S-ARC1 C25 Arc Fault Detection Device (AFDD) with MCB - 1P+N - C - 25 A - 6 kA

S-ARC1 C25 Arc Fault Detection Device (AFDD) with MCB – 1P+N – C – 25 A – 6 kA

ABB S-ARC1 C25 (2CSA255901R9254) arc fault detection device with integrated MCB: 1P+N, C curve, 25 A, 6 kA breaking capacity.

SKU: S-ARC1 C25Alt SKU: 2CSA255901R9254MPN: 2CSA255901R9254
Price
List Price £212.59 ex VAT
Your Price (ex VAT) Save 30%
£148.81 30% OFF
You save £63.78 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £148.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£148.81

Why Choose the ABB S-ARC1 C25 Arc Fault Detection Device?

The ABB S-ARC1 C25 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.

The S-ARC1 protects end-user circuits against earth, parallel and series arc faults as well as conventional overloads and short-circuit currents. By detecting potentially hazardous electrical arcing that conventional MCB protection alone may not identify, the device provides an additional level of protection against faults associated with damaged conductors, deteriorated insulation and poor electrical connections.

With a rated current of 25 A, a C tripping characteristic and a 6 kA rated service short-circuit breaking capacity, the S-ARC1 C25 is designed for 1P+N single-phase circuits. Its C characteristic makes it suitable for compatible loads with moderate starting or inrush currents, while its compact construction supports space-efficient installation in residential and commercial distribution boards.

Key Advantages

  • Combines arc fault detection and MCB protection in one compact device.
  • 25 A rated current with C tripping characteristic.
  • Protects against earth, parallel and series arc faults.
  • Integrated thermal-magnetic protection against overloads and short circuits.
  • 6 kA rated service short-circuit breaking capacity.
  • 7.5 kA rated ultimate short-circuit breaking capacity.
  • 1P+N configuration for single-phase final circuits.
  • High electrical and mechanical endurance supports dependable operation.
  • Compact two-module design helps conserve distribution board space.

Key Features

  • ABB S-ARC1 arc fault detection device series.
  • 25 A rated current.
  • C tripping characteristic.
  • 1P+N configuration with one protected pole.
  • 6 kA rated service short-circuit breaking capacity.
  • 7.5 kA rated ultimate short-circuit breaking capacity.
  • Detection of earth arc faults.
  • Detection of parallel arc faults.
  • Detection of series arc faults.
  • Integrated thermal-magnetic MCB functionality.
  • 2.5 kV dielectric test voltage.
  • Energy limiting class 3.
  • Electrical endurance of 10,000 cycles.
  • Mechanical endurance of 20,000 cycles.
  • Red ON / green OFF contact position indication.
  • DIN rail mounting with screw terminals.
  • Compact two-module construction.

Enhanced Arc Fault and Overcurrent Protection

Arc fault detection devices monitor electrical circuits for characteristics associated with potentially dangerous electrical arcing. The ABB S-ARC1 is designed to protect single-phase circuits against earth, parallel and series arc faults, while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.

Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. The C tripping characteristic of the S-ARC1 C25 also makes it suitable for compatible circuits where moderate starting or inrush currents may occur.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial electrical distribution systems.
  • Single-phase final circuits requiring enhanced arc fault protection.
  • Circuits protected at 25 A requiring a C tripping characteristic.
  • Compatible electrical loads with moderate starting or inrush currents.
  • Installations where enhanced protection against electrically initiated fires is required.
  • Installations requiring combined arc fault, overload and short-circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type AFDD
Poles 1-pole + N
Current 25 A
Trip Curve C curve
Breaking Capacity 6 kA
Phase Single Phase
Manufacturer ABB
Series S-ARC1
Model S-ARC1 C25
Order code / MPN 2CSA255901R9254
EAN 8012542374114
Product type Arc fault detection device with integrated MCB
Rated current 25 A
Tripping characteristic C
Number of poles 1P+N
Number of protected poles 1
Rated service short-circuit breaking capacity (Ics) 6 kA
Rated ultimate short-circuit breaking capacity (Icu) 7.5 kA
Dielectric test voltage 2.5 kV
Energy limiting class 3
Electrical endurance 10,000 cycles
Mechanical endurance 20,000 cycles
Contact position indication Red ON / green OFF
Power supply connection Arbitrary
Neutral terminal position Right
Actuator type Toggle, orange RAL 2004, sealable in ON/OFF positions
Mounting type DIN rail
Terminal type Screw terminals
Tightening torque 2.8 N·m
Modular width 2 modules
Weight 180 g
Standards IEC/EN 62606, IEC/EN 60898-1

Frequently Asked Questions

What is the ABB S-ARC1 C25 used for?

The ABB S-ARC1 C25 is used to protect compatible single-phase final circuits against earth, parallel and series arc faults, overloads and short circuits using an integrated AFDD and miniature circuit breaker.

What is the current rating of the ABB S-ARC1 C25?

The S-ARC1 C25 has a rated current of 25 A and uses a C tripping characteristic, making it suitable for compatible circuits that can experience moderate starting or inrush currents.

Does the ABB S-ARC1 C25 include residual current protection?

No. The S-ARC1 C25 combines an arc fault detection device with an MCB. Where residual current protection is required, suitable additional residual current protection must be provided in accordance with the applicable electrical installation requirements.

How many poles does the ABB S-ARC1 C25 have?

The ABB S-ARC1 C25 uses a 1P+N configuration with one protected pole for single-phase final circuits.

What is the breaking capacity of the ABB S-ARC1 C25?

The S-ARC1 C25 has a 6 kA rated service short-circuit breaking capacity (Ics) and a 7.5 kA rated ultimate short-circuit breaking capacity (Icu).

Trusted ABB S-ARC1 Arc Fault Protection

ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, providing enhanced protection against electrical arcing, overloads and short circuits in residential and commercial installations.