ABB S-ARC1 B6 (2CSA255901R9065) arc fault detection device with integrated MCB: 1P+N, B curve, 6 A, 6 kA breaking capacity.
£141.74
The ABB S-ARC1 B6 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 is designed to protect end-user circuits against earth, parallel and series arc faults as well as conventional overloads and short-circuit currents. Integrated AFDD indication and internal testing functionality assist with monitoring the device while providing an additional level of protection against electrical arcing that a conventional MCB alone is not designed to detect.
With a rated current of 6 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 B6 is designed for 1P+N single-phase circuits. It provides a 6 kA rated service short-circuit breaking capacity and a 7.5 kA rated ultimate short-circuit breaking capacity, making it suitable for compatible residential and commercial final circuits.
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. The ABB S-ARC1 is designed to protect against earth, parallel and series arc faults while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.
Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. The S-ARC1 series also incorporates AFDD indication and internal testing functionality to support dependable protection and straightforward fault diagnosis.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 6 A | |
| Trip Curve | B curve | |
| Breaking Capacity | 6 kA | |
| Phase | Single Phase | |
| Manufacturer | ABB | |
| Series | S-ARC1 | |
| Model | S-ARC1 B6 | |
| Order code / MPN | 2CSA255901R9065 | |
| EAN | 8012542750130 | |
| Product type | Arc fault detection device with integrated MCB | |
| Rated current | 6 A | |
| Tripping characteristic | B | |
| Rated operational voltage | 230–240 V AC | |
| Minimum operating voltage | 170 V AC | |
| Rated frequency | 50–60 Hz | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Rated service short-circuit breaking capacity (Ics) | 6 kA | |
| Rated ultimate short-circuit breaking capacity (Icu) | 7.5 kA | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 4 kV | |
| Overvoltage protection threshold | 275 V AC | |
| Power loss | 2.3 W | |
| Protection rating | IP20 terminals / IP40 housing | |
| Pollution degree | 2 | |
| Operating temperature | -25 to +55 °C | |
| Storage temperature | -40 to +70 °C | |
| Contact position indication | Red ON / green OFF | |
| Actuator type | Toggle, orange RAL 2004, sealable in ON/OFF positions | |
| Busbar connection capacity | Up to 10 mm² | |
| Conductor capacity | Up to 25 mm² | |
| Mounting type | DIN rail | |
| Mounting position | Any | |
| Supply side | Either side | |
| Terminal type | Screw terminals | |
| Tightening torque | 2.8 N·m | |
| Modular width | 2 modules | |
| Dimensions (H × W × D) | 85 × 35 × 69 mm | |
| Weight | 180 g | |
| Standards | IEC/EN 62606, IEC/EN 60898-1 |
The ABB S-ARC1 B6 is used to protect single-phase final circuits against earth, parallel and series arc faults, overloads and short circuits using an integrated AFDD and miniature circuit breaker.
The S-ARC1 B6 has a rated current of 6 A and uses a B tripping characteristic, making it suitable for compatible low-current circuits with relatively low starting or inrush currents.
No. The S-ARC1 B6 combines an arc fault detection device with an MCB. Where residual current protection is required, suitable additional residual current protection must be provided in accordance with the applicable electrical installation requirements.
The S-ARC1 B6 has a rated operational voltage of 230–240 V AC, a rated frequency of 50–60 Hz and is designed for 1P+N single-phase electrical circuits.
The S-ARC1 B6 has a 6 kA rated service short-circuit breaking capacity and a 7.5 kA rated ultimate short-circuit breaking capacity.
ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, providing enhanced protection against electrical arcing, overloads and short circuits in residential and commercial installations.