ABB S-ARC1 M B6 (2CSA275901R9065) arc fault detection device with integrated MCB: 1P+N, B curve, 6 A, 10 kA breaking capacity.
£162.72
The ABB S-ARC1 M B6 is a compact and reliable arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to protect low-voltage electrical circuits against dangerous arc faults, overloads and short circuits. As part of the ABB S-ARC1 M series, it combines advanced arc fault detection with conventional overcurrent protection in a space-saving two-module device for residential, commercial and other building electrical installations.
The S-ARC1 M B6 continuously monitors the electrical circuit for characteristics associated with hazardous series, parallel and earth arc faults and disconnects the affected circuit when necessary. Its integrated thermal-magnetic MCB also provides overload and short-circuit protection, while a continuous internal self-test and LED indication support reliable operation and easier troubleshooting.
With a rated current of 6 A, a B tripping characteristic and a 10 kA rated short-circuit breaking capacity, the S-ARC1 M B6 is well suited to lower-current final circuits requiring enhanced protection. It operates at 230–240 V AC and its compact 1P+N configuration occupies only two modules within a standard DIN rail distribution board.
Arc faults can develop as a result of damaged conductors, deteriorated insulation, loose electrical connections and other installation faults. Because some dangerous arcing conditions may not draw sufficient current to operate conventional overcurrent protection, an AFDD monitors the circuit for electrical characteristics associated with hazardous arcs and disconnects the affected circuit when required.
The ABB S-ARC1 M series combines arc fault detection technology with an integrated miniature circuit breaker. The S-ARC1 M B6 therefore provides protection against series, parallel and earth arc faults as well as overloads and short circuits within a compact two-module enclosure, helping simplify modern electrical distribution-board design.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 6 A | |
| Trip Curve | B curve | |
| Breaking Capacity | 10 kA | |
| Phase | Single Phase | |
| Manufacturer | ABB | |
| Series | S-ARC1 M | |
| Model | S-ARC1 M B6 | |
| Order code | 2CSA275901R9065 | |
| Product type | Arc fault detection device (AFDD) with integrated MCB | |
| Rated current | 6 A | |
| Tripping characteristic | B | |
| Rated voltage | 230–240 V AC | |
| Rated frequency | 50 / 60 Hz | |
| Minimum operating voltage | 170 V AC | |
| Number of poles | 1P+N | |
| Rated short-circuit breaking capacity | 10 kA | |
| Overvoltage protection threshold | 275 V AC | |
| Standards | IEC/EN 62606, IEC/EN 60898-1 | |
| Mounting type | DIN rail mounting | |
| Width | 2 modules / 35 mm | |
| Dimensions (H × W × D) | 85 × 35 × 69 mm | |
| Weight | approx. 0.18 kg | |
| Terminal protection rating | IP20 | |
| Ambient operating temperature | -25 to +55 °C | |
| Storage temperature | -40 to +70 °C | |
| Maximum conductor capacity | 25 mm² | |
| Maximum busbar cross-section | 10 mm² | |
| Terminal tightening torque | 2.8 N·m |
The ABB S-ARC1 M B6 is used to protect low-voltage electrical circuits against arc faults, overloads and short circuits in residential, commercial and other building electrical installations.
The device has a rated current of 6 A and uses a B tripping characteristic.
The ABB S-ARC1 M B6 has a rated short-circuit breaking capacity of 10 kA.
Yes. The S-ARC1 M B6 combines an arc fault detection device (AFDD) with an integrated miniature circuit breaker (MCB), providing arc fault detection together with overload and short-circuit protection.
The device is designed for DIN rail mounting and occupies two modules, with an overall width of 35 mm. The supply can be connected from either the top or bottom.
ABB S-ARC1 M arc fault detection devices combine advanced arc fault monitoring with proven miniature circuit breaker technology, providing compact protection against arc faults, overloads and short circuits in modern low-voltage electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.