MERSEN FUSE 369P CPASJB 45/67.292 200 369PCPASJB45/67.292200

MERSEN FUSE 369P CPASJB 45/67.292 200 369PCPASJB45/67.292200

Mersen R075524 Limitor aSJB/D high voltage motor protection back-up fuse-link rated at 3.6 kV AC and 200 A, with a 60 kA breaking capacity and integrated 20 N striker.

SKU: R075524MPN: R075524
Price
List Price £852.28 ex VAT
Your Price (ex VAT) Save 30%
£596.60 30% OFF
You save £255.68 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £596.60
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 3

£596.60

Why Choose the Mersen R075524 High Voltage Motor Protection Fuse?

The Mersen R075524 is a dependable high voltage motor protection back-up fuse-link designed to protect medium voltage motors, switchgear and associated electrical equipment against damaging short-circuit currents. As part of the established Mersen Limitor® aSJB/D series, it is engineered specifically for motor circuits that experience repeated peak currents during starting.

The R075524 uses silver-plated copper fuse elements, silver-plated brass terminals and a durable melamine fibreglass insulating body. This robust construction provides reliable electrical performance, effective current limitation and dependable operation within demanding industrial and utility installations.

With a rated voltage of 3.6 kV AC, a rated current of 200 A and a maximum breaking capacity of 60 kA, the R075524 provides reliable protection for compatible medium voltage motor circuits. Its integrated 20 N striker supports fault indication and operation of suitable switching equipment following fuse operation.

Key Advantages

  • Designed specifically for medium voltage motor protection.
  • 3.6 kV AC rated voltage for industrial motor circuits.
  • 200 A rated current for compatible high voltage motors.
  • 60 kA breaking capacity for dependable fault interruption.
  • Designed to withstand repeated peak currents during motor starting.
  • Integrated 20 N striker for fault indication and switchgear operation.
  • Current-limiting performance helps reduce damaging fault energy.
  • Robust melamine fibreglass construction supports dependable service life.

Key Features

  • Mersen Limitor® aSJB/D high voltage motor fuse-link.
  • Catalogue number: 45ASB36V200P-2.
  • Rated voltage: 3.6 kV AC.
  • Rated current: 200 A.
  • Maximum breaking capacity: 60 kA.
  • Fuse body size: 67 mm diameter × 292 mm length.
  • Overall product length: 358 mm.
  • Integrated 20 N striker mechanism.
  • Clip mounting with cylindrical terminals.
  • Motor fuse design in accordance with IEC 60282-1 and IEC 60644.

Reliable Protection for Medium Voltage Motors

Motor protection back-up fuse-links are designed to interrupt severe short-circuit currents rapidly while tolerating the repeated inrush currents generated during motor starting. Their current-limiting characteristics reduce the peak current and fault energy imposed on motors, cables, contactors and associated switchgear.

The Mersen R075524 combines a high breaking capacity with motor-specific operating characteristics and an integrated striker. When the fuse-link operates, the striker can provide fault indication or activate compatible switching equipment, supporting coordinated isolation and safer maintenance.

Typical Applications

  • Medium voltage electric motors.
  • Industrial motor control centres.
  • Pump and compressor installations.
  • Mining and quarrying equipment.
  • Water and wastewater treatment plants.
  • Power generation facilities.
  • High voltage motor starters.
  • OEM medium voltage switchgear.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Indication Striker
Device Type Fuse link
Fuse Type High voltage
Current 200 A
Voltage 3600 V
Manufacturer Mersen
Series Limitor® aSJB/D
Model R075524
Catalogue number 45ASB36V200P-2
Product type High voltage motor protection back-up fuse-link
Primary application Medium voltage motor protection
Rated voltage 3.6 kV AC IEC
Rated current 200 A
Current type AC
Maximum breaking capacity 60 kA
Minimum interrupting rating 1,250 A
Clearing I²t at rated voltage 370 kA²s
Power dissipation 33 W at 0.7 × rated current
Motor factor K 0.51
Fuse body diameter 67 mm
Fuse body length 292 mm
Overall product length 358 mm
Mounting type Clip mounting
Indication system Striker
Striker force 20 N
Fuse-element material Silver-plated copper
Terminal material Silver-plated brass
Terminal type Cylindrical
Body material Melamine fibreglass
Product weight Approx. 2.7 kg
RoHS compliant Yes
EAN 3605340009736
Applicable standards IEC 60282-1 and IEC 60644

Frequently Asked Questions

What is the Mersen R075524 used for?

The Mersen R075524 is a high voltage back-up fuse-link designed to protect medium voltage motors and associated switchgear against damaging short-circuit currents.

What are the voltage and current ratings?

The fuse-link has a rated voltage of 3.6 kV AC and a rated current of 200 A.

What is the breaking capacity of the R075524?

The Mersen R075524 has a maximum AC breaking capacity of 60 kA.

What size is the R075524 fuse-link?

The fuse body measures 67 mm in diameter and 292 mm in length, with an overall product length of 358 mm.

Does this fuse include a striker?

Yes. It incorporates a 20 N striker for fault indication and operation of compatible switchgear following fuse operation.

Can the R075524 withstand motor starting currents?

Yes. The Limitor® aSJB/D fuse-link is specifically designed to support repeated peak currents generated during medium voltage motor starting.