ABB DS-ARC1 C20 A30 (2CSA255103R1204) arc fault detection device with integrated RCBO: 1P+N, C curve, 20 A, 6 kA breaking capacity, 30 mA Type A residual current.
£210.39
The ABB DS-ARC1 C20 A30 is a compact and highly reliable arc fault detection device (AFDD) with integrated RCBO protection designed to provide comprehensive protection for single-phase electrical circuits. As part of the advanced ABB DS-ARC1 series, it combines arc fault detection, residual current protection, overload protection and short-circuit protection within a single three-module DIN rail device.
This integrated protection solution is designed to protect against series, parallel and earth arc faults while also providing Type A residual current protection and thermal-magnetic overcurrent protection. The DS-ARC1 also provides overvoltage protection, bringing multiple protective functions together in one compact device for enhanced electrical safety and simplified distribution board design.
With a rated current of 20 A, a C tripping characteristic, 30 mA Type A residual current sensitivity and a 230–240 V AC rated operational voltage, the DS-ARC1 C20 A30 is suitable for single-phase circuits requiring enhanced protection. Its C-curve characteristic makes it suitable for circuits with moderate inrush currents, while its compact DIN rail format enables straightforward integration into electrical distribution boards.
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcs. The ABB DS-ARC1 is designed to protect against series, parallel and earth arc faults and combines this functionality with residual current and thermal-magnetic overcurrent protection, enabling a single device to provide protection against multiple electrical fault conditions.
The DS-ARC1 series is designed for modern electrical installations where comprehensive final-circuit protection is required. Its 1P+N configuration, Type A residual current protection, C-curve overcurrent characteristic and compact three-module DIN rail construction allow straightforward integration into compatible distribution boards while consolidating multiple protection functions into one device.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 20 A | |
| Trip Curve | C curve | |
| Breaking Capacity | 6 kA | |
| Phase | Single Phase | |
| Residual Current | 30 mA | |
| RCD Type | Type A | |
| Manufacturer | ABB | |
| Series | DS-ARC1 | |
| Model | DS-ARC1 C20 A30 | |
| Order code | 2CSA255103R1204 | |
| EAN | 8012542735113 | |
| Product type | Arc fault detection device with integrated RCBO | |
| Rated current | 20 A | |
| Tripping characteristic | C | |
| Rated residual current | 30 mA | |
| Residual current type | Type A | |
| Rated operational voltage | 230–240 V AC | |
| Rated frequency | 50–60 Hz | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Rated service short-circuit breaking capacity (Ics) | 6 kA | |
| Rated ultimate short-circuit breaking capacity (Icu) | 7.5 kA | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 4 kV | |
| Power loss | 4.2 W | |
| Protection rating | IP20 terminals / IP40 housing | |
| Pollution degree | 2 | |
| Operating temperature | -25 to +55 °C | |
| Contact position indication | Red ON / green OFF | |
| Actuator type | Toggle, orange RAL 2004, sealable in ON/OFF position | |
| Mounting type | DIN rail | |
| Terminal type | Screw terminals | |
| Tightening torque | 2.8 N·m | |
| Modular width | 3 modules | |
| Dimensions (H × W × D) | 85 × 52.5 × 69 mm | |
| Weight | 240 g | |
| Standards | IEC/EN 62606, IEC/EN 61009-1, IEC/EN 61009-2-1 |
The ABB DS-ARC1 C20 A30 is used to protect single-phase electrical circuits against arc faults, earth leakage currents, overloads and short circuits using one integrated AFDD and RCBO device.
The device has a rated current of 20 A and uses a C tripping characteristic, making it suitable for circuits that can experience moderate starting or inrush currents.
The DS-ARC1 C20 A30 provides Type A residual current protection with a rated residual current of 30 mA.
The DS-ARC1 C20 A30 has a rated operational voltage of 230–240 V AC and is designed for 1P+N single-phase electrical circuits.
The DS-ARC1 C20 A30 has a 6 kA rated service short-circuit breaking capacity (Ics) and a 7.5 kA rated ultimate short-circuit breaking capacity (Icu).
ABB DS-ARC1 devices combine arc fault detection with residual current and overcurrent protection in a compact DIN rail format, providing comprehensive circuit protection for modern residential and commercial electrical installations.