P1RB1NC40A030 - RCBO 1P+N CURVE C 40A IDN 30MA TYPE A

P1RB1NC40A030 – RCBO 1P+N CURVE C 40A IDN 30MA TYPE A

Lovato P1RB1NC40A030 1P+N RCBO with 40 A rated current, C tripping curve, 30 mA Type A residual current protection and 10 kA short-circuit rating.

SKU: P1RB1NC40A030MPN: P1RB1NC40A030
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Lovato P1RB1NC40A030 RCBO?

The Lovato P1RB1NC40A030 is a compact residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against earth leakage, overloads and short circuits. Combining residual current and miniature circuit-breaker functions in one device, it provides comprehensive circuit protection while reducing the amount of space required inside a distribution board.

This Lovato Electric RCBO features a 40 A rated current, C tripping curve and 30 mA Type A residual current sensitivity. Type A protection detects sinusoidal alternating residual currents and pulsating DC residual currents, making the unit suitable for modern electrical loads containing electronic components.

With a 1P+N pole configuration, 10 kA short-circuit breaking capacity and compact two-module construction, the P1RB1NC40A030 is suitable for residential, commercial and light-industrial distribution systems. It mounts onto a standard 35 mm DIN rail and complies with IEC/EN 61009-1.

Key Advantages

  • Combines earth leakage, overload and short-circuit protection in one device.
  • 40 A rated current for higher-load final circuits.
  • 30 mA Type A residual current protection for AC and pulsating DC leakage currents.
  • 10 kA short-circuit rating for dependable fault protection.
  • C tripping curve suitable for circuits with moderate inrush currents.
  • Compact two-module DIN rail design helps conserve distribution-board space.

Key Features

  • Lovato Electric P1 RB series RCBO.
  • 1P+N pole configuration.
  • 40 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual current characteristic.
  • C curve overcurrent tripping characteristic.
  • 10 kA short-circuit breaking capacity.
  • 230 V AC rated operational voltage.
  • Standard 35 mm DIN rail mounting.
  • Compliant with IEC/EN 61009-1.

Combined Residual Current and Overcurrent Protection

An RCBO combines the functions of a residual current device and a miniature circuit breaker. The Lovato P1RB1NC40A030 disconnects the protected circuit when it detects dangerous earth leakage, sustained overload conditions or high short-circuit currents.

Its Type A residual current characteristic makes it suitable for equipment containing electronic power supplies, rectifiers and control circuits that may produce pulsating DC leakage. The C curve characteristic also provides reliable circuit protection while tolerating the moderate starting currents associated with many commercial and industrial loads.

Typical Applications

  • Residential consumer units and distribution boards.
  • Commercial lighting and power circuits.
  • Industrial control panels and auxiliary circuits.
  • Socket outlet and appliance circuits.
  • Circuits supplying equipment with electronic power supplies.
  • Heating, ventilation and building-services installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 40 A
Phase Single Phase
Poles 1-pole + N
Device Type RCBO
Trip Curve C curve
Residual Current 30 mA
RCD Type Type A
Manufacturer Lovato Electric
Series P1 RB
Model P1RB1NC40A030
Product type Residual current circuit breaker with overcurrent protection
Protection device type RCBO
Number of poles 1P+N
Number of DIN modules 2
Rated current 40 A
Tripping curve C
Residual current type Type A
Rated residual current 30 mA
Short-circuit rating 10 kA
Rated operational voltage 230 V AC
Rated insulation voltage 400 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Maximum power dissipation per pole 4 W
Operating temperature -35 to +70 °C
Storage temperature -40 to +80 °C
Maximum operating altitude 2000 m
Mounting type 35 mm DIN rail
Terminal tightening torque 1.8–2 Nm
Conductor capacity 1–25 mm²
Front protection rating IP20
Pollution degree 2
Dimensions (H × W × D) approximately 82 × 36 × 60 mm
Weight approximately 205 g
Compliance IEC/EN 61009-1
Certifications TÜV Rheinland, EAC

Frequently Asked Questions

What is the Lovato P1RB1NC40A030 used for?

The P1RB1NC40A030 protects a single-phase electrical circuit against earth leakage, overloads and short circuits by combining RCD and MCB functions in one RCBO.

What is the current rating of this RCBO?

The Lovato P1RB1NC40A030 has a rated current of 40 A and uses a C tripping curve.

What residual current sensitivity does it provide?

This RCBO has a rated residual operating current of 30 mA, providing additional protection against electric shock and earth leakage faults.

What does Type A residual current protection mean?

Type A protection detects sinusoidal alternating residual currents and pulsating DC residual currents, making it suitable for circuits supplying many modern electronic devices.

What is the breaking capacity of the P1RB1NC40A030?

The device has a rated short-circuit breaking capacity of 10 kA in accordance with IEC requirements.

How is this Lovato RCBO installed?

The P1RB1NC40A030 occupies two DIN modules and clips onto a standard 35 mm DIN rail inside a suitable distribution board or control panel.

Trusted Circuit Protection from Lovato Electric

Lovato Electric protection devices are used in residential, commercial and industrial electrical systems to provide dependable circuit protection, straightforward installation and compliance with recognised international standards.