Chint NL1-63-216/10 residual current circuit breaker, a 16A 2 pole 10mA RCCB designed for earth leakage and residual current protection in low voltage electrical installations.
The Chint NL1-63-216/10 is a compact and reliable residual current circuit breaker designed to provide earth leakage protection in low voltage electrical installations. As part of the Chint NL1-63 RCCB series, it is used to detect residual current faults and disconnect the circuit when leakage current is present, helping improve electrical safety in domestic, commercial and industrial distribution systems.
The NL1-63 range is designed for circuit protection applications where protection against electric shock, indirect contact and fire risk from insulation faults is required. Its magnetic residual current operating principle provides dependable tripping performance without relying on an auxiliary supply, making it suitable for a wide range of distribution boards and consumer units.
With a 16A rated current, 2 pole configuration and 10mA residual current sensitivity, the NL1-63-216/10 is suitable for applications requiring highly sensitive earth leakage protection. It is ideal for final circuits, small loads and installations where fast disconnection is required to reduce the risk of electric shock.
Residual current circuit breakers monitor the balance of current flowing through live and neutral conductors. If an imbalance is detected, caused by leakage to earth, the RCCB trips and disconnects the circuit to help reduce the risk of electric shock and electrical fire.
The Chint NL1-63 series is suitable for use in housing, commercial buildings and industrial installations. Its compact modular design makes it easy to integrate into modern distribution boards while providing dependable residual current protection for electrical circuits and connected equipment.
Tick the specs you need, then view products that match.
| Current | 16 A | |
|---|---|---|
| Poles | 2-pole | |
| Residual Current | 10 mA | |
| Device Type | RCD | |
| Manufacturer | Chint | |
| Series | NL1-63 | |
| Model | NL1-63-216/10 | |
| Product type | Residual Current Circuit Breaker | |
| Rated current | 16A | |
| Number of poles | 2 Pole | |
| Rated residual operating current | 10mA | |
| Rated voltage | 240 / 415V AC | |
| Frequency | 50 / 60Hz | |
| Standard | IEC/EN 61008-1 | |
| Mounting type | DIN rail mounting | |
| Application | Residual current and earth leakage protection |
It is used to provide residual current and earth leakage protection in low voltage electrical installations.
The NL1-63-216/10 has a rated current of 16A.
The 10mA rating refers to the residual operating current sensitivity, meaning the device is designed to trip when earth leakage reaches approximately 10mA.
This model has a 2 pole configuration, making it suitable for single-phase circuits where both live and neutral are switched.
No. An RCCB provides residual current protection only and should be used with appropriate overcurrent protection such as an MCB or fuse.
Chint NL1-63 RCCBs are trusted by electricians, panel builders and contractors for reliable residual current protection, compact installation and dependable performance in low voltage distribution systems.