UB10C2008A IMO 10kA UL489 MCB 2 pole 8A C Curve

UB10C2008A IMO 10kA UL489 MCB 2 pole 8A C Curve

SKU: UB10C2008AMPN: UB10C2008A
Price
List Price £40.63 ex VAT
Your Price (ex VAT) Save 30%
£28.44 30% OFF
You save £12.19 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £28.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.44

Why Choose the IMO UB10C2008A Miniature Circuit Breaker?

The IMO UB10C2008A is a compact UL 489 miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the IMO UB10 Series, this two-pole circuit breaker provides dependable branch circuit protection for industrial control panels, machinery, automation equipment and electrical distribution systems.

Featuring an 8 A rated current, a two-pole configuration, a C curve trip characteristic and a 10 kA short-circuit interrupting capacity, the UB10C2008A is suitable for control, auxiliary and instrumentation circuits that may experience moderate start-up currents. Its linked two-pole construction allows both connected conductors to be disconnected simultaneously when an overload or short circuit occurs.

The UB10C2008A combines thermal overload protection with rapid magnetic short-circuit protection, helping to safeguard wiring, power supplies and connected electrical equipment. Its compact DIN rail mounting format supports efficient installation inside OEM machinery, industrial control panels and distribution enclosures.

Key Advantages

  • Compact UL 489 miniature circuit breaker for branch circuit protection.
  • 8 A rated current for industrial control and auxiliary circuits.
  • Two-pole linked configuration disconnects both conductors simultaneously.
  • C curve trip characteristic accommodates moderate inrush currents.
  • 10 kA short-circuit interrupting capacity provides dependable fault protection.
  • DIN rail mounting enables straightforward installation inside electrical panels.

Key Features

  • IMO UB10 Series.
  • 8 A rated current.
  • Two-pole (2P) configuration.
  • C curve tripping characteristic.
  • 10 kA short-circuit interrupting capacity.
  • UL 489 branch circuit protection.
  • Thermal overload and magnetic short-circuit protection.
  • Compact construction for DIN rail installation.

Reliable Protection for Industrial Control Circuits

Miniature circuit breakers automatically disconnect electrical circuits when excessive current is detected. The thermal trip mechanism responds to sustained overload conditions, while the magnetic trip mechanism provides rapid isolation during high-current short circuits. This combined operation helps reduce the risk of damage to wiring and connected electrical equipment.

The C curve operating characteristic enables the UB10C2008A to accommodate moderate momentary inrush currents while maintaining effective overload and short-circuit protection. Its two-pole construction makes it suitable for circuits requiring simultaneous disconnection of both conductors.

Typical Applications

  • Industrial control and auxiliary circuits.
  • PLC and automation systems.
  • Instrumentation and monitoring equipment.
  • Control transformers and power supplies.
  • OEM machinery and electrical control panels.
  • Commercial and industrial distribution equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 8 A
Poles 2-pole
Device Type MCB
Trip Curve C curve
Manufacturer IMO Precision Controls
Series UB10
Model UB10C2008A
Product type Miniature circuit breaker (MCB)
Rated current 8 A
Number of poles 2 poles
Trip characteristic C curve
Short-circuit interrupting capacity 10 kA
Trip mechanism Thermal-magnetic
Mounting type DIN rail
Utilisation Branch circuit protection
Applicable standard UL 489
HS Code 8536201090
Country of Manufacture India

Frequently Asked Questions

What is the IMO UB10C2008A used for?

The UB10C2008A protects electrical circuits, wiring and connected control equipment against overloads and short circuits in industrial and commercial installations.

What is the current rating of the UB10C2008A?

The circuit breaker has a rated current of 8 A.

How many poles does this circuit breaker have?

The UB10C2008A has a two-pole configuration, enabling both connected conductors to be disconnected simultaneously.

What does the C curve trip characteristic mean?

A C curve circuit breaker accommodates moderate start-up currents while providing reliable overload and short-circuit protection.

What is the short-circuit interrupting capacity?

The IMO UB10C2008A has a 10 kA short-circuit interrupting capacity.

How is the IMO UB10C2008A installed?

The circuit breaker is designed for DIN rail installation inside an electrical control panel, machinery enclosure or distribution board.

Designed for Industrial Electrical Professionals

IMO UB10 circuit breakers provide compact thermal-magnetic protection for panel builders, machine manufacturers and electrical engineers working with industrial automation, machinery and branch circuits.