Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S-ARC1 M C20 (2CSA275901R9204) arc fault detection device with integrated MCB: 1P+N, C curve, 20 A, 10 kA breaking capacity.
£175.00
The ABB S-ARC1 M C20 is a compact and reliable arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to protect low-voltage electrical circuits against dangerous arc faults, overloads and short circuits. As part of the ABB S-ARC1 M series, it combines arc fault detection and overcurrent protection in a space-saving two-module device for residential, commercial and other building electrical installations.
The S-ARC1 M C20 monitors the electrical circuit for characteristics associated with hazardous arc faults and disconnects the affected circuit when necessary. Its integrated MCB provides conventional overload and short-circuit protection, allowing multiple protective functions to be incorporated within a single DIN rail device and helping simplify electrical distribution-board design.
With a rated current of 20 A, a C tripping characteristic and a 10 kA ultimate short-circuit breaking capacity, the S-ARC1 M C20 is suitable for circuits where moderate starting or inrush currents may occur. It operates at 230–240 V AC and its compact 1P+N configuration occupies only two modules within the distribution board.
Arc faults can develop as a result of damaged conductors, deteriorated insulation, loose electrical connections and other electrical installation faults. Because some dangerous arcing conditions may not draw sufficient current to operate conventional overcurrent protection, an AFDD monitors the circuit for electrical characteristics associated with hazardous arcs and disconnects the affected circuit when required.
The ABB S-ARC1 M series combines arc fault detection technology with an integrated miniature circuit breaker. The S-ARC1 M C20 therefore provides arc fault, overload and short-circuit protection within a compact two-module enclosure, helping simplify modern electrical distribution-board design while providing enhanced protection against electrically induced fires.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 20 A | |
| Trip Curve | C curve | |
| Breaking Capacity | 10 kA | |
| Phase | Single Phase | |
| Manufacturer | ABB | |
| Series | S-ARC1 M | |
| Model | S-ARC1 M C20 | |
| Order code | 2CSA275901R9204 | |
| Product type | Arc fault detection device (AFDD) with integrated MCB | |
| Rated current | 20 A | |
| Tripping characteristic | C | |
| Rated operating voltage | 230–240 V AC | |
| Rated frequency | 50–60 Hz | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Ultimate short-circuit breaking capacity (Icu) | 10 kA | |
| Service short-circuit breaking capacity (Ics) | 7.5 kA | |
| Rated insulation voltage | 500 V | |
| Rated impulse withstand voltage | 4 kV | |
| Power loss | 3.6 W | |
| Standards | IEC/EN 62606, IEC/EN 60898-1 | |
| Mounting type | DIN rail mounting | |
| Terminal type | Screw terminals | |
| Terminal tightening torque | 2.8 N·m | |
| Terminal protection rating | IP20 | |
| Housing protection rating | IP40 | |
| Pollution degree | 2 | |
| Width | 2 modules / 35 mm | |
| Dimensions (H × W × D) | 85 × 35 × 69 mm | |
| Weight | 0.18 kg | |
| Ambient operating temperature | -25 to +55 °C |
The ABB S-ARC1 M C20 is used to protect low-voltage electrical circuits against arc faults, overloads and short circuits in residential, commercial and other building electrical installations.
The device has a rated current of 20 A and uses a C tripping characteristic.
The ABB S-ARC1 M C20 has an ultimate short-circuit breaking capacity of 10 kA and a service short-circuit breaking capacity of 7.5 kA.
Yes. The S-ARC1 M C20 combines an arc fault detection device (AFDD) with an integrated miniature circuit breaker (MCB), providing arc fault detection together with overload and short-circuit protection.
The device is designed for DIN rail mounting and occupies two modules, with an overall width of 35 mm.
ABB S-ARC1 M arc fault detection devices combine advanced arc fault monitoring with proven miniature circuit breaker technology, providing compact protection against arc faults, overloads and short circuits in modern low-voltage electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.