P1MBUH2PC25 - MINIATURE CIRCUIT BREAKER 2P CURVE C 25A UL489

P1MBUH2PC25 – MINIATURE CIRCUIT BREAKER 2P CURVE C 25A UL489

Lovato P1MBUH2PC25 two-pole miniature circuit breaker with a 25 A rating, Type C tripping characteristic, 10 kA breaking capacity and compact two-module DIN rail design.

SKU: P1MBUH2PC25MPN: P1MBUH2PC25
Price
List Price £124.22 ex VAT
Your Price (ex VAT) Save 40%
£74.53 40% OFF
You save £49.69 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £74.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£74.53

Why Choose the Lovato P1MBUH2PC25 Miniature Circuit Breaker?

The Lovato P1MBUH2PC25 is a reliable two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the Lovato Electric P1MB modular circuit protection range, it provides dependable thermal magnetic protection for industrial machinery, automation equipment, electrical control panels and low-voltage distribution systems.

This miniature circuit breaker combines a 25 A rated current, Type C tripping characteristic and a high 10 kA short-circuit breaking capacity. The Type C response accommodates moderate temporary inrush currents, making the P1MBUH2PC25 suitable for circuits supplying transformers, power supplies, contactors, solenoids, small motors and other inductive electrical loads.

The P1MBUH2PC25 features a two-pole configuration, enabling both connected conductors to be disconnected simultaneously. It occupies two DIN modules and mounts onto a standard 35 mm DIN rail. Compliance with UL 489 and IEC/EN 60947-2 supports its use in internationally specified machinery, panel-building and industrial electrical applications.

Key Advantages

  • Dependable overload and short-circuit protection.
  • 25 A rated current for industrial control and power circuits.
  • Two-pole switching disconnects both conductors simultaneously.
  • Type C tripping characteristic accommodates moderate inrush currents.
  • High 10 kA short-circuit breaking capacity.
  • Conforms to UL 489 and IEC/EN 60947-2.

Key Features

  • Lovato Electric P1MB series.
  • Two-pole (2P) configuration.
  • 25 A nominal current rating.
  • Type C tripping curve.
  • 10 kA short-circuit breaking capacity.
  • 230/400 V AC IEC operational voltage.
  • 480Y/277 V AC UL operational voltage.
  • Compact two-module DIN rail design.

Reliable Two-Pole Circuit Protection

Miniature circuit breakers automatically disconnect an electrical circuit when excessive current is detected. This helps protect conductors, electrical components and connected equipment from damage caused by sustained overload conditions or short-circuit faults.

The Type C operating characteristic of the Lovato P1MBUH2PC25 allows moderate temporary inrush currents while maintaining dependable fault protection. Its two-pole construction is particularly suitable for installations where simultaneous isolation of both connected conductors is required.

Typical Applications

  • Industrial automation and control panels.
  • Machinery and OEM electrical systems.
  • Transformer and power supply circuits.
  • Contactors, relays and solenoid circuits.
  • Small motors and inductive electrical loads.
  • Commercial and industrial distribution boards.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Current 25 A
Phase Single Phase
Poles 2-pole
Device Type MCB
Trip Curve C curve
Breaking Capacity 10 kA
Manufacturer Lovato Electric
Series P1MB
Model P1MBUH2PC25
Product type Miniature circuit breaker
Number of poles 2P
Number of DIN modules 2
Rated current 25 A
Tripping characteristic Type C
Short-circuit breaking capacity 10 kA
Rated operational voltage (IEC) 230/400 V AC
Rated operational voltage (UL) 480Y/277 V AC
Rated operational voltage (DC) 125 V DC
Rated frequency 50 / 60 Hz
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Protection rating IP20
Mounting type 35 mm DIN rail
Tripping mechanism Thermal magnetic
Conformity UL 489 and IEC/EN 60947-2
Certifications cULus and EAC
GTIN 8013975220795
HS Code 85362010

Frequently Asked Questions

What is the Lovato P1MBUH2PC25 used for?

The P1MBUH2PC25 protects electrical circuits against overloads and short circuits in industrial machinery, control panels and low-voltage distribution systems.

What is the rated current of this circuit breaker?

The Lovato P1MBUH2PC25 has a nominal current rating of 25 A.

How many poles does the P1MBUH2PC25 have?

It is a two-pole miniature circuit breaker, allowing both connected conductors to be disconnected simultaneously.

What does the Type C tripping characteristic mean?

A Type C characteristic accommodates moderate temporary inrush currents, making the breaker suitable for transformers, power supplies, contactors, solenoids and small motors.

What is the breaking capacity of the P1MBUH2PC25?

The miniature circuit breaker provides a 10 kA short-circuit breaking capacity.

How is the P1MBUH2PC25 installed?

The breaker mounts onto a standard 35 mm DIN rail and occupies two DIN modules inside the electrical enclosure.

Trusted Industrial Circuit Protection

Lovato Electric miniature circuit breakers are used by panel builders, machine manufacturers and electrical engineers to provide dependable protection within industrial automation, machinery and electrical distribution applications.