UB10D2007A IMO 10kA UL489 MCB 2 pole 7A D Curve

UB10D2007A IMO 10kA UL489 MCB 2 pole 7A D Curve

SKU: UB10D2007AMPN: UB10D2007A
Price
List Price £40.63 ex VAT
Your Price (ex VAT) Save 30%
£28.44 30% OFF
You save £12.19 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.44

Why Choose the IMO UB10D2007A Miniature Circuit Breaker?

The IMO UB10D2007A is an industrial UL 489 miniature circuit breaker (MCB) designed to provide dependable overload and short-circuit protection for machinery, automation equipment and electrical control panels. Manufactured by IMO Precision Controls, this two-pole circuit breaker uses thermo-magnetic protection to help safeguard conductors and connected equipment against excessive current.

As part of the established IMO UB10 miniature circuit breaker series, the UB10D2007A features a D curve tripping characteristic. Its instantaneous magnetic trip range of approximately 10 to 20 times the rated current makes it suitable for motors, transformers, solenoids and other inductive loads that can generate high starting currents.

With a rated operational current of 7 A, a two-pole configuration and a 10 kA short-circuit breaking capacity, the UB10D2007A delivers reliable industrial branch circuit protection in a compact DIN rail format. It is suitable for machine-building applications, OEM automation systems and industrial electrical distribution assemblies.

Key Advantages

  • Industrial UL 489 miniature circuit breaker.
  • 7 A rated operational current.
  • Two-pole configuration for simultaneous circuit isolation.
  • D curve tripping characteristic for high inrush current loads.
  • 10 kA short-circuit breaking capacity.
  • Thermo-magnetic overload and short-circuit protection.
  • Compact DIN rail design for straightforward panel installation.

Key Features

  • IMO UB10 miniature circuit breaker series.
  • 7 A rated current.
  • Two-pole design.
  • D curve operating characteristic.
  • 10 kA rated breaking capacity.
  • Designed to meet UL 489, IEC 60947-2 and IEC 60898-1.
  • Contact-position indicator for convenient status identification.
  • DIN rail mounting for industrial electrical enclosures.

Reliable Protection for Industrial Electrical Systems

Miniature circuit breakers automatically disconnect electrical circuits when overloads or short circuits occur. The thermal mechanism responds to sustained excess current, while the magnetic mechanism provides rapid interruption during severe fault conditions, helping to protect wiring, machinery and connected electrical equipment.

The D curve characteristic of the IMO UB10D2007A accommodates temporary current surges generated when motors, transformers and other inductive equipment are energised. This helps reduce nuisance tripping during normal start-up while maintaining dependable protection against genuine electrical faults.

Typical Applications

  • Industrial control panels and electrical cabinets.
  • Transformers, solenoids and inductive loads.
  • Motor control and machinery circuits.
  • OEM automation equipment.
  • Manufacturing and production machinery.
  • Two-pole industrial branch circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 7 A
Poles 2-pole
Device Type MCB
Trip Curve D curve
Breaking Capacity 10 kA
Manufacturer IMO Precision Controls
Series UB10
Model UB10D2007A
Product type Miniature circuit breaker (MCB)
Rated operational current 7 A
Number of poles 2
Tripping characteristic D Curve
Instantaneous tripping range 10–20 × rated current
Rated short-circuit breaking capacity 10 kA
UL rated operational voltage 480Y/277 V AC
IEC rated operational voltage 415 V AC
DC rated operational voltage 96 V DC
Rated operational frequency 50 / 60 Hz
Standards UL 489, IEC 60947-2 and IEC 60898-1
Protection degree NEMA 1 / IP20
Mounting type DIN rail EN 60715
Mechanical lifetime 20,000 operations
Electrical lifetime 6,000 operations
Operating temperature -25°C to +55°C
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO UB10D2007A used for?

The IMO UB10D2007A provides overload and short-circuit protection for industrial electrical circuits, machinery, automation equipment and control-panel applications.

What current rating does this circuit breaker have?

The UB10D2007A has a rated operational current of 7 A.

How many poles does the UB10D2007A have?

This model is a two-pole miniature circuit breaker, allowing two circuit conductors to be disconnected simultaneously.

What does the D curve characteristic mean?

The D curve provides instantaneous magnetic tripping at approximately 10 to 20 times the rated current, making the breaker suitable for motors, transformers and other inductive equipment with high starting currents.

What is the breaking capacity of the UB10D2007A?

The circuit breaker has a rated short-circuit breaking capacity of 10 kA.

Trusted Industrial Circuit Protection

IMO Precision Controls miniature circuit breakers provide dependable overload and short-circuit protection for machine builders, panel manufacturers and industrial automation applications.