Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S-ARC1 B32 (2CSA255901R9325) arc fault detection device with integrated MCB: 1P+N, B curve, 32 A, 6 kA breaking capacity.
£156.24
The ABB S-ARC1 B32 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 protects end-user circuits against earth, parallel and series arc faults as well as conventional overloads and short-circuit currents. By detecting potentially hazardous electrical arcing that conventional MCB protection alone may not identify, it provides an additional level of circuit protection for residential and commercial electrical installations.
With a rated current of 32 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 B32 is designed for 1P+N single-phase circuits. Its 6 kA short-circuit breaking capacity and compact two-module construction make it suitable for final circuits requiring combined arc fault, overload and short-circuit protection.
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. The ABB S-ARC1 is designed to protect against earth, parallel and series arc faults while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.
Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. The S-ARC1 range is designed for residential and commercial applications where enhanced protection of single-phase final circuits is required.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 32 A | |
| Trip Curve | B curve | |
| Breaking Capacity | 6 kA | |
| Phase | Single Phase | |
| Manufacturer | ABB | |
| Series | S-ARC1 | |
| Model | S-ARC1 B32 | |
| Order code / MPN | 2CSA255901R9325 | |
| EAN | 8012542341017 | |
| Product type | Arc fault detection device with integrated MCB | |
| Rated current | 32 A | |
| Tripping characteristic | B | |
| Rated operational voltage | 230–240 V AC | |
| Input voltage type | AC | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Short-circuit breaking capacity | 6 kA | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 4 kV | |
| Mechanical endurance | 20,000 cycles | |
| Operating temperature | -25 to +55 °C | |
| Protection rating | IP40 housing | |
| Tripping mechanism | Thermal-magnetic | |
| Actuator type | Toggle, orange RAL 2004, sealable in ON/OFF positions | |
| Busbar connection capacity | 10 mm² | |
| Rigid conductor capacity | 1–25 mm² | |
| Flexible conductor capacity | 1–16 mm² | |
| Wire stripping length | 12 mm | |
| Mounting type | DIN rail | |
| Terminal type | Screw terminals | |
| Tightening torque | 2.8 N·m | |
| Modular width | 2 modules | |
| Dimensions (H × W × D) | 85 × 35 × 69 mm | |
| Weight | 180 g | |
| Standards | IEC/EN 62606, IEC/EN 60898-1 |
The ABB S-ARC1 B32 is used to protect single-phase final circuits against earth, parallel and series arc faults, overloads and short circuits using an integrated AFDD and miniature circuit breaker.
The S-ARC1 B32 has a rated current of 32 A and uses a B tripping characteristic, making it suitable for compatible circuits with relatively low starting or inrush currents.
No. The S-ARC1 B32 combines an arc fault detection device with an MCB. Where residual current protection is required, suitable additional residual current protection must be provided in accordance with the applicable electrical installation requirements.
The S-ARC1 B32 has a rated operational voltage of 230–240 V AC and is designed for 1P+N single-phase electrical circuits.
The ABB S-ARC1 B32 has a 6 kA short-circuit breaking capacity, providing thermal-magnetic overcurrent protection alongside its arc fault detection functionality.
ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, providing enhanced protection against electrical arcing, overloads and short circuits in residential and commercial installations.