MERSEN FUSE BTSDC42V63M100 B1C BTSDC42V63M100

MERSEN FUSE BTSDC42V63M100 B1C BTSDC42V63M100

British Standard fuse-link IEC BS88 gM Type B1 415VAC 240VDC 63M100A BTSDL Central Bolted Tag designed for motor and mixed load protection with high breaking capacity.

SKU: BTSDC42V63M100Alt SKU: BTSDC42V63M100MPN: L1019209
Price
List Price £40.97 ex VAT
Your Price (ex VAT) Save 60%
£16.39 60% OFF
You save £24.58 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £16.39
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 10

£16.39

Why Choose the Mersen BTSDC42V63M100 BS88 gM Motor Fuse Link?

The Mersen BTSDC42V63M100 is a high-performance BS88 gM motor fuse link designed to provide dependable short-circuit protection for electric motors and associated industrial equipment. Manufactured by Mersen, it is engineered to tolerate the temporary inrush currents produced during motor starting while rapidly interrupting dangerous fault currents.

The BTSDC42V63M100 is suitable for coordinated motor protection systems incorporating contactors, motor starters and correctly selected overload relays. Its current-limiting operation helps reduce the peak current and fault energy passed to cables, switchgear and downstream components during a short circuit.

Featuring a 63 A continuous current rating, a 100 A motor circuit rating and an operating voltage of up to 415 V AC, this fuse link is suitable for demanding motor control and industrial automation applications. Its robust tagged construction supports secure installation in compatible BS88 fuse holders, fused switches and switch-disconnectors.

Key Advantages

  • Purpose-designed gM fuse link for industrial motor protection.
  • 63 A continuous current rating with a 100 A motor circuit designation.
  • 415 V AC rated voltage for low-voltage industrial systems.
  • Tolerates normal motor starting currents without unnecessary operation.
  • Current-limiting performance helps reduce damaging fault energy.
  • Suitable for coordinated use with motor overload protection devices.

Key Features

  • Mersen industrial motor fuse-link range.
  • BS88 gM fuse utilisation category.
  • 63M100 motor fuse rating.
  • 415 V AC rated voltage.
  • Designed primarily for motor circuit short-circuit protection.
  • Allows temporary motor starting and acceleration currents.
  • Effective current limitation during high-level electrical faults.
  • Suitable for industrial fuse holders and switch-disconnectors.

Reliable Short-Circuit Protection for Industrial Motors

Electric motors can draw several times their normal operating current while starting. The Mersen BTSDC42V63M100 is designed to withstand these temporary inrush currents while providing rapid interruption when a genuine short circuit occurs. This helps protect motor cables, contactors, starters and associated switchgear from damaging fault energy.

As a gM fuse link, the BTSDC42V63M100 is primarily intended to provide short-circuit protection rather than complete overload protection. It should therefore be coordinated with a suitable overload relay or motor protection device to provide comprehensive protection for the motor circuit.

Typical Applications

  • Industrial motor starters.
  • Motor control centres.
  • Pumps, fans and compressor systems.
  • Conveyors and material handling equipment.
  • Manufacturing and processing machinery.
  • Industrial switchboards and automation panels.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Class gM
Voltage 415 V
Item number L1019209
Catalogue No BTSDC42V63M100
Description British Standard fuse-link IEC BS88 gM Type B1 415VAC 240VDC 63M100A BTSDL Central Bolted Tag
EAN/UPC Code 3605340515985
Rated voltage AC IEC 415 V
Rated voltage DC IEC 240 V
In M Ich 63M100 A
RoHS Compliant Yes
AC or DC AC/DC
Speed/Characteristic gM
Fuse Size B1
Mounting Bolted
Clearing I2t At Rated Voltage 65000 A²s
Melting I2t 14000 A²s
AC Max I.R./Breaking Capacity I1: 80 kA
Max. Rated Breaking Capacity DC 40 kA
Connection/Terminal Material Tin-Plated Copper
Connection/Terminal Type Central Bolted Tag
Product Diameter 21 mm
Product Length 127 mm
Sell Pack Quantity 10 EA
Sell Pack Weight 0.86 kg
Sell Pack Width 135 mm
Sell Pack Length 143 mm
Sell Pack Height 55 mm
Product group Low Voltage IEC Fuses
Body/Insulating Material Ceramic
Product Weight 0.086 kg
Power Dissipation at Rated Current Value 4.7 W

Frequently Asked Questions

What is the Mersen BTSDC42V63M100 used for?

The BTSDC42V63M100 is used to provide short-circuit protection for electric motors, motor starters and associated industrial electrical equipment.

What does the 63M100 rating mean?

The 63M100 designation identifies a motor-rated fuse link with a 63 A continuous current rating and a 100 A motor circuit rating.

What voltage is the BTSDC42V63M100 rated for?

The fuse link is designed for electrical systems operating at up to 415 V AC.

Does this fuse provide motor overload protection?

A gM fuse primarily provides short-circuit protection and should normally be coordinated with a correctly selected overload relay or motor protection device.

Where is this fuse typically installed?

The BTSDC42V63M100 is typically installed in a compatible BS88 fuse holder, motor starter, fused switch-disconnector or motor control centre.

Trusted for Industrial Motor Protection

Mersen motor fuse links are used by electrical engineers, panel builders and industrial maintenance teams to provide dependable fault protection and effective coordination within demanding motor control systems.