IMO B10C3N80A-L MCB - 3P+N - C Curve - 80A - 10kA

IMO B10C3N80A-L MCB – 3P+N – C Curve – 80A – 10kA

IMO B10C3N80A-L miniature circuit breaker with 80A rated current, C curve tripping characteristic, 3 Pole + Neutral left configuration and 10kA breaking capacity for industrial and commercial electrical protection.

SKU: B10C3N80A-LAlt SKU: B10C3N80ALMPN: B10C3N80A-L
Price
List Price £131.59 ex VAT
Your Price (ex VAT) Save 30%
£92.11 30% OFF
You save £39.48 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £92.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£92.11

Why Choose the IMO B10C3N80A-L Miniature Circuit Breaker?

The IMO B10C3N80A-L is a high-performance 10kA miniature circuit breaker (MCB) designed to protect electrical installations against overloads and short circuits in industrial, commercial and OEM applications. As part of the robust IMO B10 Series, it provides dependable overcurrent protection for demanding three-phase electrical systems.

Featuring a C curve tripping characteristic, this circuit breaker is suitable for circuits with moderate inrush currents, including lighting circuits, small motors, distribution boards and industrial control panels. Its 3 Pole + Neutral left-side neutral configuration makes it ideal for installations requiring neutral switching with the neutral positioned on the left.

With an 80A rated current, 3 Pole + Neutral (Left) arrangement and a 10kA short circuit breaking capacity, the B10C3N80A-L is well suited to industrial distribution boards, commercial switchgear and machinery control panels requiring reliable protection at higher load ratings.

Key Advantages

  • High performance 10kA miniature circuit breaker for industrial and commercial installations.
  • 80A rated current suitable for higher-load distribution circuits.
  • C curve tripping characteristic for circuits with moderate inrush currents.
  • 3 Pole + Neutral left-side configuration for three-phase electrical systems.
  • Compact DIN rail mounting for professional panel installation.
  • Designed for dependable protection against overloads and short circuits.

Key Features

  • IMO B10 Series miniature circuit breaker.
  • 80A rated current.
  • 3 Pole + Neutral (Left) configuration.
  • C curve tripping characteristic.
  • 10kA short circuit breaking capacity.
  • 240/415V AC rated operation.
  • TS35 DIN rail mounting.
  • Clear contact position indication with front labelling area.

Reliable Protection for Three-Phase Electrical Installations

Miniature circuit breakers automatically disconnect electrical circuits when overloads or short circuits occur. This helps protect wiring, connected loads and electrical equipment while improving safety across the installation.

The IMO B10 Series offers a higher 10kA fault rating, making it suitable for industrial and commercial environments where robust circuit protection and reliable disconnection performance are required.

Typical Applications

  • Three-phase distribution boards.
  • Industrial control panels.
  • Commercial electrical installations.
  • Machinery power distribution.
  • Lighting and motor circuits.
  • OEM electrical equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Current 80 A
Phase Three Phase
Poles 3-pole + N
Device Type MCB
Trip Curve C curve
Breaking Capacity 10 kA
Manufacturer IMO Precision Controls
Series B10 Miniature Circuit Breakers
Model B10C3N80A-L
Product type Miniature Circuit Breaker (MCB)
Rated current 80A
Tripping characteristic C Curve
Number of poles 3 Pole + Neutral
Neutral position Left
Rated voltage 240/415V AC
Frequency 50 / 60Hz
Breaking capacity 10kA
Mounting type TS35 DIN rail
Dimensions (H × W × D) approx. 85.5 × 70.3 × 78 mm
Standards IEC/EN 60898, IEC/EN 60947-2
HS Code 8536201090
Country of Manufacture China

Frequently Asked Questions

What is the IMO B10C3N80A-L used for?

The B10C3N80A-L is used to protect three-phase electrical circuits against overloads and short circuits in industrial, commercial and OEM applications.

What is the rated current?

This miniature circuit breaker has an 80A rated current.

What does the C curve tripping characteristic mean?

A C curve breaker is designed for circuits with moderate inrush currents, making it suitable for lighting, small motors and general industrial loads.

What does the left neutral configuration mean?

The neutral pole is positioned on the left-hand side of the breaker assembly for installations requiring a left-side neutral arrangement.

What is the breaking capacity?

The B10C3N80A-L provides a 10kA short circuit breaking capacity.

Trusted by Electrical Professionals Worldwide

IMO B10 miniature circuit breakers are trusted by electricians, panel builders and automation engineers for high-capacity overcurrent protection, compact installation and reliable long-term performance.