MERSEN FUSE BJU42V560SD BJU42V560SD

MERSEN FUSE BJU42V560SD BJU42V560SD

High-performance BS88 gU Type 130×74 fuse-link rated at 560A and 415VAC, suitable for industrial circuit protection with 80kA breaking capacity and ceramic body.

SKU: G1003956Alt SKU: BJU42V560SDMPN: G1003956
Price
List Price £98.43 ex VAT
Your Price (ex VAT)
£98.43
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £98.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£98.43

Why Choose the Mersen G1003956 BJU42V560SD BS88 Feeder Pillar Fuse?

The Mersen G1003956 (BJU42V560SD) is a high-performance BS88 gU feeder pillar fuse link designed to provide dependable overload and short-circuit protection for street lighting networks and low voltage electrical distribution systems. Manufactured by Mersen, this industrial fuse delivers excellent current limiting performance for demanding utility, infrastructure and industrial applications.

Designed in accordance with BS88-5 and IEC 60269-2, the BJU42V560SD is engineered for feeder pillar installations where rapid fault isolation, reliable discrimination and high fault interruption capability are essential. Its ceramic construction and current limiting characteristics help minimise damage to downstream equipment during fault conditions.

With a 560 A rated current, 415 V AC operating voltage and an impressive 80 kA breaking capacity, the G1003956 is ideally suited to public lighting systems, utility feeder pillars and industrial low voltage power distribution networks.

Key Advantages

  • High-performance BS88 feeder pillar fuse link.
  • 560 A rated current for heavy-duty distribution circuits.
  • 415 V AC operating voltage.
  • 80 kA AC breaking capacity for dependable fault interruption.
  • Excellent current limiting characteristics.
  • Manufactured to BS88-5 and IEC 60269-2 standards.

Key Features

  • Mersen BJU Series.
  • Catalogue number: BJU42V560SD.
  • 560 A rated current.
  • 415 V AC rated voltage.
  • gU utilisation category.
  • 80 kA AC breaking capacity.
  • Ceramic fuse body for reliable long-term performance.
  • Designed for feeder pillar and low voltage power distribution applications.

Reliable Protection for Heavy-Duty Distribution Networks

The Mersen G1003956 rapidly interrupts overload and fault currents to protect feeder pillars, switchgear and distribution cables against electrical damage. Its high current limiting performance helps reduce thermal and mechanical stresses during fault conditions, improving network reliability and reducing maintenance costs.

Specified by utility companies, electrical contractors and infrastructure engineers, the BJU series delivers dependable long-term protection for public lighting installations and industrial low voltage electrical distribution systems operating under demanding conditions.

Typical Applications

  • Street lighting feeder pillars.
  • Public infrastructure electrical networks.
  • Low voltage power distribution systems.
  • Utility distribution equipment.
  • Industrial electrical installations.
  • Commercial distribution panels.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Class gG
Voltage 415 V
Item number G1003956
Catalogue No BJU42V560SD
Description British Standard fuse-link IEC BS88 gU Type 130x74 415VAC 560A
EAN/UPC Code 3605340478426
Rated voltage AC IEC 415 V
Ampere Rating 560 A
RoHS Compliant Yes
AC or DC AC
Speed/Characteristic gG
Fuse Size 130x74
Mounting Clip
Clearing I2t At Rated Voltage 2910000 A²s
Melting I2t 485000 A²s
AC Max I.R./Breaking Capacity I1: 80 kA
Connection/Terminal Material Copper
Connection/Terminal Type Blade
Product Diameter 74.3 mm
Product Length 130.5 mm
Product Height 41 mm
Sell Pack Quantity 1 EA
Sell Pack Weight 0.706 kg
Sell Pack Width 155 mm
Sell Pack Length 80 mm
Sell Pack Height 80 mm
Product group Low Voltage IEC Fuses
Body/Insulating Material Ceramic
Product Weight 0.706 kg
Power Dissipation at Rated Current Value 35 W
HS Code 85361090
Country of Manufacture India

Frequently Asked Questions

What is the Mersen G1003956 used for?

The G1003956 provides overload and short-circuit protection for feeder pillars, street lighting systems and low voltage electrical distribution networks.

What is the current rating of this fuse?

The Mersen G1003956 has a 560 A rated current.

What voltage is the G1003956 designed for?

This fuse is designed for electrical systems operating up to 415 V AC.

What is the breaking capacity?

The fuse provides a rated breaking capacity of 80 kA AC, enabling safe interruption of high prospective fault currents.

Where is this fuse typically installed?

It is commonly installed in feeder pillars, utility distribution equipment, street lighting networks and industrial low voltage distribution systems.

Trusted by Utility and Electrical Professionals

Mersen BS88 feeder pillar fuse links are trusted worldwide by utility companies, electrical contractors and infrastructure engineers for delivering reliable circuit protection, excellent current limitation and dependable long-term performance.