US10C1002A IMO 10kA UL1077 MCB 1 pole 2A C Curve

US10C1002A IMO 10kA UL1077 MCB 1 pole 2A C Curve

SKU: US10C1002AMPN: US10C1002A
Price
List Price £12.04 ex VAT
Your Price (ex VAT) Save 30%
£8.43 30% OFF
You save £3.61 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£8.43

Why Choose the IMO US10C1002A Supplementary Protector?

The IMO US10C1002A is a compact UL1077 supplementary protector designed to provide dependable overload and short circuit protection for electrical equipment and internal control circuits. Manufactured by IMO Precision Controls, this DIN rail-mounted protective device is ideal for industrial machinery, automation systems, OEM equipment and electrical control panels requiring reliable equipment-level protection.

Featuring a single-pole configuration, a 2 A rated current and a C curve tripping characteristic, the US10C1002A is ideal for protecting low-current circuits with moderate inrush requirements. Its thermal-magnetic operating mechanism provides dependable protection for PLCs, instrumentation, control devices, sensors, power supplies and other sensitive electrical equipment.

With a 10 kA short circuit breaking capacity, compact modular construction and DIN rail mounting, the US10C1002A delivers reliable fault protection while occupying minimal control panel space. It is designed for use as a supplementary protector alongside an appropriate upstream branch circuit protective device.

Key Advantages

  • Compact UL1077 supplementary protector for equipment-level circuit protection.
  • 2 A rated current suitable for low-current industrial control circuits.
  • C curve tripping characteristic accommodates moderate temporary inrush currents.
  • Single-pole configuration for individual circuit protection.
  • 10 kA breaking capacity provides dependable short circuit interruption.
  • DIN rail mounting simplifies installation and maintenance.

Key Features

  • IMO Precision Controls US10 series.
  • 2 A rated current.
  • C curve thermal-magnetic trip characteristic.
  • Single-pole supplementary protector.
  • 10 kA short circuit breaking capacity.
  • UL1077, IEC 60947-2 and IEC 60898-1 compliant.
  • Contact position indicator.
  • Compact DIN rail mounting.

Reliable Protection for Control and Equipment Circuits

Supplementary protectors automatically disconnect electrical circuits when excessive current is detected. The thermal element responds to sustained overload conditions, while the magnetic element provides rapid operation during short circuit faults. This helps protect internal wiring, sensitive electronic components and connected equipment from electrical damage.

The C curve characteristic of the IMO US10C1002A allows moderate temporary inrush currents before magnetic tripping occurs. This makes it suitable for control equipment and electrical devices that experience brief start-up currents while maintaining dependable protection against genuine electrical faults.

Typical Applications

  • Industrial control circuits.
  • PLC and automation systems.
  • Instrumentation and monitoring equipment.
  • Low-current power supply circuits.
  • Machine building and OEM equipment.
  • Internal equipment protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 1077
Current 2 A
Phase Single Phase
Poles 1-pole
Device Type MCB
Trip Curve C curve
Breaking Capacity 10 kA
Manufacturer IMO Precision Controls
Series US10 Supplementary Protectors
Model US10C1002A
Product type UL1077 supplementary protector
Rated current 2 A
Number of poles 1
Trip characteristic C Curve
Short circuit breaking capacity 10 kA
Trip mechanism Thermal-magnetic
Mounting type DIN rail mounting
Protection function Overload and short circuit protection
Application Equipment and internal control circuit protection
Suitable loads PLCs, instrumentation, power supplies and control circuits
Installation location Industrial control panels and electrical enclosures
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO US10C1002A used for?

The US10C1002A provides supplementary overload and short circuit protection for low-current circuits inside industrial machinery, automation equipment and electrical control panels.

What is the rated current of the US10C1002A?

The supplementary protector has a rated current of 2 A.

What does the C curve characteristic mean?

A C curve protective device accommodates moderate temporary inrush currents before magnetic tripping, making it suitable for PLCs, control devices and power supplies.

How many poles does this supplementary protector have?

The IMO US10C1002A has a single-pole configuration for protecting an individual electrical circuit.

Is the US10C1002A a branch circuit breaker?

No. The US10C1002A is a UL1077 supplementary protector intended for equipment-level protection and must be used with appropriate upstream branch circuit protection where required.

Trusted by Electrical Professionals Worldwide

IMO Precision Controls supplementary protectors are trusted by electrical engineers, panel builders and machine manufacturers for dependable equipment protection, compact installation and reliable long-term performance in industrial environments.