UPC 3605340218046
RoHS compliant Yes
HS Code 85351000

Frequently Asked Questions

What is the Mersen G209306 used for?

The G209306 is a high-voltage DIN back-up fuse designed to protect medium-voltage transformers against high short-circuit currents.

What are the voltage and current ratings?

This fuse is rated at 12 kV AC with a 10 A current rating.

What is the catalogue number?

The corresponding Mersen catalogue number is 45DB120V10P.

Does the fuse include a striker?

Yes. The G209306 incorporates a standard 80 N striker for operation of compatible switchgear or indication mechanisms.

What are the dimensions of the G209306?

The fuse measures approximately 56 mm in diameter and 292 mm in length.

Trusted High-Voltage Protection from Mersen

Mersen Limitor®-P fuse-links are trusted by utilities, OEMs and industrial engineers for dependable transformer protection, high breaking capacity and reliable performance in medium-voltage electrical distribution systems.