S-ARC1 B16 Arc Fault Detection Device (AFDD) with MCB - 1P+N - B - 16 A - 6 kA

S-ARC1 B16 Arc Fault Detection Device (AFDD) with MCB – 1P+N – B – 16 A – 6 kA

ABB S-ARC1 B16 (2CSA255901R9165) arc fault detection device with integrated MCB: 1P+N, B curve, 16 A, 6 kA breaking capacity.

SKU: S-ARC1 B16Alt SKU: 2CSA255901R9165MPN: 2CSA255901R9165
Price
List Price £202.48 ex VAT
Your Price (ex VAT) Save 30%
£141.74 30% OFF
You save £60.74 per unit
Manufacturer Lead Time Estimated Delivery 9 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £141.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£141.74

Why Choose the ABB S-ARC1 B16 Arc Fault Detection Device?

The ABB S-ARC1 B16 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.

The S-ARC1 detects potentially dangerous arc faults and disconnects the affected circuit, helping reduce the risk of electrical fires caused by damaged wiring, loose connections and other arcing conditions. Its integrated MCB provides conventional protection against overloads and short circuits, while an AFDD test button, continuous internal self-test and LED troubleshooting indication help simplify verification and fault diagnosis.

With a rated current of 16 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 B16 is designed for 1P+N single-phase circuits. Its 6 kA breaking capacity and compact construction make it suitable for residential and commercial final circuits requiring combined arc fault, overload and short-circuit protection.

Key Advantages

  • Combines arc fault detection and MCB protection in one compact device.
  • 16 A rated current with B tripping characteristic.
  • Detects potentially dangerous arc faults and automatically disconnects the affected circuit.
  • Integrated thermal-magnetic protection against overloads and short circuits.
  • 6 kA short-circuit breaking capacity.
  • Continuous internal self-test monitors the arc detection circuit.
  • LED troubleshooting indication assists with identifying the cause of a trip.
  • Contact position indication provides clear open or closed contact status.
  • Compact two-module design helps conserve distribution board space.

Key Features

  • ABB S-ARC1 arc fault detection device series.
  • 16 A rated current.
  • B tripping characteristic.
  • 1P+N configuration.
  • 230–240 V AC rated operational voltage.
  • 6 kA breaking capacity.
  • Integrated thermal-magnetic MCB functionality.
  • Orange AFDD test pushbutton for functional verification.
  • Continuous internal self-test of the arc detection circuit.
  • LED troubleshooting indicator with trip-cause indication.
  • Contact position indicator with red closed and green open indication.
  • DIN rail mounting with screw terminals.
  • IP20 / IP40 protection ratings.
  • Compact two-module construction.
  • Complies with IEC/EN 62606 and IEC/EN 60898-1.

Enhanced Arc Fault and Overcurrent Protection

Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. When an arc fault is detected, the ABB S-ARC1 disconnects the affected circuit, helping reduce the risk of electrical fires while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short circuits.

Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. Continuous internal self-testing, LED troubleshooting indication and a dedicated AFDD test button further support reliable operation and straightforward maintenance.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial electrical distribution systems.
  • Single-phase final circuits requiring arc fault protection.
  • Circuits protected at 16 A requiring a B tripping characteristic.
  • Socket, lighting and compatible general-purpose final circuits.
  • Buildings containing valuable or difficult-to-replace equipment and materials.
  • Installations requiring combined arc fault, overload and short-circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type AFDD
Poles 1-pole + N
Current 16 A
Trip Curve B curve
Breaking Capacity 6 kA
Phase Single Phase
Manufacturer ABB
Series S-ARC1
Model S-ARC1 B16
Order code / MPN 2CSA255901R9165
EAN 8012542178033
Product type Arc fault detection device with integrated MCB
Rated current 16 A
Tripping characteristic B
Rated operational voltage 230–240 V AC
Number of poles 1P+N
Breaking capacity 6 kA
Protection rating IP20 / IP40
Tripping mechanism Thermal-magnetic
Mounting type DIN rail
Terminal type Screw terminals
Reset actuator type Toggle switch
Modular width 2 modules
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight 180 g
Standards IEC/EN 62606, IEC/EN 60898-1

Frequently Asked Questions

What is the ABB S-ARC1 B16 used for?

The ABB S-ARC1 B16 is used to protect single-phase final circuits against potentially dangerous arc faults, overloads and short circuits using an integrated AFDD and miniature circuit breaker.

What is the current rating of the ABB S-ARC1 B16?

The S-ARC1 B16 has a rated current of 16 A and uses a B tripping characteristic, making it suitable for compatible circuits with relatively low starting or inrush currents.

Does the ABB S-ARC1 B16 include residual current protection?

No. The S-ARC1 B16 combines an arc fault detection device with an MCB. Where residual current protection is required, it can be combined with suitable upstream residual current protection in accordance with the applicable electrical installation requirements.

What supply voltage is the ABB S-ARC1 B16 designed for?

The S-ARC1 B16 has a rated operational voltage of 230–240 V AC and is designed for 1P+N single-phase electrical circuits.

What is the breaking capacity of the ABB S-ARC1 B16?

The ABB S-ARC1 B16 has a 6 kA short-circuit breaking capacity, providing integrated overcurrent protection alongside its arc fault detection functionality.

Trusted ABB Arc Fault Protection

ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, helping protect people, buildings and valuable property against electrical arcing, overloads and short circuits.