Lovato P1RD2P63A300 is a 2-pole 63 A Type A residual current circuit breaker with 300 mA sensitivity, a 230 V AC operational rating and a 10 kA conditional short-circuit current rating for residual current protection.
£165.47
The Lovato P1RD2P63A300 is a 2-pole residual current circuit breaker (RCCB) designed to provide reliable residual current protection in electrical installations. As part of the Lovato P1RD series, it combines a compact two-module format with IEC compliance, making it suitable for distribution boards, industrial control panels and electrical systems requiring dependable earth leakage protection.
Rated at 63 A with a rated residual operating current of 300 mA, the P1RD2P63A300 uses a Type A residual operating characteristic. This enables detection of sinusoidal alternating residual currents and pulsating DC residual currents, making Type A protection particularly useful for circuits containing electronic equipment capable of producing pulsating residual current waveforms.
The P1RD2P63A300 operates at 230 V AC and 50/60 Hz, with a 10 kA short-circuit rating and 10 kA rated conditional short-circuit current. Its two-pole, two-module construction mounts directly onto a standard 35 mm DIN rail, providing straightforward integration into electrical distribution equipment, machinery and control cabinets.
Residual current circuit breakers such as the Lovato P1RD2P63A300 monitor the balance of current flowing through the conductors of an electrical circuit and disconnect the supply when residual current exceeds the specified threshold. This provides an important protective measure against earth leakage faults and helps reduce risks associated with insulation failure and unintended leakage currents.
The Type A characteristic provides protection for sinusoidal alternating residual currents as well as pulsating DC residual currents that may be generated by electronic equipment. With its 300 mA sensitivity, 63 A current rating and two-pole configuration, the P1RD2P63A300 is suited to appropriately designed installations requiring Type A residual current protection. As an RCCB, it should be coordinated with suitable overcurrent and short-circuit protection according to the requirements of the installation.
Tick the specs you need, then view products that match.
| Poles | 2-pole | |
|---|---|---|
| Device Type | RCD | |
| Residual Current | 300 mA | |
| RCD Type | Type A | |
| Manufacturer | Lovato Electric | |
| Series | P1RD | |
| Model | P1RD2P63A300 | |
| Product type | Residual current circuit breaker (RCCB) | |
| Number of poles | 2P | |
| Number of DIN modules | 2 | |
| Rated current In | 63 A | |
| Residual operation characteristic | Type A | |
| Rated residual current IΔn | 300 mA | |
| Rated operational voltage | 230 V AC | |
| Rated insulation voltage Ui | 400 V | |
| Rated impulse withstand voltage Uimp | 4 kV | |
| Rated frequency | 50/60 Hz | |
| Short-circuit rating (IEC) | 10 kA | |
| Rated conditional short-circuit current Inc | 10 kA | |
| Compliance | IEC | |
| Electrical life | 10,000 cycles | |
| Mechanical life | 20,000 cycles | |
| Operating temperature | -35 to +70 °C | |
| Storage temperature | -40 to +80 °C | |
| Maximum altitude | 2,000 m | |
| Operating position | Vertical plane | |
| Mounting type | 35 mm DIN rail | |
| Maximum terminal tightening torque | 2 Nm | |
| Terminal tool | PZ2 | |
| IEC conductor cross-section | 2.5–35 mm² | |
| Conductor size | AWG 14 to 2 | |
| Weight | 185 g | |
| Frontal protection rating | IP20 | |
| Pollution degree | 2 | |
| EAN | 8013975269299 | |
| HS code | 85363030 |
The P1RD2P63A300 is a 2-pole residual current circuit breaker designed to detect residual current and disconnect the electrical supply when leakage exceeds its specified 300 mA operating threshold.
The Lovato P1RD2P63A300 has a rated current of 63 A and a rated residual operating current of 300 mA.
Type A means the RCCB is designed to respond to both sinusoidal alternating residual currents and pulsating DC residual currents. This makes it suitable for appropriately specified circuits where connected electronic equipment may produce pulsating residual current waveforms.
The P1RD2P63A300 has a rated operational voltage of 230 V AC, a rated insulation voltage of 400 V and a rated frequency of 50/60 Hz.
The RCCB occupies two DIN modules and is designed for mounting onto a standard 35 mm DIN rail. As an RCCB, it should be coordinated with suitable overcurrent and short-circuit protection according to the requirements of the electrical installation.
Lovato Electric P1RD residual current circuit breakers provide dependable earth leakage protection for professional electrical distribution systems, combining Type A residual current detection, compact DIN rail installation and robust electrical performance for industrial and commercial applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.