Chint NB310L-3N-B40 3P+N RCBO with 40A rated current, B Curve characteristic, Type A residual current protection, 30mA sensitivity and 6kA short circuit breaking capacity for three-phase electrical installations.
£60.04
The Chint NB310L-3N-B40 is a dependable 3P+N RCBO (Residual Current Circuit Breaker with Overcurrent Protection) designed to protect three-phase electrical circuits against earth leakage, overload and short circuit faults. Combining residual current protection and magnetic overcurrent protection in one compact unit, it helps improve electrical safety while saving space inside distribution boards and control panels.
As part of the Chint NB310L Series, this RCBO features a 40A rated current, B Curve tripping characteristic and Type A residual current protection. This makes it suitable for installations where protection is required against both sinusoidal AC residual currents and pulsating DC residual currents from modern electrical equipment.
With a 230/400V AC rated voltage, 30mA residual operating current and 6kA short circuit breaking capacity, the NB310L-3N-B40 is ideal for commercial and industrial low-voltage distribution systems requiring reliable combined circuit protection.
The Chint NB310L-3N-B40 provides essential protection for electrical installations by disconnecting the circuit when residual current, overload or short circuit conditions are detected. This helps protect personnel, cables and connected equipment while supporting compliance with modern low-voltage electrical safety requirements.
Its Type A residual current protection makes it particularly suitable for modern installations that include electronic loads, control equipment, power supplies and automation systems where pulsating DC leakage currents may be present.
Tick the specs you need, then view products that match.
| Poles | 3-pole + N | |
|---|---|---|
| Current | 40 A | |
| Phase | Three Phase | |
| Trip Curve | B curve | |
| Breaking Capacity | 6 kA | |
| Residual Current | 30 mA | |
| RCD Type | Type A | |
| Device Type | RCD | |
| Manufacturer | Chint | |
| Series | NB310L | |
| Model | NB310L-3N-B40 | |
| Product type | Residual Current Circuit Breaker with Overcurrent Protection | |
| Configuration | 3P+N | |
| Rated current | 40A | |
| Trip Curve | B Curve | |
| Residual current type | Type A | |
| Rated residual operating current | 30mA | |
| Rated voltage | 230/400V AC | |
| Frequency | 50/60Hz | |
| Rated short circuit breaking capacity | 6kA | |
| Rated insulation voltage | 500V | |
| Rated impulse withstand voltage | 4kV | |
| Protection rating | IP20 | |
| Mounting type | 35mm DIN rail | |
| Standard | IEC/EN 61009-1 |
The Chint NB310L-3N-B40 is used to protect three-phase circuits against overload, short circuit and earth leakage faults.
This model has a 40A rated current, making it suitable for selected three-phase distribution and equipment circuits.
B Curve devices are typically used for general electrical loads and trip between 3 and 5 times their rated current during magnetic fault conditions.
Type A protection detects sinusoidal AC residual currents and pulsating DC residual currents, making it suitable for many modern electrical installations.
The RCBO is designed for installation onto a standard 35mm DIN rail inside distribution boards and electrical control panels.