KSF340TPN Fireman switch

KSF340TPN Fireman switch

ABB 2CMA142438R1000 KSF340TPN three-pole 40 A fireman switch with an IP65 enclosure, padlockable emergency handle and a maximum operational voltage of 690 V AC.

SKU: 2CMA142438R1000Alt SKU: KSF340TPNMPN: 2CMA142438R1000
Price
List Price £166.55 ex VAT
Your Price (ex VAT) Save 35%
£108.26 35% OFF
You save £58.29 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £108.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£108.26

Why Choose the ABB KSF340TPN Fireman Switch?

The ABB 2CMA142438R1000, also known as the KSF340TPN, is a robust 40 A three-pole fireman switch designed to provide rapid and dependable electrical isolation during a fire or emergency. It is particularly suitable for disconnecting neon signs, illuminated advertising, exterior lighting and other electrical equipment that could present a hazard to emergency personnel.

The fireman switch features a highly visible red enclosure and an operating handle designed for use with a fireman’s hook stick. Its rigid metal construction and UV-protected finish provide reliable performance in demanding commercial and industrial environments, while the IP65 enclosure protection makes it suitable for both indoor and outdoor installation.

With a rated switching current of 40 A and an operational voltage of up to 690 V AC, the ABB KSF340TPN provides secure isolation for three-phase electrical systems. The switch also includes a fixed neutral terminal and protective earth terminal, making it suitable for five-wire installations where only the three phase conductors require switching.

Key Advantages

  • Purpose-designed fireman switch for emergency electrical isolation.
  • 40 A switching current for commercial and industrial circuits.
  • Supports operational voltages up to 690 V AC.
  • Durable IP65-rated enclosure for indoor and outdoor installation.
  • Highly visible red finish helps emergency personnel locate the switch quickly.
  • Operating handle is suitable for activation with a fireman’s hook stick.
  • Padlockable handle helps prevent unauthorised operation.
  • Interlocked cover improves safety during installation and maintenance.

Key Features

  • ABB KSF series fireman switch.
  • Three switched poles for three-phase electrical systems.
  • 40 A rated switching current.
  • 690 V AC maximum operational voltage.
  • Suitable for switching loads up to approximately 15 kW, depending on the application voltage and utilisation category.
  • IP65 enclosure protection against dust and low-pressure water jets.
  • Rigid metal enclosure with a UV-protected red finish.
  • Fixed neutral and protective earth terminals.
  • Threaded cable entries at the top and bottom.
  • Padlockable emergency operating handle.
  • Cover interlock for enhanced operational safety.
  • Designed in accordance with IEC 60947-3.

Reliable Emergency Electrical Isolation

Fireman switches are installed in accessible exterior or entrance locations so emergency personnel can quickly disconnect potentially hazardous electrical equipment during a fire. The ABB KSF340TPN provides a clearly identifiable and mechanically reliable means of isolating three-phase circuits without requiring access to the building’s main distribution board.

The operating handle is designed to remain securely in the off position once activated, helping reduce the risk of the circuit being unintentionally re-energised. Its durable enclosure, UV-resistant coating and IP65 protection make the switch well suited to exposed locations on commercial, retail and industrial buildings.

Typical Applications

  • Emergency isolation of illuminated signs and advertising displays.
  • Neon lighting installations.
  • Exterior building and architectural lighting.
  • Retail shopfront electrical systems.
  • Commercial property electrical installations.
  • Industrial buildings and warehouses.
  • Hotels, restaurants and entertainment venues.
  • Public buildings and transport facilities.
  • Three-phase equipment requiring externally accessible isolation.

Technical Specifications

Tick the specs you need, then view products that match.

Material Steel
Device Type Enclosed switch disconnector
Power 11 kW
Current 40 A
Phase Three Phase
IP Rating IP65
Manufacturer ABB
Series KSF
Model KSF340TPN
Product ID 2CMA142438R1000
Product type Enclosed fireman switch / switch disconnector
Number of switched poles 3
System type Five-wire system with fixed neutral and PE terminals
Rated switching current 40 A
Maximum operational voltage 690 V AC
Switching power approx. 15 kW
Electrical phase Three phase
Protection rating IP65
Enclosure material Rigid metal alloy
Enclosure colour Red
Handle type Side-operated fireman handle
Padlock compatibility Yes, one padlock
Terminal type Cable terminals
Internal terminal capacity up to 4 mm²
Top cable entries 2 × M25
Bottom cable entries 2 × M25 and 1 × M16
Installation Surface / wall mounting
Dimensions (H × W × D) approx. 168 × 138 × 68 mm
Standard IEC 60947-3
EAN 7392696424387

Frequently Asked Questions

What is the ABB 2CMA142438R1000 used for?

The ABB 2CMA142438R1000 is a fireman switch used to disconnect electrical power to equipment such as neon signs, illuminated advertising and exterior lighting during a fire or emergency.

What is the rated current of the ABB KSF340TPN?

The ABB KSF340TPN has a rated switching current of 40 A and can be used with operational voltages up to 690 V AC.

Can this fireman switch be installed outdoors?

Yes. The enclosure has an IP65 protection rating and a UV-protected finish, making it suitable for properly installed indoor and outdoor applications.

Does the KSF340TPN switch the neutral conductor?

No. The unit switches the three phase conductors and includes a fixed neutral terminal and a protective earth terminal for use in five-wire electrical systems.

Can the operating handle be padlocked?

Yes. The handle is designed to accept one padlock, helping prevent unauthorised operation or accidental re-energisation.

How is the fireman switch operated during an emergency?

The external handle is designed so emergency personnel can operate it using a fireman’s hook stick, allowing the connected circuit to be isolated quickly from a safe position.

Trusted for Emergency Isolation Applications

ABB KSF fireman switches provide visible, accessible and dependable electrical isolation for commercial and industrial buildings where emergency services may need to disconnect hazardous electrical equipment quickly.