P2MB2PC080 - MINIAT. CIRCUIT BREAKER 2P CURVE C 80A

P2MB2PC080 – MINIAT. CIRCUIT BREAKER 2P CURVE C 80A

Lovato P2MB2PC080 two-pole miniature circuit breaker with 80 A rated current, C tripping curve, 10 kA short-circuit breaking capacity and 230/400 V AC operational voltage.

SKU: P2MB2PC080MPN: P2MB2PC080
Price
List Price £147.79 ex VAT
Your Price (ex VAT) Save 40%
£88.68 40% OFF
You save £59.12 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £88.68
Trade pricing is personalised to your account

Manufacturer Lead Time

£88.68

Why Choose the Lovato P2MB2PC080 Miniature Circuit Breaker?

The Lovato P2MB2PC080 is a robust two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the Lovato Electric P2 MB modular protection range, it provides dependable thermal-magnetic protection for industrial machinery, control panels and higher-current power-distribution systems.

Featuring an 80 A rated current, C tripping curve and 10 kA short-circuit breaking capacity, the P2MB2PC080 is suitable for circuits supplying equipment with moderate inrush currents. The C characteristic accommodates normal starting currents from motors, transformers and other inductive loads while maintaining reliable protection during genuine fault conditions.

The breaker has a 2P configuration, occupies 3 DIN modules and supports operational voltages of 230/400 V AC or up to 125 V DC. Its high-capacity screw terminals, wide operating-temperature range and standard 35 mm DIN rail mounting make it suitable for demanding commercial and industrial electrical installations.

Key Advantages

  • Provides dependable overload and short-circuit protection.
  • 80 A rated current for higher-capacity electrical circuits.
  • Two-pole switching disconnects both protected conductors simultaneously.
  • C tripping curve accommodates moderate equipment starting currents.
  • 10 kA short-circuit breaking capacity for reliable fault interruption.
  • Suitable for both AC and DC circuit protection.

Key Features

  • Lovato Electric P2 MB miniature circuit breaker.
  • Two-pole configuration.
  • 80 A rated current.
  • C curve thermal-magnetic tripping characteristic.
  • 10 kA IEC short-circuit breaking capacity.
  • 230/400 V AC rated operational voltage.
  • Suitable for operation at up to 125 V DC.
  • 4 kV rated impulse withstand voltage.
  • Compact 3-module construction.
  • Standard 35 mm DIN rail mounting.

Reliable Two-Pole Circuit Protection

The Lovato P2MB2PC080 monitors the current flowing through both protected conductors and automatically disconnects the circuit when an overload or short circuit occurs. Its thermal release responds to sustained overcurrent conditions, while the magnetic release provides rapid interruption during severe short-circuit faults.

The C curve characteristic makes this circuit breaker suitable for equipment with moderate inrush currents, including motors, transformers, lighting circuits and industrial control systems. Its linked two-pole mechanism ensures both poles are disconnected together, providing dependable isolation for single-phase and suitable DC circuits.

Typical Applications

  • Industrial control panels and switchboards.
  • Machinery and OEM electrical systems.
  • Commercial power-distribution boards.
  • Single-phase line and neutral protection.
  • Motor and transformer supply circuits.
  • AC and low-voltage DC circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 80 A
Poles 2-pole
Device Type MCB
Trip Curve C curve
Breaking Capacity 10 kA
Manufacturer Lovato Electric
Series P2 MB
Model P2MB2PC080
Product type Miniature circuit breaker
Tripping mechanism Thermal magnetic
Number of poles 2P
Number of protected poles 2
Number of DIN modules 3
Rated current 80 A
Tripping curve C
Short-circuit breaking capacity 10 kA
Rated operational voltage AC 230/400 V AC
Rated operational voltage DC 125 V DC
Voltage type AC / DC
Rated insulation voltage 400 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Electrical life 10,000 cycles
Mechanical life 10,000 cycles
Operating temperature -40 to +70 °C
Storage temperature -40 to +80 °C
Maximum operating altitude 2000 m
Mounting type 35 mm DIN rail
Terminal type Screw terminals
Terminal tightening torque 3.2 to 3.5 Nm
Conductor capacity 2.5 to 50 mm²
Built-in depth approximately 67 mm
Width approximately 54 mm
Protection rating IP20
Pollution degree 3
Overvoltage category IV
EAN 8013975204290
Compliance IEC/EN 60947-2, UL 1077 and CSA C22.2 No. 235
Certifications TÜV Rheinland, cURus and EAC
HS Code 85362090

Frequently Asked Questions

What is the Lovato P2MB2PC080 used for?

The P2MB2PC080 protects two-pole electrical circuits and connected equipment against sustained overloads and short-circuit faults.

What is the rated current of this circuit breaker?

The Lovato P2MB2PC080 has a rated current of 80 A.

What does the C tripping curve mean?

A C curve circuit breaker tolerates moderate temporary inrush currents while still disconnecting the circuit during overload or short-circuit conditions.

What is the breaking capacity of the P2MB2PC080?

The breaker has a rated short-circuit breaking capacity of 10 kA.

Can the P2MB2PC080 be used on DC circuits?

Yes. The circuit breaker is rated for operation at up to 125 V DC, subject to correct circuit design, polarity and installation requirements.

How is the Lovato P2MB2PC080 installed?

The circuit breaker clips onto a standard 35 mm DIN rail and occupies three DIN modules within a suitable electrical enclosure.

Trusted Circuit Protection from Lovato Electric

Lovato Electric miniature circuit breakers are used by electrical contractors, panel builders and industrial engineers to provide dependable protection for machinery, distribution systems and control-panel circuits.