UB10D3002A IMO 10kA UL489 MCB 3 pole 2A D Curve

UB10D3002A IMO 10kA UL489 MCB 3 pole 2A D Curve

SKU: UB10D3002AMPN: UB10D3002A
Price
List Price £60.91 ex VAT
Your Price (ex VAT) Save 30%
£42.64 30% OFF
You save £18.27 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £42.64
Trade pricing is personalised to your account

Manufacturer Lead Time

£42.64

Why Choose the IMO UB10D3002A Miniature Circuit Breaker?

The IMO UB10D3002A is a high-performance 3-pole miniature circuit breaker (MCB) designed to protect three-phase electrical circuits against overloads and short circuits. As part of the trusted IMO UB10 circuit protection range, this D curve breaker is ideal for industrial automation systems, OEM machinery, control panels and commercial electrical installations requiring reliable circuit protection.

Its D curve tripping characteristic allows the breaker to accommodate high temporary inrush currents generated by motors, transformers, solenoids and other inductive equipment without nuisance tripping, while still providing rapid disconnection during fault conditions.

With a rated current of 2 A, a 3-pole configuration and a 10 kA breaking capacity, the UB10D3002A provides dependable protection for sensitive three-phase circuits. The compact DIN rail-mounted design enables quick installation in industrial control cabinets and distribution boards.

Key Advantages

  • Reliable overload and short-circuit protection.
  • 2 A rated current for low-current industrial circuits.
  • D curve tripping characteristic for inductive loads with high starting currents.
  • 3-pole configuration for complete three-phase protection.
  • 10 kA breaking capacity for dependable fault interruption.
  • Compact DIN rail-mounted design for straightforward installation.

Key Features

  • IMO UB10 miniature circuit breaker series.
  • 2 A rated operational current.
  • D curve trip characteristic.
  • 3-pole construction.
  • 10 kA short-circuit breaking capacity.
  • Thermo-magnetic overload and short-circuit protection.
  • Contact position indicator.
  • 35 mm DIN rail mounting.

Reliable Protection for Three-Phase Industrial Circuits

Miniature circuit breakers automatically disconnect electrical circuits whenever overload or short-circuit conditions occur, helping protect wiring, machinery and connected equipment from electrical damage. The thermo-magnetic mechanism combines dependable overload protection with rapid magnetic fault interruption.

The IMO UB10 series is widely specified for industrial automation, OEM machinery and commercial electrical installations. Its D curve characteristic is particularly suited to protecting motors, transformers, compressors and other inductive loads that generate high temporary starting currents.

Typical Applications

  • Industrial control panels.
  • Three-phase motor circuits.
  • Transformer protection.
  • Industrial automation systems.
  • OEM machinery.
  • Commercial electrical installations.
  • Distribution boards and switchboards.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 2 A
Phase Three Phase
Poles 3-pole
Device Type MCB
Trip Curve D curve
Breaking Capacity 10 kA
Manufacturer IMO Precision Controls
Series UB10 (B10 Range)
Model UB10D3002A
Product type Miniature circuit breaker (MCB)
Rated current 2 A
Number of poles 3
Trip characteristic D Curve
Rated voltage 230 / 400 V AC, maximum 60 V DC
Rated insulation voltage (Ui) 500 V
Rated frequency 50 / 60 Hz
Breaking capacity 10 kA
Standards IEC 60898-1, IEC 60947-2
Approvals CE, VDE, KEMA
Terminal capacity 1 to 25 mm²
Mounting type 35 mm DIN rail
Dimensions (H × W × D) 85.5 × 52.7 × 78 mm
Weight Approximately 0.3 kg
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO UB10D3002A used for?

It protects three-phase electrical circuits against overloads and short circuits, particularly circuits supplying motors, transformers and other inductive equipment with high starting currents.

What is the current rating?

The UB10D3002A has a 2 A rated current.

Why choose a D curve circuit breaker?

D curve breakers tolerate higher temporary inrush currents than B or C curve breakers, making them ideal for motors, transformers, compressors and other inductive loads.

What is the breaking capacity?

The breaker has a 10 kA short-circuit breaking capacity for dependable fault protection.

How is the UB10D3002A installed?

The breaker is designed for installation on a standard 35 mm DIN rail inside distribution boards, switchboards and industrial control panels.

Trusted Circuit Protection from IMO

IMO circuit protection products are trusted worldwide by electrical engineers, OEM manufacturers and panel builders for dependable overload protection, straightforward installation and long-term reliability in demanding industrial environments.