Chint NB310L-3N-B25 RCBO - 3P+N - B Curve - Type A - 25A - 30mA - 6kA

Chint NB310L-3N-B25 RCBO – 3P+N – B Curve – Type A – 25A – 30mA – 6kA

Chint NB310L-3N-B25 3P+N RCBO with 25A rated current, B Curve characteristic, Type A residual current protection, 30mA sensitivity and 6kA breaking capacity for commercial and industrial electrical installations.

SKU: NB310L-3N-B25Alt SKU: NB310L3NB25MPN: NB310L-3N-B25
Price
List Price £133.42 ex VAT
Your Price (ex VAT) Save 55%
£60.04 55% OFF
You save £73.38 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £60.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£60.04

Why Choose the Chint NB310L-3N-B25 RCBO?

The Chint NB310L-3N-B25 is a high-performance 3P+N RCBO (Residual Current Circuit Breaker with Overcurrent Protection) that combines earth leakage, overload and short circuit protection within a single compact device. Designed for commercial, industrial and three-phase electrical installations, it provides dependable circuit protection while reducing installation space and simplifying distribution board layouts.

As part of the trusted Chint NB310L Series, this RCBO features a 25A rated current, a B Curve magnetic trip characteristic and Type A residual current protection, making it suitable for modern electrical systems containing both AC and pulsating DC residual currents. Manufactured to IEC/EN 61009-1, it delivers reliable performance and enhanced electrical safety.

With its 230/400V AC operating voltage, 30mA residual operating current and 6kA short circuit breaking capacity, the NB310L-3N-B25 is ideal for protecting three-phase circuits supplying distribution equipment, machinery, commercial premises and industrial installations.

Key Advantages

  • Combined RCBO protection against overload, short circuit and earth leakage faults.
  • 25A rated current suitable for three-phase distribution circuits.
  • B Curve trip characteristic for resistive loads and general circuit protection.
  • Type A residual current detection for AC and pulsating DC leakage currents.
  • 30mA sensitivity provides additional protection for people.
  • Compact 3P+N DIN rail mounted design saves valuable panel space.

Key Features

  • Chint NB310L Series RCBO.
  • 25A rated current.
  • 3P+N configuration.
  • B Curve magnetic protection.
  • Type A residual current detection.
  • 30mA residual operating current (IΔn).
  • 6kA breaking capacity.
  • DIN rail mounting to EN 60715.

Reliable Protection for Three Phase Electrical Systems

The Chint NB310L RCBO protects electrical installations by combining miniature circuit breaker functionality with residual current protection in a single device. This simplifies installation while ensuring dependable protection against overloads, short circuits and earth leakage faults.

Its Type A residual current sensing allows detection of both alternating and pulsating DC fault currents, making it suitable for modern installations incorporating electronic equipment, automation systems and commercial electrical distribution.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial machinery and manufacturing equipment.
  • Three-phase power distribution systems.
  • Control panels and automation systems.
  • Building services and infrastructure.
  • Electrical installations requiring combined RCBO protection.

Technical Specifications

Tick the specs you need, then view products that match.

Poles 3-pole + N
Current 25 A
Phase Three Phase
Device Type RCBO
Trip Curve B curve
Breaking Capacity 6 kA
Residual Current 30 mA
RCD Type Type A
Manufacturer Chint
Series NB310L
Model NB310L-3N-B25
Product type RCBO
Configuration 3P+N
Rated current 25A
Trip curve B Curve
Residual current type Type A
Rated residual operating current 30mA
Rated voltage 230/400V AC
Frequency 50/60Hz
Breaking capacity 6kA
Protection rating IP20
Mounting type 35mm DIN rail
Standard IEC/EN 61009-1
Dimensions (H × W × D) approx. 86 × 72 × 77.5 mm

Frequently Asked Questions

What is the Chint NB310L-3N-B25 used for?

It provides combined protection against overloads, short circuits and earth leakage faults in three-phase electrical installations.

What does the B Curve characteristic mean?

B Curve devices are designed to trip between 3 and 5 times their rated current, making them suitable for resistive loads and general electrical circuits.

What does Type A residual current protection detect?

Type A RCBOs detect both sinusoidal AC and pulsating DC residual currents commonly found in modern electrical equipment.

What is the rated residual operating current?

The NB310L-3N-B25 has a 30mA residual operating current, providing additional protection against electric shock.

How is this RCBO installed?

The device is designed for quick installation onto a standard 35mm DIN rail inside electrical distribution boards and control panels.

Trusted by Electrical Professionals Worldwide

Chint NB310L RCBOs are trusted by electricians, panel builders and industrial engineers for dependable protection of modern three-phase electrical installations where safety, reliability and compliance are essential.