ABB DS-ARC1 M C6 A30 (2CSA275103R1064) arc fault detection device with integrated RCBO: 1P+N, C curve, 6 A, 10 kA breaking capacity, 30 mA Type A residual current.
£242.50
The ABB DS-ARC1 M C6 A30 is a compact and comprehensive arc fault detection device (AFDD) with integrated RCBO designed to protect low-voltage electrical circuits against dangerous arc faults, residual currents, overloads and short circuits. As part of the advanced ABB DS-ARC1 M series, it combines multiple protective functions within a single three-module device for residential, commercial and building electrical installations.
The DS-ARC1 M C6 A30 monitors the electrical circuit for characteristics associated with hazardous arc faults and disconnects the affected circuit when necessary. Its integrated residual current and overcurrent protection provides additional protection against earth leakage, overloads and short circuits, reducing the need for separate protective devices within the distribution board.
With a rated current of 6 A, a C tripping characteristic and 30 mA Type A residual current protection, the DS-ARC1 M C6 A30 provides comprehensive protection for suitable final circuits. The device operates at 230–240 V AC, offers a 10 kA ultimate short-circuit breaking capacity and uses a compact 1P+N configuration for DIN rail installation.
Arc faults can develop as a result of damaged conductors, deteriorated insulation, loose connections and other electrical installation faults. Some dangerous arcing conditions may not draw sufficient current to operate conventional overcurrent protection, so an AFDD monitors the circuit for electrical characteristics associated with hazardous arcs and disconnects the affected circuit when required.
The DS-ARC1 M series combines arc fault detection with RCBO functionality. This enables the DS-ARC1 M C6 A30 to provide protection against arc faults, residual currents, overloads and short circuits within one compact device, simplifying distribution-board design while providing multiple layers of electrical protection.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 6 A | |
| Trip Curve | C curve | |
| Breaking Capacity | 10 kA | |
| Phase | Single Phase | |
| Residual Current | 30 mA | |
| RCD Type | Type A | |
| Manufacturer | ABB | |
| Series | DS-ARC1 M | |
| Model | DS-ARC1 M C6 A30 | |
| Order code | 2CSA275103R1064 | |
| Product type | Arc fault detection device (AFDD) with integrated RCBO | |
| Rated current | 6 A | |
| Tripping characteristic | C | |
| Rated residual current | 30 mA | |
| Residual current type | Type A | |
| Rated operating voltage | 230–240 V AC | |
| Rated frequency | 50 / 60 Hz | |
| Number of poles | 1P+N | |
| Protected poles | 1 | |
| Ultimate short-circuit breaking capacity (Icu) | 10 kA | |
| Service short-circuit breaking capacity (Ics) | 7.5 kA | |
| Rated insulation voltage | 500 V | |
| Rated impulse withstand voltage | 4 kV | |
| Power loss | 2.5 W | |
| Standards | IEC/EN 62606, IEC/EN 61009-1, IEC/EN 61009-2-1 | |
| Mounting type | DIN rail mounting | |
| Terminal type | Screw terminals | |
| Terminal tightening torque | 2.8 N·m | |
| Terminal protection rating | IP20 | |
| Housing protection rating | IP40 | |
| Pollution degree | 2 | |
| Dimensions (H × W × D) | 85 × 52.5 × 69 mm | |
| Width | 3 modules / 52.5 mm | |
| Weight | approx. 0.24 kg | |
| Ambient operating temperature | -25 to +55 °C |
The ABB DS-ARC1 M C6 A30 is used to protect low-voltage electrical circuits against arc faults, residual currents, overloads and short circuits in residential, commercial and other building installations.
The device has a rated current of 6 A and uses a C tripping characteristic.
The device provides 30 mA Type A residual current protection, in addition to its arc fault, overload and short-circuit protection functions.
The ABB DS-ARC1 M C6 A30 has an ultimate short-circuit breaking capacity of 10 kA and a service short-circuit breaking capacity of 7.5 kA.
The device is designed for DIN rail mounting and occupies three modules, with an overall width of approximately 52.5 mm.
ABB DS-ARC1 M devices combine arc fault detection with residual current, overload and short-circuit protection, providing comprehensive protection within a compact DIN rail device for modern low-voltage electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.