Chint NL1-63-263/30-A RCD - 2P - Type A - 63A - 30mA

Chint NL1-63-263/30-A RCD – 2P – Type A – 63A – 30mA

Chint NL1-63-263/30-A residual current circuit breaker, a 63A 2 pole 30mA Type A RCCB designed for earth leakage and residual current protection in low voltage electrical installations.

SKU: NL1-63-263/30-AAlt SKU: NL16326330AMPN: NL1-63-263/30-A
Price
List Price £40.20 ex VAT
Your Price (ex VAT) Save 55%
£18.09 55% OFF
You save £22.11 per unit
In stock. Ships today if ordered before 2pm
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £18.09
Trade pricing is personalised to your account

6 in stock (can be backordered)

£18.09

Why Choose the Chint NL1-63-263/30-A RCCB?

The Chint NL1-63-263/30-A is a dependable residual current circuit breaker designed to provide earth leakage protection in low voltage electrical installations. As part of the Chint NL1-63 RCCB series, it detects residual current faults and disconnects the circuit when leakage current is present, helping improve electrical safety in domestic, commercial and light industrial distribution systems.

This model features Type A residual current protection, making it suitable for circuits where pulsating DC residual currents may occur. It is commonly used where modern electrical equipment, electronic power supplies, appliances and control devices are installed, offering enhanced protection compared with standard AC type RCCBs.

With a 63A rated current, 2 pole configuration and 30mA residual current sensitivity, the NL1-63-263/30-A is ideal for single-phase circuits requiring additional protection against electric shock and earth leakage faults.

Key Advantages

  • Compact RCCB designed for residual current protection.
  • 63A rated current suitable for distribution boards and final circuits.
  • 2 pole switching for single-phase installations.
  • 30mA residual current sensitivity for additional protection against electric shock.
  • Type A RCD detects AC and pulsating DC residual currents.
  • Suitable for modern domestic, commercial and light industrial electrical systems.

Key Features

  • Chint NL1-63 residual current circuit breaker series.
  • 63A rated operational current.
  • 2 pole configuration.
  • 30mA rated residual operating current.
  • Type A residual current protection.
  • Designed for low voltage AC electrical installations.
  • DIN rail mounted for easy installation in distribution equipment.
  • Compliant with recognised RCCB protection standards.

Reliable Type A Residual Current Protection

Residual current circuit breakers monitor the current flowing through live and neutral conductors. If an imbalance is detected, caused by leakage to earth, the RCCB trips and disconnects the circuit to help reduce the risk of electric shock and electrical fire.

The Type A protection of the Chint NL1-63-263/30-A makes it suitable for installations containing equipment that may generate pulsating DC residual currents, such as electronic appliances, control systems and modern power supplies. Its compact design allows straightforward integration into consumer units and distribution boards.

Typical Applications

  • Domestic consumer units.
  • Commercial distribution boards.
  • Final circuit protection.
  • Circuits with electronic equipment and appliances.
  • Light industrial electrical panels.
  • Earth leakage protection for low voltage circuits.

Technical Specifications

Tick the specs you need, then view products that match.

Current 63 A
Poles 2-pole
Residual Current 30 mA
RCD Type Type A
Device Type RCD
Manufacturer Chint
Series NL1-63
Model NL1-63-263/30-A
Product type Residual Current Circuit Breaker
Rated current 63A
Number of poles 2 Pole
Rated residual operating current 30mA
RCD Type Type A
Rated voltage 230 / 240V AC
Frequency 50 / 60Hz
Standard IEC/EN 61008-1
Mounting type DIN rail mounting
Application Residual current and earth leakage protection

Frequently Asked Questions

What is the Chint NL1-63-263/30-A used for?

It is used to provide residual current and earth leakage protection in low voltage electrical installations.

What current rating does this RCCB have?

The NL1-63-263/30-A has a rated current of 63A.

What does the 30mA rating mean?

The 30mA rating refers to the residual operating current sensitivity, meaning the device is designed to trip when earth leakage reaches approximately 30mA.

What does Type A mean on this RCD?

Type A means the device is designed to detect both sinusoidal AC residual currents and pulsating DC residual currents.

Does this RCCB provide overload protection?

No. An RCCB provides residual current protection only and should be used with suitable overcurrent protection such as an MCB or fuse.

Trusted by Electrical Professionals Worldwide