P1RE1NB10A300 Lovato RCBO 1P+N B 10A IDN 300MA 10KA

P1RE1NB10A300 Lovato RCBO 1P+N B 10A IDN 300MA 10KA

Lovato P1RE1NB10A300 is a 10 A 1P+N type A RCBO with a type B overcurrent tripping curve, 300 mA residual-current rating and 10 kA IEC short-circuit breaking capacity.

SKU: P1RE1NB10A300
Price
List Price £150.35 ex VAT
Your Price (ex VAT) Save 40%
£90.21 40% OFF
You save £60.14 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £90.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£90.21

Why Choose the Lovato P1RE1NB10A300 10 A 1P+N RCBO?

The Lovato P1RE1NB10A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) designed to combine residual-current, overload and short-circuit protection in a single modular device. Part of the Lovato P1RE range, it is rated at 10 A with a 10 kA short-circuit breaking capacity.

This model features a type B tripping curve and type A residual-current characteristic, allowing it to detect sinusoidal AC residual currents as well as pulsating DC residual currents. Its rated residual operating current of 300 mA makes it suitable for appropriately designed installations requiring this residual-current threshold.

The P1RE1NB10A300 occupies two DIN modules and mounts on a standard 35 mm DIN rail. The 1P+N configuration switches the phase and neutral conductors, while dedicated indication and operating features help distinguish residual-current operation from overload or short-circuit tripping.

Key Advantages

  • Combines MCB and residual-current protection in one compact RCBO.
  • 10 A rated current with type B overcurrent tripping characteristic.
  • 300 mA rated residual operating current.
  • Type A residual-current detection for AC and pulsating DC residual currents.
  • High 10 kA IEC short-circuit breaking capacity.
  • 1P+N configuration for single-phase circuits with switched neutral.
  • Compact two-module DIN-rail format for distribution boards and control panels.

Key Features

  • Lovato P1RE series RCBO.
  • 1 pole + neutral (1P+N) configuration.
  • 10 A rated current (In).
  • Type B tripping curve.
  • Type A residual-current characteristic.
  • 300 mA rated residual current (IΔn).
  • 10 kA IEC breaking capacity.
  • Two DIN modules wide.
  • Contact-status indication.
  • Separate operating indication to distinguish residual-current tripping from overload or short-circuit tripping.
  • Designed for 35 mm DIN-rail mounting.

Combined Residual-Current and Overcurrent Protection

An RCBO combines the functions normally provided by a miniature circuit breaker and a residual current device. The Lovato P1RE1NB10A300 can disconnect the protected circuit in response to overloads and short circuits while also monitoring for residual current to earth, reducing the number of separate protective devices required within a distribution assembly.

The type B overcurrent curve provides the instantaneous tripping characteristics associated with B-curve circuit protection, while the type A residual-current characteristic responds to both sinusoidal AC and pulsating DC residual currents. Its 300 mA IΔn rating should be selected according to the protection requirements and applicable electrical regulations for the installation.

Typical Applications

  • Single-phase electrical distribution boards.
  • Industrial control panels.
  • Commercial electrical installations.
  • Machinery auxiliary circuits.
  • Building-services distribution systems.
  • Circuits requiring combined overload, short-circuit and residual-current protection.
  • Installations specified for a 300 mA type A RCBO.

Technical Specifications

Tick the specs you need, then view products that match.

Phase Single Phase
Poles 1-pole + N
Device Type RCBO
Trip Curve B curve
Breaking Capacity 10 kA
Residual Current 300 mA
HS Code 85362010
Manufacturer Lovato Electric
Series P1RE
Model / order code P1RE1NB10A300
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 1P+N
Rated current (In) 10 A
Tripping curve B
Residual-current characteristic Type A
Rated residual operating current (IΔn) 300 mA
IEC short-circuit breaking capacity (Icn) 10 kA
Number of DIN modules 2
Mounting 35 mm DIN rail
Protection functions Residual current, overload and short circuit
Residual-current detection Sinusoidal AC and pulsating DC residual currents
Contact status indication Yes
Compliance IEC

Frequently Asked Questions

What is the Lovato P1RE1NB10A300?

The P1RE1NB10A300 is a 1P+N RCBO combining residual-current protection with overload and short-circuit protection in a two-module DIN-rail device.

What is the rated current of the P1RE1NB10A300?

The Lovato P1RE1NB10A300 has a rated current of 10 A.

What residual-current sensitivity does the P1RE1NB10A300 have?

The RCBO has a rated residual operating current of 300 mA.

Is the P1RE1NB10A300 a type A RCBO?

Yes. The P1RE1NB10A300 has a type A residual-current characteristic, designed to respond to sinusoidal AC residual currents and pulsating DC residual currents.

What tripping curve does the P1RE1NB10A300 use?

The P1RE1NB10A300 uses a type B overcurrent tripping curve.

What is the short-circuit breaking capacity of the P1RE1NB10A300?

The P1RE1NB10A300 has an IEC short-circuit breaking capacity of 10 kA.

How much DIN-rail space does the P1RE1NB10A300 require?

The device occupies two DIN modules and is designed for mounting on a standard 35 mm DIN rail.

Trusted Protection for Electrical Distribution Systems