S202-C40 Miniature Circuit Breaker - 2P - C - 40 A

S202-C40 Miniature Circuit Breaker – 2P – C – 40 A

ABB S202-C40 two-pole miniature circuit breaker with a 40 A rated current, C curve tripping characteristic and 6 kA rated breaking capacity for overload and short-circuit protection.

SKU: S202C40Alt SKU: S202-C40MPN: 2CDS252001R0404
Price
List Price £55.79 ex VAT
Your Price (ex VAT) Save 45%
£30.68 45% OFF
You save £25.11 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30.68
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 5

£30.68

Why Choose the ABB S202-C40 Miniature Circuit Breaker?

The ABB S202-C40 is a dependable two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the established ABB System pro M Compact S200 series, it provides current-limiting protection for residential, commercial and industrial electrical distribution systems.

The S202-C40 uses two complementary tripping mechanisms. A delayed thermal mechanism responds to sustained overloads, while an electromagnetic mechanism provides rapid disconnection during short-circuit conditions. This helps protect cables, switchgear and connected equipment from damaging overcurrents.

With a 40 A rated current, C curve tripping characteristic, two-pole configuration and 6 kA rated breaking capacity, the ABB S202-C40 is suitable for correctly designed circuits with moderate inrush currents. Typical uses include commercial distribution boards, HVAC equipment, pumps, motors, industrial control panels and general-purpose power distribution.

Key Advantages

  • Reliable two-pole overload and short-circuit protection.
  • 40 A rated current for higher-load electrical circuits.
  • C curve characteristic suitable for moderate starting currents.
  • 6 kA rated breaking capacity according to IEC/EN 60898-1.
  • Simultaneous switching and protection of two conductors.
  • Compatible with ABB System pro M Compact accessories and auxiliary contacts.

Key Features

  • ABB System pro M Compact S200 series.
  • 40 A rated current.
  • Two-pole (2P) configuration.
  • C tripping characteristic.
  • 6 kA rated short-circuit capacity.
  • Thermal overload protection.
  • Electromagnetic short-circuit protection.
  • Contact-position indication with red ON and green OFF markings.
  • Standard 35 mm DIN rail mounting.

Reliable Protection for Higher-Current Circuits

The ABB S202-C40 automatically disconnects a circuit when an overload or short circuit occurs. Its thermal trip responds to prolonged overcurrent, while the electromagnetic trip rapidly interrupts high fault currents to help minimise damage to electrical wiring and connected equipment.

The C curve characteristic provides tolerance for moderate temporary inrush currents while maintaining effective fault protection. This makes the S202-C40 suitable for circuits supplying HVAC systems, pumps, motors, commercial equipment and industrial machinery, provided the breaker rating and cable size have been selected by a qualified electrical professional.

Typical Applications

  • Commercial distribution boards.
  • Industrial switchboards.
  • HVAC and ventilation equipment.
  • Pumps and small motors.
  • Industrial control panels.
  • OEM machinery.
  • Workshop equipment.
  • General-purpose power distribution circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Breaking Capacity 6 kA
Current 40 A
Phase Single Phase
Poles 2-pole
Device Type MCB
Trip Curve C curve
Manufacturer ABB
Series System pro M Compact S200
Model S202-C40
Manufacturer part number 2CDS252001R0404
EAN 4016779466301
Product type Miniature circuit breaker (MCB)
Rated current 40 A
Number of poles 2
Number of protected poles 2
Tripping characteristic C
Rated breaking capacity (Icn) 6 kA at 230 / 400 V AC
Ultimate short-circuit breaking capacity (Icu) 20 kA at 230 V AC and 10 kA at 400 V AC
Rated operational voltage 230 / 400 V AC
Maximum operational voltage 440 V AC
Rated DC voltage 125 V DC
Frequency 50 / 60 Hz
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy-limiting class 3
Protection rating IP20
Electrical endurance 10,000 operating cycles
Mechanical endurance 20,000 operating cycles
Terminal tightening torque 2.8 N·m
Mounting type 35 mm DIN rail
Module width 2 modules
Dimensions (H × W × D) approximately 88 × 35 × 69 mm
Weight approximately 0.25 kg
Standards IEC/EN 60898-1, IEC/EN 60947-2 and UL 1077
HS Code 85362010
Country of Manufacture Germany

Frequently Asked Questions

What is the ABB S202-C40 used for?

The ABB S202-C40 protects higher-current electrical circuits against overloads and short circuits in commercial, industrial and suitable residential installations.

What does the C curve tripping characteristic mean?

A C curve miniature circuit breaker is designed to tolerate moderate temporary inrush currents, making it suitable for equipment such as HVAC systems, pumps, transformers and motors.

What is the rated current of the ABB S202-C40?

The ABB S202-C40 has a rated current of 40 A.

How many poles does the ABB S202-C40 have?

The S202-C40 is a two-pole miniature circuit breaker, allowing two conductors to be protected and disconnected simultaneously.

What is the breaking capacity of the ABB S202-C40?

The ABB S202-C40 has a rated short-circuit breaking capacity of 6 kA according to IEC/EN 60898-1.

How is the ABB S202-C40 installed?

The circuit breaker is designed for installation on a standard 35 mm DIN rail inside a suitable distribution board, switchboard or electrical control panel.

Trusted by Electrical Professionals Worldwide

ABB System pro M Compact miniature circuit breakers are widely specified by electricians, engineers and panel builders for dependable circuit protection, compact installation and compatibility with modern electrical distribution systems.