MERSEN FUSE 500V CP 14X51 GG 2A P FR14GG50V2P

MERSEN FUSE 500V CP 14X51 GG 2A P FR14GG50V2P

Mersen FR14GG50V2P 2 A 500 V AC gG cylindrical fuse link with striker, designed to provide full-range overload and short-circuit protection in electrical distribution circuits.

SKU: FR14GG50V2PAlt SKU: FR14GG50V2PMPN: J211033
Price
List Price £5.79 ex VAT
Your Price (ex VAT) Save 40%
£3.47 40% OFF
You save £2.32 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3.47
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 10

£3.47

Why Choose the Mersen FR14GG50V2P Cylindrical Fuse Link?

The Mersen FR14GG50V2P is a high-quality 14 × 51 mm gG cylindrical fuse link designed to protect cables, electrical distribution circuits and industrial equipment against overload and short-circuit currents. Rated at 2 A and 500 V AC, it provides dependable full-range protection for low-current circuits in industrial and commercial electrical installations.

As a gG general-purpose fuse link, the FR14GG50V2P operates across its complete current range, protecting connected equipment against sustained overloads as well as high prospective short-circuit currents. Its current-limiting performance helps reduce the thermal and electrodynamic stresses placed on cables, switchgear and downstream components during fault conditions.

This model includes an integrated striker mechanism that can provide clear fuse operation indication or activate an auxiliary contact when installed in a compatible fuse holder. Its standard 14 × 51 mm format makes it suitable for compact control panels, distribution assemblies and industrial machinery.

Key Advantages

  • Provides full-range overload and short-circuit protection.
  • 2 A rated current for low-current electrical circuits.
  • 500 V AC rated voltage for industrial installations.
  • gG utilisation category for general-purpose circuit protection.
  • Integrated striker for fuse operation signalling.
  • Compact 14 × 51 mm cylindrical format for panel installation.

Key Features

  • Mersen FR14 gG cylindrical fuse-link series.
  • 2 A rated current.
  • 500 V AC IEC rated voltage.
  • gG full-range fuse characteristic.
  • Protection against overload and short-circuit currents.
  • Integrated striker for local or remote fuse operation indication.
  • High current-limiting performance during fault conditions.
  • Standard 14 × 51 mm cylindrical dimensions.
  • Suitable for compatible fuse holders and mounting clips.
  • Manufactured in accordance with IEC 60269 requirements.

Reliable Protection for Electrical Distribution Circuits

The Mersen FR14GG50V2P is designed to protect conductors and electrical equipment from the damaging effects of abnormal current. Its gG operating characteristic responds to both prolonged overloads and severe short-circuit faults, providing comprehensive protection across the fuse link’s operating range.

During a high-current fault, the fuse rapidly limits and interrupts the current, helping reduce thermal damage and mechanical stress within the electrical installation. The integrated striker also supports faster fault identification and can be used with a compatible auxiliary contact for remote fuse status monitoring.

Typical Applications

  • Industrial electrical distribution systems.
  • Cable and conductor protection.
  • Control panels and switchgear assemblies.
  • Low-voltage distribution boards.
  • Industrial machinery and production equipment.
  • OEM panels and automation systems.
  • Commercial electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Striker
Current 2 A
Voltage 500 V
Device Type Fuse link
Fuse Type Cylindrical
Fuse Size 14x51 mm
Fuse Class gG
Manufacturer Mersen
Series FR14 gG Cylindrical Fuse Links
Model FR14GG50V2P
Manufacturer item number J211033
Product type Cylindrical general-purpose fuse link
Fuse utilisation category gG
Rated current 2 A
Rated voltage 500 V AC
Fuse size 14 × 51 mm
Protection range Full-range overload and short-circuit protection
Indication system Striker
Connection type Cylindrical ferrule
Mounting method Compatible fuse holder or mounting clip
Applicable standards IEC 60269-1 and IEC 60269-2
Application class Electrical distribution circuit protection
HS Code 85361010
Country of Manufacture Tunisia

Frequently Asked Questions

What is the Mersen FR14GG50V2P used for?

The FR14GG50V2P is used to protect cables, electrical distribution circuits and industrial equipment against overload and short-circuit currents.

What are the electrical ratings of this fuse?

The fuse has a rated current of 2 A and a rated voltage of 500 V AC.

What does the gG classification mean?

The gG classification identifies a general-purpose, full-range fuse link that provides protection against both overload currents and short-circuit faults.

What does the integrated striker do?

The striker provides an indication when the fuse has operated and can activate an auxiliary contact when used with a compatible fuse holder.

What size fuse holder is required?

The FR14GG50V2P requires a compatible fuse holder designed for 14 × 51 mm cylindrical fuse links.

Trusted Industrial Circuit Protection from Mersen

Mersen cylindrical fuse links are widely specified by electrical engineers, panel builders and equipment manufacturers for dependable protection of cables, distribution circuits and industrial electrical installations.