ABB DS-ARC1 M C20 A30 (2CSA275103R1204) arc fault detection device with integrated RCBO: 1P+N, C curve, 20 A, 10 kA breaking capacity, 30 mA Type A residual current.
£242.50
The ABB DS-ARC1 M C20 A30 is a compact arc fault detection device (AFDD) with integrated RCBO protection designed to provide comprehensive protection for single-phase electrical circuits. As part of the ABB DS-ARC1 M series, it combines arc fault detection, residual current protection, overload protection and short-circuit protection within a single three-module DIN rail device.
The DS-ARC1 M is designed to protect against earth, parallel and series arc faults while its integrated Type A RCBO provides protection against earth fault currents, overloads and short circuits. The device also provides overvoltage protection, bringing several important electrical protection functions together within one compact unit.
With a rated current of 20 A, a C tripping characteristic and 30 mA Type A residual current sensitivity, the DS-ARC1 M C20 A30 provides enhanced protection for 1P+N circuits. Its 7.5 kA rated service short-circuit breaking capacity and 10 kA rated ultimate short-circuit breaking capacity make it suitable for installations requiring robust circuit protection, while the C-curve characteristic accommodates circuits with moderate starting or inrush currents.
Arc fault detection devices monitor electrical circuits for conditions associated with potentially dangerous electrical arcs. The ABB DS-ARC1 M is designed to protect against earth, parallel and series arc faults and combines this functionality with Type A residual current and thermal-magnetic overcurrent protection, enabling a single device to address multiple electrical fault conditions.
The DS-ARC1 M range combines AFDD and RCBO functionality with a 10 kA rated ultimate short-circuit breaking capacity while retaining a compact three-module format. This integrated approach reduces the number of separate protective devices required and provides protection against arc faults, residual currents, overloads, short circuits and overvoltage conditions within one DIN rail unit.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 20 A | |
| Trip Curve | C curve | |
| Breaking Capacity | 10 kA | |
| Phase | Single Phase | |
| Residual Current | 30 mA | |
| RCD Type | Type A | |
| Manufacturer | ABB | |
| Series | DS-ARC1 M | |
| Model | DS-ARC1 M C20 A30 | |
| Order code / MPN | 2CSA275103R1204 | |
| EAN | 8012542748014 | |
| Product type | Arc fault detection device with integrated RCBO | |
| Rated current | 20 A | |
| Tripping characteristic | C | |
| Rated residual current | 30 mA | |
| Residual current type | Type A | |
| Rated frequency | 50–60 Hz | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Rated service short-circuit breaking capacity (Ics) | 7.5 kA | |
| Rated ultimate short-circuit breaking capacity (Icu) | 10 kA | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 4 kV | |
| Pollution degree | 2 | |
| Mounting type | DIN rail | |
| Terminal type | Screw terminals | |
| Tightening torque | 2.8 N·m | |
| Modular width | 3 modules | |
| Dimensions (H × W × D) | 85 × 52.5 × 69 mm | |
| Weight | 240 g | |
| Standard | IEC/EN 62606 |
The ABB DS-ARC1 M C20 A30 is used to protect single-phase electrical circuits against arc faults, residual currents, overloads and short circuits using one integrated AFDD and RCBO device.
The device has a rated current of 20 A and uses a C tripping characteristic, making it suitable for circuits that can experience moderate starting or inrush currents.
The DS-ARC1 M C20 A30 provides Type A residual current protection with a rated residual current of 30 mA.
The DS-ARC1 M C20 A30 is designed to provide protection against earth, parallel and series arc faults, helping reduce risks associated with potentially dangerous electrical arcing.
The DS-ARC1 M C20 A30 has a 7.5 kA rated service short-circuit breaking capacity (Ics) and a 10 kA rated ultimate short-circuit breaking capacity (Icu).
ABB DS-ARC1 M devices combine arc fault detection with residual current and overcurrent protection in a compact DIN rail format, providing comprehensive circuit protection with enhanced short-circuit breaking capacity for modern electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.