P1RB1NC10AC300 - RCBO 1P+N CURVE C 10A IDN 300MA TYPE AC

P1RB1NC10AC300 – RCBO 1P+N CURVE C 10A IDN 300MA TYPE AC

Lovato P1RB1NC10AC300 residual current circuit breaker with overcurrent protection, featuring a 1P+N configuration, 10 A rated current, C tripping characteristic, Type AC 300 mA residual current protection and 10 kA breaking capacity.

SKU: P1RB1NC10AC300MPN: P1RB1NC10AC300
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Lovato P1RB1NC10AC300 RCBO?

The Lovato P1RB1NC10AC300 is a compact and dependable residual current circuit breaker with overcurrent protection (RCBO) designed to protect electrical circuits against overloads, short circuits and earth leakage faults. As part of the Lovato Electric P1RB series, it combines miniature circuit breaker and residual current protection within a single modular device.

This RCBO features a 1P+N pole configuration, allowing the phase conductor to be switched and protected while the neutral conductor is simultaneously isolated. Its combined design helps simplify distribution board layouts, reduce installation time and conserve valuable DIN rail space compared with installing separate protective devices.

With a rated current of 10 A, a C tripping characteristic, Type AC residual current detection and a rated residual operating current of 300 mA, the P1RB1NC10AC300 is suitable for circuit and equipment protection in commercial and industrial installations. Its 10 kA breaking capacity provides robust performance where higher prospective fault currents may be present.

Key Advantages

  • Combined protection against overloads, short circuits and earth leakage faults.
  • 10 A rated current for lower-current electrical circuits.
  • C tripping characteristic suitable for loads with moderate starting currents.
  • Type AC residual current detection for sinusoidal alternating leakage currents.
  • 300 mA residual operating current for equipment and fire-risk protection applications.
  • 10 kA breaking capacity for reliable fault interruption.
  • Compact two-module DIN rail design.

Key Features

  • Lovato Electric P1RB series.
  • Residual current circuit breaker with overcurrent protection.
  • 1P+N pole configuration.
  • 10 A rated current.
  • C curve overcurrent characteristic.
  • Type AC residual current characteristic.
  • 300 mA rated residual operating current.
  • 10 kA short-circuit breaking capacity.
  • Compact two-module construction.
  • Compliant with IEC/EN 61009-1.

Reliable Combined Circuit Protection

An RCBO combines the functions of an overcurrent circuit breaker and a residual current protective device. The Lovato P1RB1NC10AC300 disconnects the protected circuit when it detects an overload, short circuit or qualifying earth leakage fault, helping prevent damage to wiring and connected equipment.

The 300 mA residual current rating is generally intended for equipment protection, installation monitoring and reducing risks associated with insulation faults. It is not normally selected as a substitute for a 30 mA device where additional personal protection is required.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial power distribution systems.
  • Machinery and automation control panels.
  • Equipment feeder circuits.
  • Lighting and general power circuits.
  • Circuits requiring combined overcurrent and earth leakage protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 10 A
Phase Single Phase
Poles 1-pole + N
Device Type RCBO
Trip Curve C curve
Breaking Capacity 10 kA
Residual Current 300 mA
RCD Type Type AC
Manufacturer Lovato Electric
Series P1RB
Model P1RB1NC10AC300
Product type Residual current circuit breaker with overcurrent protection
Abbreviation RCBO
Pole configuration 1P+N
Rated current 10 A
Tripping characteristic C curve
Residual current type Type AC
Rated residual operating current 300 mA
Short-circuit breaking capacity 10 kA
Number of DIN modules 2
Mounting type DIN rail mounting
Applicable standard IEC/EN 61009-1
Certifications TÜV Rheinland and EAC

Frequently Asked Questions

What is the Lovato P1RB1NC10AC300 used for?

The P1RB1NC10AC300 provides combined protection against overloads, short circuits and AC earth leakage faults in electrical distribution and control systems.

What is the rated current of this RCBO?

The device has a rated current of 10 A and uses a C tripping characteristic.

What residual current sensitivity does it provide?

The P1RB1NC10AC300 has a rated residual operating current of 300 mA.

What does Type AC mean?

Type AC means the RCBO is designed to detect sinusoidal alternating residual currents. It should be selected only where this residual current characteristic is appropriate for the connected loads.

What is the breaking capacity of the P1RB1NC10AC300?

The RCBO has a rated short-circuit breaking capacity of 10 kA.

How much DIN rail space does this RCBO require?

The P1RB1NC10AC300 occupies two DIN modules and has a 1P+N configuration.

Trusted by Electrical Professionals

Lovato Electric circuit protection products are used by electrical engineers, panel builders and installation professionals seeking dependable performance, straightforward installation and effective protection for commercial and industrial systems.