Chint NL1-63-225/100 residual current device, a 25 A 100 mA 2 pole AC type RCD designed for earth leakage protection in consumer units, distribution boards and electrical installations.
£18.80
The Chint NL1-63-225/100 is a reliable residual current device (RCD) designed to provide earth leakage protection in residential, commercial and light industrial electrical installations. As part of the Chint NL1 RCCB series, it automatically disconnects the circuit when residual current faults are detected, helping protect people and property from electric shock and fire hazards.
This device is a 2 pole, AC type RCD suitable for detecting sinusoidal alternating residual currents. It is commonly used within consumer units, distribution boards and control panels where dependable residual current protection is required without integrated over-current protection.
With a rated current of 25 A and a residual operating current of 100 mA, the NL1-63-225/100 is suitable for circuits requiring earth leakage protection at a higher sensitivity level than standard fault protection. Its DIN rail mounting format enables straightforward installation in modern electrical enclosures.
Residual current devices such as the Chint NL1-63-225/100 monitor the difference between live and neutral current. If an imbalance is detected, the device disconnects the circuit to help prevent dangerous electric shock and reduce the risk of fire caused by insulation faults.
The NL1 series is designed for residual current protection only and should be used alongside suitable over-current protection, such as an MCB or fuse, where required. Its compact DIN rail design makes it suitable for modern consumer units, distribution boards and industrial electrical panels.
Tick the specs you need, then view products that match.
| Current | 25 A | |
|---|---|---|
| Poles | 2-pole | |
| Device Type | RCD | |
| Residual Current | 100 mA | |
| Manufacturer | Chint | |
| Series | NL1-63 | |
| Model | NL1-63-225/100 | |
| Product type | Residual current device / RCCB | |
| Number of poles | 2 pole | |
| Rated current | 25 A | |
| Residual operating current | 100 mA | |
| Tripping type | AC type | |
| Rated voltage | 230 V AC | |
| Rated frequency | 50 / 60 Hz | |
| Rated conditional short-circuit current | 6 kA | |
| Rated insulation voltage | 500 V | |
| Rated impulse withstand voltage | 4 kV | |
| Mounting type | 35 mm DIN rail | |
| Protection rating | IP20 | |
| Operating temperature | approx. -25 to +70°C | |
| Standards | IEC / EN 61008-1 |
The Chint NL1-63-225/100 is used to provide residual current protection by disconnecting the circuit when earth leakage faults are detected.
The Chint NL1-63-225/100 has a rated current of 25 A.
This RCD has a residual operating current of 100 mA.
The device has a 2 pole configuration, making it suitable for single-phase live and neutral disconnection.
No, the NL1-63-225/100 provides residual current protection only and should be used with suitable over-current protection where required.
Chint residual current devices are widely used by electrical contractors, panel builders and maintenance engineers to provide dependable earth leakage protection in residential, commercial and industrial electrical systems.