S-ARC1 M B6 Arc Fault Detection Device (AFDD) with MCB - 1P+N - B - 6 A - 10 kA

S-ARC1 M B6 Arc Fault Detection Device (AFDD) with MCB – 1P+N – B – 6 A – 10 kA

ABB S-ARC1 M B6 (2CSA275901R9065) arc fault detection device with integrated MCB: 1P+N, B curve, 6 A, 10 kA breaking capacity.

SKU: S-ARC1 M B6Alt SKU: 2CSA275901R9065MPN: 2CSA275901R9065
Price
List Price £232.45 ex VAT
Your Price (ex VAT) Save 30%
£162.72 30% OFF
You save £69.74 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £162.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£162.72

Why Choose the ABB S-ARC1 M B6 Arc Fault Detection Device?

The ABB S-ARC1 M B6 is a compact and reliable arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to protect low-voltage electrical circuits against dangerous arc faults, overloads and short circuits. As part of the ABB S-ARC1 M series, it combines advanced arc fault detection with conventional overcurrent protection in a space-saving two-module device for residential, commercial and other building electrical installations.

The S-ARC1 M B6 continuously monitors the electrical circuit for characteristics associated with hazardous series, parallel and earth arc faults and disconnects the affected circuit when necessary. Its integrated thermal-magnetic MCB also provides overload and short-circuit protection, while a continuous internal self-test and LED indication support reliable operation and easier troubleshooting.

With a rated current of 6 A, a B tripping characteristic and a 10 kA rated short-circuit breaking capacity, the S-ARC1 M B6 is well suited to lower-current final circuits requiring enhanced protection. It operates at 230–240 V AC and its compact 1P+N configuration occupies only two modules within a standard DIN rail distribution board.

Key Advantages

  • Combines arc fault detection and miniature circuit breaker protection in one device.
  • 6 A rated current with B tripping characteristic.
  • 10 kA short-circuit breaking capacity for robust circuit protection.
  • Provides protection against series, parallel and earth arc faults.
  • Integrated MCB provides overload and short-circuit protection.
  • Continuous internal self-test helps verify correct AFDD operation.
  • Compact 1P+N two-module design helps conserve distribution-board space.

Key Features

  • ABB S-ARC1 M series AFDD with integrated MCB.
  • 6 A rated current.
  • B tripping characteristic.
  • 10 kA rated short-circuit breaking capacity.
  • 230–240 V AC rated voltage.
  • 50 / 60 Hz rated frequency.
  • 1P+N configuration.
  • Integrated test push button and continuous internal self-test.
  • Contact position and AFDD trip indication for easier troubleshooting.
  • Flexible power supply connection from either the top or bottom.
  • Compatible with ABB System pro M compact accessories and busbars.

Reliable Arc Fault and Circuit Protection

Arc faults can develop as a result of damaged conductors, deteriorated insulation, loose electrical connections and other installation faults. Because some dangerous arcing conditions may not draw sufficient current to operate conventional overcurrent protection, an AFDD monitors the circuit for electrical characteristics associated with hazardous arcs and disconnects the affected circuit when required.

The ABB S-ARC1 M series combines arc fault detection technology with an integrated miniature circuit breaker. The S-ARC1 M B6 therefore provides protection against series, parallel and earth arc faults as well as overloads and short circuits within a compact two-module enclosure, helping simplify modern electrical distribution-board design.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial buildings and offices.
  • Lighting circuits requiring 6 A B-curve protection.
  • Control and auxiliary electrical circuits.
  • Final circuits requiring enhanced protection against electrical arc faults.
  • Buildings containing valuable or difficult-to-replace assets.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type AFDD
Poles 1-pole + N
Current 6 A
Trip Curve B curve
Breaking Capacity 10 kA
Phase Single Phase
Manufacturer ABB
Series S-ARC1 M
Model S-ARC1 M B6
Order code 2CSA275901R9065
Product type Arc fault detection device (AFDD) with integrated MCB
Rated current 6 A
Tripping characteristic B
Rated voltage 230–240 V AC
Rated frequency 50 / 60 Hz
Minimum operating voltage 170 V AC
Number of poles 1P+N
Rated short-circuit breaking capacity 10 kA
Overvoltage protection threshold 275 V AC
Standards IEC/EN 62606, IEC/EN 60898-1
Mounting type DIN rail mounting
Width 2 modules / 35 mm
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight approx. 0.18 kg
Terminal protection rating IP20
Ambient operating temperature -25 to +55 °C
Storage temperature -40 to +70 °C
Maximum conductor capacity 25 mm²
Maximum busbar cross-section 10 mm²
Terminal tightening torque 2.8 N·m

Frequently Asked Questions

What is the ABB S-ARC1 M B6 used for?

The ABB S-ARC1 M B6 is used to protect low-voltage electrical circuits against arc faults, overloads and short circuits in residential, commercial and other building electrical installations.

What is the current rating of the ABB S-ARC1 M B6?

The device has a rated current of 6 A and uses a B tripping characteristic.

What is the breaking capacity of the S-ARC1 M B6?

The ABB S-ARC1 M B6 has a rated short-circuit breaking capacity of 10 kA.

Does the S-ARC1 M B6 include an MCB?

Yes. The S-ARC1 M B6 combines an arc fault detection device (AFDD) with an integrated miniature circuit breaker (MCB), providing arc fault detection together with overload and short-circuit protection.

How is the ABB S-ARC1 M B6 installed?

The device is designed for DIN rail mounting and occupies two modules, with an overall width of 35 mm. The supply can be connected from either the top or bottom.

Trusted Electrical Protection from ABB

ABB S-ARC1 M arc fault detection devices combine advanced arc fault monitoring with proven miniature circuit breaker technology, providing compact protection against arc faults, overloads and short circuits in modern low-voltage electrical installations.