Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S-ARC1 B16 (2CSA255901R9165) arc fault detection device with integrated MCB: 1P+N, B curve, 16 A, 6 kA breaking capacity.
£141.74
The ABB S-ARC1 B16 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 detects potentially dangerous arc faults and disconnects the affected circuit, helping reduce the risk of electrical fires caused by damaged wiring, loose connections and other arcing conditions. Its integrated MCB provides conventional protection against overloads and short circuits, while an AFDD test button, continuous internal self-test and LED troubleshooting indication help simplify verification and fault diagnosis.
With a rated current of 16 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 B16 is designed for 1P+N single-phase circuits. Its 6 kA breaking capacity and compact construction make it suitable for residential and commercial final circuits requiring combined arc fault, overload and short-circuit protection.
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. When an arc fault is detected, the ABB S-ARC1 disconnects the affected circuit, helping reduce the risk of electrical fires while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short circuits.
Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. Continuous internal self-testing, LED troubleshooting indication and a dedicated AFDD test button further support reliable operation and straightforward maintenance.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 16 A | |
| Trip Curve | B curve | |
| Breaking Capacity | 6 kA | |
| Phase | Single Phase | |
| Manufacturer | ABB | |
| Series | S-ARC1 | |
| Model | S-ARC1 B16 | |
| Order code / MPN | 2CSA255901R9165 | |
| EAN | 8012542178033 | |
| Product type | Arc fault detection device with integrated MCB | |
| Rated current | 16 A | |
| Tripping characteristic | B | |
| Rated operational voltage | 230–240 V AC | |
| Number of poles | 1P+N | |
| Breaking capacity | 6 kA | |
| Protection rating | IP20 / IP40 | |
| Tripping mechanism | Thermal-magnetic | |
| Mounting type | DIN rail | |
| Terminal type | Screw terminals | |
| Reset actuator type | Toggle switch | |
| Modular width | 2 modules | |
| Dimensions (H × W × D) | 85 × 35 × 69 mm | |
| Weight | 180 g | |
| Standards | IEC/EN 62606, IEC/EN 60898-1 |
The ABB S-ARC1 B16 is used to protect single-phase final circuits against potentially dangerous arc faults, overloads and short circuits using an integrated AFDD and miniature circuit breaker.
The S-ARC1 B16 has a rated current of 16 A and uses a B tripping characteristic, making it suitable for compatible circuits with relatively low starting or inrush currents.
No. The S-ARC1 B16 combines an arc fault detection device with an MCB. Where residual current protection is required, it can be combined with suitable upstream residual current protection in accordance with the applicable electrical installation requirements.
The S-ARC1 B16 has a rated operational voltage of 230–240 V AC and is designed for 1P+N single-phase electrical circuits.
The ABB S-ARC1 B16 has a 6 kA short-circuit breaking capacity, providing integrated overcurrent protection alongside its arc fault detection functionality.
ABB S-ARC1 devices combine arc fault detection with thermal-magnetic overcurrent protection in a compact DIN rail format, helping protect people, buildings and valuable property against electrical arcing, overloads and short circuits.