UB10C201.6A IMO 10kA UL489 MCB 2 pole 1.6A C Curve

UB10C201.6A IMO 10kA UL489 MCB 2 pole 1.6A C Curve

SKU: UB10C201.6AMPN: UB10C201.6A
Price
List Price £40.63 ex VAT
Your Price (ex VAT) Save 30%
£28.44 30% OFF
You save £12.19 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.44

Why Choose the IMO UB10C201.6A Miniature Circuit Breaker?

The IMO UB10C201.6A is a compact UL 489 miniature circuit breaker (MCB) engineered to provide reliable protection against overloads and short circuits in industrial and commercial electrical installations. As part of the IMO UB10 Series, this two-pole circuit breaker delivers dependable branch circuit protection for control panels, OEM machinery, automation systems and electrical distribution equipment.

Featuring a 1.6 A rated current, a 2-pole configuration, a C curve trip characteristic and a 10 kA short-circuit breaking capacity, the UB10C201.6A is ideal for protecting control circuits, instrumentation, PLC systems, control transformers and other equipment with moderate inrush currents. Its mechanically linked poles ensure both conductors disconnect simultaneously during overload or fault conditions.

The thermal-magnetic operating mechanism combines dependable overload protection with rapid short-circuit interruption, helping to minimise equipment damage and costly downtime. Its compact DIN rail design enables quick installation inside industrial control panels and electrical enclosures.

Key Advantages

  • Compact UL 489 miniature circuit breaker for branch circuit protection.
  • 1.6 A rated current ideal for low-current industrial control circuits.
  • Two-pole linked configuration disconnects both conductors simultaneously.
  • C curve trip characteristic accommodates moderate inrush currents.
  • 10 kA short-circuit breaking capacity provides dependable fault protection.
  • Standard DIN rail mounting enables quick installation.

Key Features

  • IMO UB10 Series.
  • 1.6 A rated current.
  • Two-pole (2P) configuration.
  • C curve tripping characteristic.
  • 10 kA short-circuit interrupting capacity.
  • UL 489 approved branch circuit protection.
  • Thermal overload and magnetic short-circuit protection.
  • Compact DIN rail mounted construction.

Reliable Protection for Industrial Control Circuits

Miniature circuit breakers automatically disconnect electrical circuits when overload or short-circuit conditions occur. The thermal trip element responds to sustained overloads, while the magnetic mechanism rapidly interrupts fault currents, helping protect wiring, control equipment and sensitive electrical devices.

The IMO UB10 Series is trusted by panel builders, machine manufacturers and industrial electricians who require compact, dependable branch circuit protection. The UB10C201.6A is particularly suited to applications requiring simultaneous isolation of two conductors while accommodating moderate inrush currents.

Typical Applications

  • Industrial control panels.
  • PLC and automation systems.
  • Control transformers.
  • Instrumentation and monitoring equipment.
  • OEM machinery.
  • Commercial and industrial distribution boards.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 1.6 A
Poles 2-pole
Device Type MCB
Trip Curve C curve
Breaking Capacity 10 kA
Manufacturer IMO Precision Controls
Series UB10
Model UB10C201.6A
Product type Miniature circuit breaker (MCB)
Rated current 1.6 A
Number of poles 2 poles
Trip characteristic C curve
Short-circuit breaking capacity 10 kA
Rated voltage 480Y/277 V AC, 96 V DC
Frequency 50/60 Hz
Mounting type 35 mm DIN rail (EN 60715)
Trip mechanism Fixed thermal / fixed magnetic
Protection rating IP20 (NEMA 1)
Mechanical life 20,000 operations
Electrical life 6,000 operations
Standards UL 489, IEC 60947-2, IEC 60898-1
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO UB10C201.6A used for?

The UB10C201.6A protects industrial electrical circuits, control equipment and wiring against overloads and short circuits.

What is the current rating of the UB10C201.6A?

The circuit breaker has a rated current of 1.6 A.

How many poles does this circuit breaker have?

The UB10C201.6A has a 2-pole configuration, allowing both conductors to disconnect simultaneously during a fault.

What does the C curve trip characteristic mean?

A C curve breaker is designed for circuits with moderate inrush currents, making it suitable for industrial control equipment, transformers and automation systems.

How is the UB10C201.6A installed?

The breaker mounts directly onto a standard 35 mm DIN rail inside electrical control panels and distribution boards.

Trusted by Industrial Electrical Professionals

IMO Precision Controls circuit protection products are trusted worldwide by OEMs, panel builders and industrial electricians for dependable performance, robust construction and reliable branch circuit protection.