ABB DS-ARC1 C10 A30 (2CSA255103R1104) arc fault detection device with integrated RCBO: 1P+N, C curve, 10 A, 6 kA breaking capacity, 30 mA Type A residual current.
£210.39
The ABB DS-ARC1 C10 A30 is a compact and highly reliable arc fault detection device (AFDD) with integrated RCBO protection designed to provide comprehensive protection for single-phase electrical circuits. As part of the ABB DS-ARC1 series, it combines arc fault detection, residual current protection, overload protection and short-circuit protection within a single three-module DIN rail device.
This integrated protection solution detects potentially dangerous electrical arc faults while also providing Type A residual current protection and thermal-magnetic overcurrent protection. The DS-ARC1 series incorporates self-testing of its arc fault detection functionality and provides front-panel indication, helping deliver reliable protection while simplifying fault identification.
With a rated current of 10 A, a C tripping characteristic and 30 mA Type A residual current sensitivity, the DS-ARC1 C10 A30 is designed for 230–240 V AC 1P+N circuits. Its C-curve characteristic makes it suitable for circuits with moderate inrush currents while its compact DIN rail format enables straightforward integration into electrical distribution boards.
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcs. The ABB DS-ARC1 combines this functionality with residual current and thermal-magnetic overcurrent protection, enabling a single device to provide protection against arc faults, earth leakage currents, overloads and short circuits.
The DS-ARC1 series is designed to simplify the implementation of enhanced electrical protection in modern distribution systems. Its self-testing AFDD functionality, 1P+N configuration, compact three-module construction and DIN rail mounting allow straightforward integration into compatible electrical distribution boards while providing multiple protection functions from one device.
Tick the specs you need, then view products that match.
| Device Type | AFDD | |
|---|---|---|
| Poles | 1-pole + N | |
| Current | 10 A | |
| Trip Curve | C curve | |
| Breaking Capacity | 6 kA | |
| Phase | Single Phase | |
| Residual Current | 30 mA | |
| RCD Type | Type A | |
| Manufacturer | ABB | |
| Series | DS-ARC1 | |
| Model | DS-ARC1 C10 A30 | |
| Order code | 2CSA255103R1104 | |
| Product type | Arc fault detection device with integrated RCBO | |
| Rated current | 10 A | |
| Tripping characteristic | C | |
| Rated residual current | 30 mA | |
| Residual current type | Type A | |
| Rated operational voltage | 230–240 V AC | |
| Rated frequency | 50–60 Hz | |
| Number of poles | 1P+N | |
| Number of protected poles | 1 | |
| Rated service short-circuit breaking capacity (Ics) | 6 kA | |
| Rated ultimate short-circuit breaking capacity (Icu) | 7.5 kA | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 4 kV | |
| Power loss | 1.8 W | |
| Protection rating | IP20 terminals / IP40 housing | |
| Pollution degree | 2 | |
| Operating temperature | -25 to +55 °C | |
| Contact position indication | Red ON / green OFF | |
| Mounting type | DIN rail | |
| Terminal type | Screw terminals | |
| Tightening torque | 2.8 N·m | |
| Modular width | 3 modules | |
| Dimensions (H × W × D) | 85 × 52.5 × 69 mm | |
| Weight | 240 g | |
| Standards | IEC/EN 62606, IEC/EN 61009-1, IEC/EN 61009-2-1 |
The ABB DS-ARC1 C10 A30 is used to protect single-phase electrical circuits against arc faults, earth leakage currents, overloads and short circuits using one integrated AFDD and RCBO device.
The device has a rated current of 10 A and uses a C tripping characteristic.
The DS-ARC1 C10 A30 provides Type A residual current protection with a rated residual current of 30 mA.
The device has a rated operational voltage of 230–240 V AC and is designed for 1P+N single-phase circuits.
The DS-ARC1 C10 A30 has a 6 kA rated service short-circuit breaking capacity (Ics) and a 7.5 kA rated ultimate short-circuit breaking capacity (Icu).
ABB DS-ARC1 devices combine arc fault detection with residual current and overcurrent protection in a compact DIN rail format, providing comprehensive circuit protection for modern electrical installations.