UB10C3003A IMO 10kA UL489 MCB 3 pole 3A C Curve

UB10C3003A IMO 10kA UL489 MCB 3 pole 3A C Curve

SKU: UB10C3003AMPN: UB10C3003A
Price
List Price £60.91 ex VAT
Your Price (ex VAT) Save 30%
£42.64 30% OFF
You save £18.27 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £42.64
Trade pricing is personalised to your account

Manufacturer Lead Time

£42.64

Why Choose the IMO UB10C3003A UL489 Miniature Circuit Breaker?

The IMO UB10C3003A is a compact UL489 miniature circuit breaker (MCB) designed to protect low-current industrial branch circuits against overloads and short circuits. Manufactured by IMO Precision Controls, it provides dependable circuit protection for industrial control panels, automation equipment, instrumentation and OEM machinery.

The UB10C3003A combines thermomagnetic protection with a modular DIN rail-mounted design for straightforward integration into electrical enclosures. Its three-pole construction enables three connected conductors to be switched, protected and isolated simultaneously, making it suitable for three-phase control and distribution circuits.

Featuring a 3 A rated current, 3-pole configuration, C curve tripping characteristic and 10 kA short circuit interrupting capacity, the UB10C3003A provides effective protection for low-current industrial circuits that may experience moderate temporary inrush currents.

Key Advantages

  • Dependable overload and short circuit protection.
  • 3 A current rating for low-current industrial circuits.
  • 3-pole configuration provides simultaneous protection and isolation.
  • C curve tripping characteristic accommodates moderate inrush currents.
  • 10 kA interrupting capacity provides robust fault protection.
  • Compact DIN rail-mounted construction simplifies panel installation.

Key Features

  • IMO UB10 UL489 miniature circuit breaker.
  • 3 A rated current.
  • 3-pole construction.
  • C curve trip characteristic.
  • 10 kA short circuit interrupting capacity.
  • Thermomagnetic overload and short circuit protection.
  • Manual switching and circuit isolation capability.
  • Compact DIN rail mounting for industrial control panels.

Reliable Protection for Low-Current Three-Phase Circuits

Miniature circuit breakers automatically disconnect electrical circuits when excessive current is detected, helping protect cables, control devices and connected equipment. Thermomagnetic operation provides delayed tripping during sustained overload conditions and rapid interruption when a high-current short circuit occurs.

The IMO UB10C3003A is designed for industrial installations where dependable low-current protection, convenient manual resetting and compact panel integration are required. Its C curve characteristic makes it suitable for circuits containing contactors, transformers, power supplies and other equipment with moderate starting currents.

Typical Applications

  • Industrial control and automation panels.
  • PLC and controller power circuits.
  • Instrumentation and monitoring equipment.
  • Three-phase control circuits.
  • OEM machinery and production equipment.
  • Industrial branch circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 3 A
Phase Three Phase
Poles 3-pole
Device Type MCB
Trip Curve C curve
Manufacturer IMO Precision Controls
Series UB10 UL489 Circuit Breakers
Model UB10C3003A
Product type UL489 miniature circuit breaker
Rated current 3 A
Number of poles 3
Trip characteristic C Curve
Short circuit interrupting capacity 10 kA
Protection method Thermomagnetic
Protection functions Overload and short circuit protection
Mounting type DIN rail
Installation location Electrical control panel or distribution enclosure
Applicable standard UL489
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO UB10C3003A used for?

It protects low-current industrial control, automation and three-phase branch circuits against overloads and short circuits.

What is the current rating of the UB10C3003A?

The IMO UB10C3003A has a rated current of 3 A.

How many poles does this circuit breaker have?

This circuit breaker has a 3-pole configuration, allowing three conductors to be protected and isolated simultaneously.

What does the C curve trip characteristic mean?

A C curve circuit breaker accommodates moderate temporary inrush currents whilst providing dependable protection against sustained overloads and short circuits.

How is the IMO UB10C3003A installed?

The circuit breaker is designed for mounting on a standard DIN rail inside an industrial control panel or electrical distribution enclosure.

Trusted for Industrial Circuit Protection

IMO circuit protection products are used by machine builders, panel manufacturers and automation engineers to protect industrial equipment, control systems and electrical distribution circuits.