Why Choose the IMO US10D3063A Miniature Circuit Breaker?

The IMO US10D3063A is a robust three-pole miniature circuit breaker and supplementary protector designed to provide dependable overcurrent protection within industrial control panels, machinery and automation systems. Part of the IMO US10 circuit protection range, it offers a compact and practical solution for protecting three-phase electrical circuits against overload and short-circuit conditions.

With a rated current of 63 A and a D curve tripping characteristic, the US10D3063A is particularly suitable for equipment that produces high inrush currents during start-up. This makes it an effective choice for motors, transformers, solenoids and other inductive industrial loads where a more tolerant instantaneous trip response is required.

The breaker features a space-efficient modular construction for installation on a standard 35 mm DIN rail. Its three mechanically linked poles provide simultaneous circuit isolation across three-phase systems, helping panel builders and machine manufacturers achieve reliable protection, convenient installation and straightforward maintenance.

Key Advantages

  • Compact three-pole circuit protection device for industrial applications.
  • 63 A rated current for higher-load electrical circuits.
  • D curve tripping characteristic suitable for equipment with high starting currents.
  • Provides protection against overload and short-circuit faults.
  • Mechanically linked poles support coordinated isolation of three-phase circuits.
  • DIN rail mounting enables quick installation inside control cabinets.

Key Features

  • IMO US10 circuit protection series.
  • 63 A rated current.
  • D curve operating characteristic.
  • Three-pole configuration.
  • Designed for AC industrial electrical systems.
  • Thermal and magnetic overcurrent protection.
  • Manual switching and circuit isolation capability.
  • Compact modular design for DIN rail installation.

Reliable Protection for High-Inrush Industrial Loads

The IMO US10D3063A uses thermal-magnetic operation to protect connected equipment from damaging electrical faults. The thermal element responds to sustained overload conditions, while the magnetic mechanism provides rapid disconnection when a significant short-circuit current is detected.

Its D curve characteristic permits a higher temporary inrush current than breakers with B or C curve characteristics. This helps reduce unnecessary tripping when motors, transformers and similar inductive equipment are energised, while maintaining reliable protection against genuine fault conditions.

Typical Applications

  • Industrial control panels and switchgear assemblies.
  • Three-phase motor and machinery circuits.
  • Transformers and inductive electrical loads.
  • Manufacturing and production equipment.
  • OEM automation systems.
  • Pumps, compressors and material handling machinery.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 1077
Current 63 A
Phase Three Phase
Poles 3-pole
Device Type MCB
Trip Curve D curve
Manufacturer IMO Precision Controls
Series US10
Model US10D3063A
Product type Miniature circuit breaker / supplementary protector
Rated current 63 A
Number of poles 3
Trip characteristic D Curve
Protection function Overload and short-circuit protection
Operating mechanism Thermal-magnetic
Application Three-phase AC circuits
Mounting type 35 mm DIN rail
Installation location Electrical control panel or enclosure
Reset type Manual reset
Connection type Screw terminals
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO US10D3063A used for?

The IMO US10D3063A is used to protect three-phase industrial circuits and connected equipment against overload and short-circuit conditions.

What is the rated current of the US10D3063A?

The breaker has a rated current of 63 A, making it suitable for higher-load industrial electrical circuits.

What does the D curve characteristic mean?

A D curve breaker permits relatively high temporary starting currents before its instantaneous magnetic trip operates, making it suitable for motors, transformers and other inductive loads.

How many poles does this circuit breaker have?

The US10D3063A has a three-pole configuration designed for coordinated protection and isolation of three-phase circuits.

How is the IMO US10D3063A installed?

The breaker is designed for mounting on a standard 35 mm DIN rail inside a suitable electrical panel or protective enclosure.

Trusted Circuit Protection for Industrial Systems

IMO circuit protection products are used by panel builders, machine manufacturers and automation professionals to provide practical installation, dependable operation and effective electrical protection in industrial control systems.