S-ARC1 C10 Arc Fault Detection Device (AFDD) with MCB - 1P+N - C - 10 A - 6 kA

S-ARC1 C10 Arc Fault Detection Device (AFDD) with MCB – 1P+N – C – 10 A – 6 kA

ABB S-ARC1 C10 (2CSA255901R9104) arc fault detection device with integrated MCB: 1P+N, C curve, 10 A, 6 kA breaking capacity.

SKU: S-ARC1 C10Alt SKU: 2CSA255901R9104MPN: 2CSA255901R9104
Price
List Price £202.48 ex VAT
Your Price (ex VAT) Save 30%
£141.74 30% OFF
You save £60.74 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £141.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£141.74

Why Choose the ABB S-ARC1 C10 Arc Fault Detection Device?

The ABB S-ARC1 C10 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.

The S-ARC1 is designed to protect electrical circuits against potentially hazardous arc faults while its integrated MCB provides conventional protection against overloads and short circuits. Combining these functions in one device helps provide enhanced circuit protection without requiring separate AFDD and MCB modules.

With a rated current of 10 A, a C tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 C10 is designed for 1P+N single-phase circuits. It provides a 6 kA rated service short-circuit breaking capacity and a 7.5 kA rated ultimate short-circuit breaking capacity, making it suitable for compatible residential and commercial final circuits.

Key Advantages

  • Combines arc fault detection and MCB protection in one compact device.
  • 10 A rated current with C tripping characteristic.
  • Provides enhanced protection against potentially hazardous electrical arc faults.
  • Integrated thermal-magnetic protection against overloads and short circuits.
  • 6 kA rated service short-circuit breaking capacity.
  • 7.5 kA rated ultimate short-circuit breaking capacity.
  • 1P+N configuration for single-phase final circuits.
  • Clear red ON / green OFF contact position indication.
  • Compact two-module design helps conserve distribution board space.

Key Features

  • ABB S-ARC1 arc fault detection device series.
  • 10 A rated current.
  • C tripping characteristic.
  • 1P+N configuration with one protected pole.
  • 230–240 V AC rated operational voltage.
  • 50–60 Hz rated frequency.
  • 6 kA rated service short-circuit breaking capacity.
  • 7.5 kA rated ultimate short-circuit breaking capacity.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Integrated thermal-magnetic MCB functionality.
  • 2 W power loss.
  • Red ON / green OFF contact position indication.
  • Operating temperature range from -25 to +55 °C.
  • DIN rail mounting with screw terminals.
  • IP20 terminal / IP40 housing protection ratings.
  • Compact two-module construction.

Enhanced Arc Fault and Overcurrent Protection

Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. When an arc fault is identified, the ABB S-ARC1 can disconnect the affected circuit, while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.

Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. The C tripping characteristic also makes the S-ARC1 C10 suitable for compatible circuits where moderate starting or inrush currents may occur.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial electrical distribution systems.
  • Single-phase final circuits requiring enhanced arc fault protection.
  • Circuits protected at 10 A requiring a C tripping characteristic.
  • Lighting and compatible electrical circuits with moderate inrush currents.
  • Installations where enhanced protection against electrically initiated fires is required.
  • Installations requiring combined arc fault, overload and short-circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type AFDD
Poles 1-pole + N
Current 10 A
Trip Curve C curve
Breaking Capacity 6 kA
Phase Single Phase
Manufacturer ABB
Series S-ARC1
Model S-ARC1 C10
Order code / MPN 2CSA255901R9104
EAN 8012542749837
Product type Arc fault detection device with integrated MCB
Rated current 10 A
Tripping characteristic C
Rated operational voltage 230–240 V AC
Rated frequency 50–60 Hz
Number of poles 1P+N
Number of protected poles 1
Rated service short-circuit breaking capacity (Ics) 6 kA
Rated ultimate short-circuit breaking capacity (Icu) 7.5 kA
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 4 kV
Power loss 2 W
Internal consumption 0.5 W
Voltage drop 203 mV
Internal resistance 20.3 mΩ
Protection rating IP20 terminals / IP40 housing
Pollution degree 2
Operating temperature -25 to +55 °C
Contact position indication Red ON / green OFF
Actuator type Toggle, orange RAL 2004, sealable in ON/OFF positions
Mounting type DIN rail
Terminal type Screw terminals
Tightening torque 2.8 N·m
Modular width 2 modules
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight 180 g
Standards IEC/EN 62606, IEC/EN 60898-1

Frequently Asked Questions

What is the ABB S-ARC1 C10 used for?

The ABB S-ARC1 C10 is used to provide arc fault, overload and short-circuit protection for compatible single-phase final circuits using an integrated AFDD and miniature circuit breaker.

What is the current rating of the ABB S-ARC1 C10?

The S-ARC1 C10 has a rated current of 10 A and uses a C tripping characteristic, making it suitable for compatible circuits that can experience moderate starting or inrush currents.

Does the ABB S-ARC1 C10 include residual current protection?

No. The S-ARC1 C10 combines an arc fault detection device with an MCB. Where residual current protection is required, suitable additional residual current protection must be provided in accordance with the applicable electrical installation requirements.

What supply voltage is the ABB S-ARC1 C10 designed for?

The S-ARC1 C10 has a rated operational voltage of 230–240 V AC, a rated frequency of 50–60 Hz and a 1P+N configuration for single-phase electrical circuits.

What is the breaking capacity of the ABB S-ARC1 C10?

The S-ARC1 C10 has a 6 kA rated service short-circuit breaking capacity (Ics) and a 7.5 kA rated ultimate short-circuit breaking capacity (Icu).

Trusted ABB S-ARC1 Arc Fault Protection

ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, providing enhanced protection against electrical arcing, overloads and short circuits in residential and commercial installations.