MERSEN FUSE 3200 CP GLB 10.180 0,16 10GB32V0,16

MERSEN FUSE 3200 CP GLB 10.180 0,16 10GB32V0,16

Mersen E081838 3.2 kV AC, 0.16 A gLB medium-voltage current-limiting fuse link with a compact 10 x 180 mm cylindrical body for specialist electrical protection applications.

SKU: E081838MPN: E081838
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Mersen E081838 Medium-Voltage Fuse Link?

The Mersen E081838 is a compact medium-voltage current-limiting fuse link designed to protect lighting circuits, voltage transformers and other specialist electrical equipment against damaging fault currents. Identified by the manufacturer designation 3200 CP gLB 10.180/0.16, this fuse has a rated current of 0.16 A and a rated voltage of 3.2 kV AC.

As part of Mersen's European medium-voltage fuse range, the E081838 provides rapid interruption and effective current limitation when a qualifying short circuit occurs. Limiting the peak fault current and let-through energy helps reduce thermal and mechanical stress on connected equipment, conductors and switchgear.

The fuse features a compact 10 × 180 mm cylindrical format and is supplied without a trip indicator. The Mersen E081838 is now listed as a discontinued or end-of-life product, so availability may be limited. Please call 01706 242050 for stock information or assistance identifying a suitable replacement.

Key Advantages

  • Compact 3.2 kV medium-voltage fuse link.
  • 0.16 A rated current for specialist low-current applications.
  • Current-limiting operation helps reduce peak fault current.
  • gLB operating class for appropriate medium-voltage lighting applications.
  • Compact 10 × 180 mm cylindrical construction.
  • Proven Mersen circuit protection technology.

Key Features

  • Mersen European medium-voltage fuse range.
  • Manufacturer reference E081838.
  • Designation 3200 CP gLB 10.180/0.16.
  • 3.2 kV AC rated voltage.
  • 0.16 A rated current.
  • gLB fuse utilisation category.
  • Current-limiting short-circuit protection.
  • Fuse link supplied without a trip indicator.

Reliable Protection for Specialist Medium-Voltage Circuits

Medium-voltage current-limiting fuses interrupt high fault currents before they reach their prospective peak. This helps minimise the let-through energy delivered to connected components and reduces the risk of severe thermal or mechanical damage within the electrical installation.

The Mersen E081838 must be selected and installed as part of a correctly engineered protection system. Suitability depends on the system voltage, normal operating current, prospective fault level, fuse-holder dimensions and the protection requirements of the connected equipment.

Typical Applications

  • Medium-voltage lighting circuits.
  • Voltage transformer protection.
  • Auxiliary medium-voltage circuits.
  • Industrial switchgear and controlgear.
  • Specialist power distribution equipment.
  • Maintenance of legacy electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Fuse link
Fuse Type Cylindrical
Current 0.16 A
Voltage 3200 V
Manufacturer Mersen
Model E081838
Manufacturer designation 3200 CP gLB 10.180/0.16
Product type Medium-voltage cylindrical fuse link
Rated voltage 3.2 kV AC
Rated current 0.16 A
Fuse class gLB
Fuse dimensions 10 × 180 mm
Operating principle Current limiting
Trip indicator No
Mounting type Compatible cylindrical fuse holder
Approximate weight 0.03 kg
GTIN / EAN 3605340049350
Product status Discontinued / end of life

Frequently Asked Questions

What is the Mersen E081838 used for?

The Mersen E081838 is designed to provide current-limiting short-circuit protection for compatible medium-voltage lighting, transformer and auxiliary electrical circuits.

What are the electrical ratings of the E081838?

The fuse has a rated voltage of 3.2 kV AC and a rated current of 0.16 A.

What are the dimensions of this fuse link?

The Mersen E081838 has a compact cylindrical body measuring approximately 10 × 180 mm.

Does the E081838 have a trip indicator?

No. This version is supplied without a mechanical trip indicator or striker.

Is the Mersen E081838 still available?

The E081838 is listed as a discontinued or end-of-life product, so remaining availability may be limited. Call 01706 242050 for current stock information or help identifying a suitable alternative.

Trusted by Power Distribution Professionals Worldwide

Mersen medium-voltage fuse links are trusted by electrical engineers, switchgear manufacturers and maintenance professionals to provide reliable fault-current limitation and protection for specialist power distribution equipment.