MERSEN FUSE 100M160A4C BTCP42V100M160

MERSEN FUSE 100M160A4C BTCP42V100M160

The BS88 gM Type A4 fuse-link delivers reliable protection for motor and general applications, rated for 415VAC and 240VDC up to 160A with BTCP offset tag terminals for secure connections.

SKU: BTCP42V100M160Alt SKU: BTCP42V100M160MPN: B226298
Price
List Price £31.99 ex VAT
Your Price (ex VAT) Save 60%
£12.80 60% OFF
You save £19.19 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12.80
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 10

£12.80

Why Choose the Mersen BTCP42V100M160 British Standard Fuse-Link?

The Mersen BTCP42V100M160 is a robust British Standard gM fuse-link designed to provide dependable short-circuit protection for industrial motors and motor control circuits. Its motor-rated operating characteristic allows normal starting currents to pass while rapidly interrupting potentially damaging fault currents.

As part of the established Mersen BTCP offset tag fuse-link range, the BTCP42V100M160 is suitable for use in motor starters, switchgear, control panels and motor control centres. Its current-limiting performance helps reduce thermal and mechanical stress on cables, contactors and other downstream electrical equipment during a short circuit.

Featuring a 100M160 motor circuit rating and a nominal voltage rating of 415 V AC, this fuse-link is intended for demanding industrial installations. Its British Standard offset tag configuration enables secure installation in compatible fuse holders, fused switches and switch-disconnector assemblies.

Key Advantages

  • British Standard gM fuse-link designed for motor circuit protection.
  • 100M160 motor circuit rating for demanding industrial applications.
  • 415 V AC voltage rating suitable for common industrial power systems.
  • Accommodates normal motor starting currents without unnecessary operation.
  • Current-limiting performance helps minimise damage caused by short circuits.
  • Offset tag design provides secure installation in compatible fuse equipment.

Key Features

  • Mersen BTCP British Standard fuse-link series.
  • 100M160 gM motor circuit rating.
  • 415 V AC rated voltage.
  • gM utilisation category for motor circuit protection.
  • High fault-current interruption capability.
  • Effective current limitation during short-circuit conditions.
  • Robust industrial offset tag construction.
  • Compatible with suitable British Standard fuse holders and switchgear.

Reliable Protection for Industrial Motor Circuits

Industrial motors can draw several times their normal operating current during start-up. The Mersen BTCP42V100M160 is engineered to withstand these temporary starting currents while providing fast and effective interruption when a serious short circuit occurs.

As a gM fuse-link, the BTCP42V100M160 is primarily intended to provide short-circuit protection. It should normally be coordinated with a suitable overload relay or motor protection device to provide comprehensive protection against both overload and fault-current conditions.

Typical Applications

  • Industrial motor starters.
  • Motor control centres.
  • Pumps, compressors and ventilation equipment.
  • Conveyors and material handling systems.
  • Manufacturing and processing machinery.
  • Industrial switchgear and control panels.

Technical Specifications

Tick the specs you need, then view products that match.

Fuse Class gM
Voltage 415 V
Item number B226298
Catalogue No BTCP42V100M160
Description British Standard fuse-link IEC BS88 gM Type A4 415VAC 240VDC 100M160A BTCP Offset Tag
EAN/UPC Code 3605340519952
Rated voltage AC IEC 415 V
Rated voltage DC IEC 240 V
In M Ich 100M160 A
RoHS Compliant Yes
AC or DC AC/DC
Speed/Characteristic gM
Fuse Size A4
Mounting Bolted
Clearing I2t At Rated Voltage 168000 A²s
Melting I2t 60000 A²s
AC Max I.R./Breaking Capacity I1: 80 kA
Max. Rated Breaking Capacity DC 40 kA
Connection/Terminal Material Tin-Plated Copper
Connection/Terminal Type Offset Tag
Product Diameter 26.9 mm
Product Width 28.5 mm
Product Length 111 mm
Sell Pack Quantity 10 EA
Sell Pack Weight 1.1 kg
Sell Pack Width 120 mm
Sell Pack Length 230 mm
Sell Pack Height 40 mm
Product group Low Voltage IEC Fuses
Body/Insulating Material Ceramic
Product Weight 0.11 kg
Power Dissipation at Rated Current Value 8.8 W
HS Code 85361090
Country of Manufacture India

Frequently Asked Questions

What is the Mersen BTCP42V100M160 used for?

It is a British Standard gM fuse-link designed to provide short-circuit protection for industrial motors, motor starters and associated electrical equipment.

What does the 100M160 rating mean?

The 100M160 designation identifies the fuse-link's motor circuit rating and its ability to accommodate the temporary high current produced when an industrial motor starts.

What voltage is the BTCP42V100M160 rated for?

The fuse-link has a nominal voltage rating of 415 V AC.

Does this fuse-link provide overload protection?

As a gM fuse-link, it is primarily intended for short-circuit protection and should normally be combined with a suitable overload relay or motor protection device.

Where is this fuse-link typically installed?

It is commonly installed in compatible British Standard fuse holders within motor starters, motor control centres, industrial switchgear and electrical control panels.

Trusted for Industrial Motor Protection

Mersen British Standard motor fuse-links are widely specified by electrical engineers, panel builders and industrial maintenance teams for reliable fault interruption, effective current limitation and dependable operation in demanding motor control systems.