1SCA022474R7150 ABB 315A 4-Pole Steel Enclosed Change-Over Switch

1SCA022474R7150 ABB 315A 4-Pole Steel Enclosed Change-Over Switch

ABB OT315KLAA4C is a 315 A four-pole steel-sheet enclosed I-O-II change-over switch with open top and bottom cable entries, designed for reliable manual supply selection, load switching and electrical isolation.

SKU: 1SCA022474R7150Alt SKU: OT315KLAA4CMPN: 1SCA022474R7150
Price
List Price £4,660.70 ex VAT
Your Price (ex VAT) Save 35%
£3,029.46 35% OFF
You save £1,631.25 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,029.46
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,029.46

Why Choose the ABB OT315KLAA4C 315A 4-Pole Enclosed Change-Over Switch?

The ABB OT315KLAA4C is a heavy-duty 315 A 4-pole steel-sheet enclosed change-over switch designed for dependable switching between two electrical supplies or circuits in industrial power distribution applications. Identified by ABB order code 1SCA022474R7150, it belongs to ABB product group 311019 – Metal Enclosed (Loadbreak) and combines ABB OT change-over switching technology with a robust steel-sheet enclosure.

Designed for high-current change-over applications, the OT315KLAA4C uses an I-O-II operating arrangement, providing two switched positions with a central OFF position. The enclosure is supplied with open cable entries at both the top and bottom, allowing C-flanges or ring-flange cable-entry components to be selected separately according to the installation requirements.

With a rated operational current of 315 A and a 4-pole configuration, the OT315KLAA4C is suitable for substantial low-voltage circuits where four conductors must be changed over simultaneously. Its steel-sheet enclosure, black pistol-type handle and integrated PE terminals provide a practical solution for industrial supply selection, transfer and change-over duties.

Key Advantages

  • Heavy-duty 315 A enclosed change-over switch for industrial power applications.
  • 4-pole configuration for simultaneous change-over of four conductors.
  • I-O-II switching arrangement provides two operating positions with a central OFF position.
  • Robust steel-sheet enclosure for demanding installations.
  • Open top and bottom cable entries provide flexible cabling options.
  • ABB OT load-break technology provides dependable manual supply selection and isolation.

Key Features

  • ABB OT enclosed change-over switch series.
  • 315 A rated operational current.
  • 4-pole configuration.
  • Steel-sheet enclosed construction.
  • I-O-II change-over operation.
  • Black pistol-type operating handle with I-O-II indication.
  • Open top and bottom cable entries.
  • Cable entries suitable for separately ordered C-flanges or ring-flanges.
  • PE terminals included.
  • 800 × 400 × 330 mm enclosure.
  • Designed for manual change-over, load switching and electrical isolation.

Reliable High-Current Supply Change-Over and Isolation

The ABB OT315KLAA4C provides a dependable method of manually selecting between two electrical supplies or circuits while incorporating a central OFF position for isolation. Its 315 A 4-pole configuration makes it particularly suitable for substantial low-voltage systems where four conductors need to be transferred together.

The steel-sheet enclosure is supplied with open top and bottom sides, allowing the installer to select suitable C-flange or ring-flange cable-entry accessories for the application. A black pistol-type handle provides clear I-O-II position indication, while included PE terminals support straightforward integration into industrial electrical installations.

Typical Applications

  • Manual mains and alternative-supply change-over.
  • Generator and mains supply selection.
  • Industrial power distribution systems.
  • Four-pole supply transfer applications.
  • Manufacturing and processing installations.
  • Industrial machinery and production equipment.
  • Manual source selection and electrical isolation.

Technical Specifications

Tick the specs you need, then view products that match.

Material Steel
Device Type Enclosed changeover switch
Series OT Enclosed Change-Over Switches
ABB order code 1SCA022474R7150
Product description 315A 4P steel enclosed change-over switch, open entry
Product type Steel-sheet enclosed change-over switch
ABB product group 311019 – Metal Enclosed (Loadbreak)
Rated operational current 315 A
Number of poles 4
Switching positions I-O-II
Enclosure material Steel sheet
Standard enclosure protection IP54
Cable entry Open top and bottom
Cable-entry accessories C-flanges or ring-flanges ordered separately
Handle Black pistol-type handle with I-O-II indication
PE terminals Included
Enclosure dimensions (H × W × D) 800 × 400 × 330 mm
Weight approx. 36 kg
Operation Manual
Application Electrical supply change-over, load switching and isolation

Frequently Asked Questions

What is the ABB OT315KLAA4C used for?

The OT315KLAA4C is a 315 A 4-pole enclosed change-over switch designed for manually changing between two electrical supplies or circuits while providing a central OFF position for isolation.

What is the rated current of the OT315KLAA4C?

The ABB OT315KLAA4C has a rated operational current of 315 A.

How many poles does the OT315KLAA4C have?

The OT315KLAA4C has a 4-pole configuration, allowing four conductors to be changed over simultaneously.

What switching positions does the OT315KLAA4C provide?

The OT315KLAA4C uses an I-O-II change-over arrangement, providing two switched operating positions with a central OFF position.

How are cables entered into the OT315KLAA4C enclosure?

The OT315KLAA4C is supplied with open top and bottom cable-entry sides. Suitable C-flanges or ring-flange cable-entry components are ordered separately to match the installation requirements.

Trusted ABB Switching Technology

ABB OT enclosed change-over switches provide dependable manual source selection, load switching and electrical isolation for industrial power distribution systems where robust construction, high-current capability and clear I-O-II operation are required.